U-Value Calculator for Walls, Roofs and Floors
Calculate the U-value of a building element from its layers and the heat it loses.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Step 1: Open U-Value Calculator for Walls, Roofs and Floors and add your input
Type your numbers or text, add your file, or pick the options you need. Nothing is uploaded: everything stays in your browser.
- 2Step 2: What U-Value Calculator for Walls, Roofs and Floors does
Calculate the U-value of a building element from its layers and the heat it loses.
- 3Step 3: Read the result and compare
The result appears at once. Change one value to see how the answer moves, then keep the figure that fits your case.
- 4Step 4: Copy or save it
Copy the result or download it. For an important decision, confirm it with the official source or an adviser.
About this tool
Enter each layer on its own line: name, thickness in millimetres and thermal conductivity in W/mK. Choose a wall, roof or floor. The calculator adds the thermal resistances and surface resistances, gives the U-value and the heat loss for your area and temperature difference.
How it works
Each layer has a resistance R = thickness in metres ÷ conductivity. The total resistance is the sum of the layers plus the inside and outside surface resistances (walls 0.13 and 0.04, roofs 0.10 and 0.04, floors 0.17 and 0.04 m²K/W). The U-value is 1 ÷ total resistance in W/m²K.
Heat loss
Heat loss in watts is U × area × temperature difference. The yearly figure assumes 200 heating days at the same difference all day, a rough estimate.
Limits
The method ignores thermal bridges such as studs and mortar joints, ventilated cavities and moisture. For compliance use the full calculation method in your building code.
Worked example
A cavity wall of 102 mm brick (0.77), 100 mm insulation (0.032), 100 mm block (0.19) and 13 mm plaster (0.57) has a layer resistance of 3.807 m²K/W, a total of 3.977 with surface resistances and a U-value of 0.251 W/m²K. For 50 m² and a 20 K difference the loss is 251 W.
Tips for best results
Check every box before you rely on a result, because one wrong digit changes the whole answer. Use the exact figures from your payslip, bill, certificate or contract, and keep a note of the date you calculated. Rates, thresholds and rules change from time to time, so for tax, fees and legal matters treat the output as an estimate and confirm with the official source named on this page. You can run as many scenarios as you like; nothing is saved or sent, and refreshing the page clears the boxes.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in many languages.
- Content last reviewed:
Frequently asked questions
Where do I find conductivity values?
In manufacturers' data sheets or tables such as CIBSE or EN ISO 10456.
What is a good U-value?
Modern walls are around 0.15 to 0.3 W/m²K, roofs lower; check your local building regulations.
Does it include air gaps?
Add an unventilated air gap as a layer with its resistance as thickness ÷ conductivity, such as 0.18 m²K/W.
Why use thickness in mm?
It matches how layers are specified; the tool converts to metres.