CPAP Data Viewer (ResMed SD Card)
Put the SD card from your ResMed machine in a reader and open its folder. The viewer reads STR.edf and the DATALOG night files and shows usage hours, the AHI the machine recorded, leak, mask pressure, respiratory rate and each event, with a monthly table, notes per night and a printable report.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Copy or insert the card
Put the SD card in a card reader, or copy the whole card to a folder on your computer.
- 2Open the folder
Tap Open SD card folder and choose the top folder that holds STR.edf and DATALOG.
- 3Pick a date range
Set From and To; the overview shows usage, device AHI, leak and pressure for every night.
- 4Open a night
Tap a bar or choose a night to see pressure, leak, breathing rate and event bands; load the 25 Hz flow if you want it.
- 5Add notes
Type a note for the night, such as mask changes; undo works on notes and settings.
- 6Export
Print the report as PDF or save the nights and the monthly table as CSV.
About this tool
ResMed AirSense 10, AirSense 11 and AirCurve machines save their data on a small SD card in the European Data Format. The card holds a file called STR.edf with one summary record per day, an Identification file with the model and a DATALOG folder with one sub-folder per night. Each night folder can contain a BRP file with the breathing flow and pressure sampled 25 times a second, a PLD file with slower values such as leak, mask pressure, respiratory rate, tidal volume, snore and flow limitation, an EVE file listing every apnoea, hypopnoea and arousal the machine flagged and, with an oximeter attached, an SA2 file with SpO2 and pulse. This tool reads all of these in your browser. Pick the top folder of the card and it builds a table of nights from STR.edf: minutes of use, the AHI and its parts (obstructive, central, unclassified and hypopnoea indices), median and 95th percentile leak and pressure, and the mode and set pressures. Tap any night to open its detail charts, with events drawn as coloured bands so you can see when they happened during the night. Leak is shown in litres per minute by default; the card stores litres per second and you can switch back. A monthly table, notes for each night and a printable report with charts make it easy to keep a record or bring a summary to an appointment.
What the numbers are
Every value comes from the machine. The AHI in the overview and in each night is the figure the device wrote to STR.edf. In the night view the tool also counts the apnoea and hypopnoea events listed in the EVE files and divides by the hours of data, so you can check that the two agree; small differences are normal because the machine applies its own rules. Usage counts the mask-on minutes recorded for the day, which runs from noon to noon.
Supported cards
EDF-based ResMed models: AirSense 10 (AutoSet, Elite, CPAP, For Her), AirSense 11 and AirCurve 10 (VAuto, ASV, S). Older S9 cards use similar files and often work. Philips, Fisher and Paykel and other brands use different formats and are not supported. The mode number is shown as a name only for CPAP and AutoSet; other codes are listed as numbers because they differ by model.
Privacy
The card contains your serial number and the times you slept. Nothing is uploaded; the files are read with JavaScript in this tab, and notes are kept in this browser until you save them as a file.
Limits
This is not a medical device and it does not diagnose sleep apnoea, judge whether a therapy works or recommend a pressure. Do not change the settings of your machine because of anything shown here. Take questions about your numbers, mask fit or comfort to your sleep clinic or doctor.
Worked example
A user opens the card of an AirSense 10 AutoSet. STR.edf covers 30 days and 27 nights show use. The overview gives an average of 6:48 hours on used nights, 25 nights of at least 4 hours, a median device AHI of 1.9 events per hour, a median 95 percent leak of 14.4 L/min (0.24 L/s on the card) and a median 95 percent pressure of 10.6 cmH2O. On 14 March the AHI reads 4.2; the night view shows 7 obstructive apnoeas, 2 central apnoeas and 21 hypopnoeas in 7.1 hours of data, which recounts to 4.2 per hour, and a leak spike from 03:10 to 03:40. The user adds the note "new cushion, strap loose" to that night and prints the 30-day report for the next clinic visit.
Quick facts
- Category: Health & Fitness
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: European Data Format (EDF and EDF+, Kemp et al.) as written by ResMed AirSense and AirCurve machines; a viewer of recorded data, not for diagnosis or treatment
Frequently asked questions
Will this tell me if my therapy is working?
No. It shows the values your machine recorded, such as AHI, leak and usage, but deciding whether therapy is effective needs your clinician, who also considers symptoms and other tests. Bring the report to your appointment rather than drawing conclusions from the charts.
Which folder should I open?
The top folder of the SD card, the one that contains STR.edf, Identification.tgt or Identification.json and the DATALOG folder. Browsers ask for permission to read a folder; the files stay on your device. You can also select STR.edf alone for the daily summary.
Why is my leak shown as 14 when the machine says 0.24?
ResMed stores leak in litres per second. Most charts and clinicians use litres per minute, so the tool multiplies by 60. Untick the L/min box to see the raw value from the card.
Why do the detail charts not appear for some nights?
The night view needs the DATALOG files for that date. Machines keep a limited history on the card and some settings record only the summary. Nights that appear only in STR.edf are marked summary only.
Does it work with an AirSense 11 card?
Yes, AirSense 11 still writes EDF files with the same signal names in most cases, and its Identification.json is read for the model name. If a signal is missing on your model, its chart is simply left out.
Can I change my machine settings with this?
No. The viewer only reads the card and never writes to it. Settings must be changed by your equipment provider or clinician on the machine itself.
