Pathology Lab Report Template Maker
Lab report layouts for CBC, lipid profile, urine R/E and thyroid tests: you set the ranges and limits, results outside them are flagged and coloured.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Set up the header
Enter the laboratory name, address and licence or accreditation line.
- 2Load a panel
Pick the CBC, lipid, urine or thyroid preset as a starting table.
- 3Enter your ranges
Replace the example reference and critical limits with your validated ones.
- 4Fill the patient block
Add the patient, referring doctor, specimen and collection times.
- 5Type the results
Enter each result and check the flags in the preview.
- 6Sign and print
Add the pathologist's comment, print the report and sign it.
About this tool
Small laboratories and clinic labs often type reports in a word processor, copying a previous patient's file, changing the numbers and hoping nobody forgets to update a range or a flag. This template maker produces a clean one-page report from a table you control. The header carries the laboratory name, address and licence or accreditation line. A patient block shows name, age and sex, the lab ID, the referring doctor, the specimen and the collection and reporting times. The results table is grouped by section, such as haematology, biochemistry or urine physical, chemical and microscopic, and each row holds the test, the result, the unit, a reference low and high, an expected text finding for non-numeric tests, and optional critical low and high limits. The report compares each result only with the limits typed in that row: below the range is marked L, above is H, beyond a critical limit is LL or HH on a red badge, and a text result that differs from the expected finding, such as Trace where Nil is expected, gets an A. Flagged results are printed in red, and a legend under the table explains the letters. A comment box holds whatever the pathologist writes, and two signature lines cover the technologist and the consultant pathologist, with a footer note about the specimen and ranges. Presets load a complete blood count with ESR, fasting glucose with lipid profile, urine routine examination and thyroid function. The example ranges are placeholders to replace with your own validated ones, and the flags are a numeric comparison, not an interpretation of the results.
Setting your own ranges
Reference intervals depend on the analyser, the method and the population, which is why accreditation standards expect each laboratory to state its own. Replace the example numbers with your validated ranges. Leave the low limit blank for a value with only an upper bound, such as total cholesterol below 200 mg/dL, and it prints as "below 200". For text tests, put the normal finding in the expected text column.
Critical limits
Critical values are results far enough outside the range that the laboratory usually phones the doctor at once. Enter them where your procedure defines them. Any result beyond a critical limit is listed separately under the preview as a reminder to follow your call-out procedure.
Worked example
Load the CBC preset. Of 12 tests, five are flagged against the example ranges: haemoglobin 10.8 g/dL against 12 to 15.5 is marked L, a white cell count of 11,800 per µL is H, PCV 33% is L, MCH 26.3 pg is L and ESR 28 mm in the first hour is H. Change haemoglobin to 6.5 and, with a critical low of 7, it becomes LL. In the urine preset an albumin result of Trace where Nil is expected is marked A.
Printing and saving
Each report prints on one A4 page or downloads as a Word file. Save a report as JSON or duplicate it to keep the same ranges for the next patient and only change the results and patient details.
Limits
The tool does not connect to analysers, calculate derived values or keep a patient database. It does not interpret results or suggest a diagnosis, and a flag means only that a number is outside the limits you typed. Reports must be checked and authorised by qualified staff under your laboratory's quality system.
Worked example
Haemoglobin 10.8 g/dL with your range 12 to 15.5 prints as "10.8 L"; with a critical low of 7, a result of 6.5 prints "LL".
Quick facts
- Category: Health & Fitness
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: ISO 15189 medical laboratory report content (reference intervals, flags, authorisation)
Frequently asked questions
Are the reference ranges in the presets official?
No. They are typical example values to show the layout. Replace them with the ranges your laboratory has validated for its own analyser and population.
What do L, H, LL, HH and A mean?
L and H are below and above your reference range, LL and HH are beyond your critical limits, and A means a text result differs from the expected finding.
Can I add my own tests?
Yes. Add rows with a section name, test, unit and limits. Rows with the same section appear together under one heading.
Does the report explain what a result means?
No. It prints the result, the range and a flag. Any comment comes only from the pathologist's own text in the comment box.
How do I report a test with only an upper limit?
Leave the reference low blank and fill the high value. The range prints as below that number and only higher results are flagged.
Is patient data uploaded?
No. The report is built and saved in this browser. Print it or download the Word file to share it.