Tolerance Stack-Up Calculator
List each dimension with nominal, plus and minus tolerance and direction, enter the requirement and measurement data to get worst-case and statistical stack-ups and checks.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Draw the loop
Decide directions.
- 2Fill the table
Nominal, plus, minus and direction.
- 3Enter the requirement
Allowed ± on the result.
- 4Enter measurement data
Uncertainty, bias and drift readings.
- 5Read the stack
Worst case, RSS and checks.
About this tool
When parts are assembled, their dimensional tolerances add up along a chain of dimensions, and the resulting gap or overall length must still meet its requirement. Engineers check this with a tolerance stack-up. The worst-case method guarantees every assembly fits but can force tight, costly tolerances; the root-sum-square (RSS) method uses statistics to allow wider part tolerances. This calculator does both, handles asymmetric tolerances and directions, and adds metrology checks: guard bands, bias and drift.
Who this is for
Mechanical design engineers, quality engineers, toolmakers and students of engineering design and GD&T.
Setting up the chain
Draw a loop from one side of the gap to the other. Each dimension that pushes the gap larger is positive (+1), each that makes it smaller negative (−1). Enter nominal, plus tolerance, minus tolerance (as a positive number) and direction.
Asymmetric tolerances
A dimension 10 +0.2/−0.0 is converted to its mean 10.1 ± 0.1. The stack uses means and symmetric half-widths, so the centre of the result may differ from the nominal sum.
Worst case
T_wc = Σ |t_i|. Every assembly built from in-tolerance parts is guaranteed within this range. Use it for safety-critical fits and small production runs.
Root sum square
T_rss = √Σ t_i². If dimensions are independent, centred and normally distributed with tolerances at the same sigma level, about 99.73 % of assemblies fall within it. It is always smaller than worst case; the ratio shows how much is gained.
Checking the requirement
Enter the allowed ± variation of the result to see whether worst case or RSS meets it.
Guard bands
When measuring the finished assembly, measurement uncertainty U can make a conforming part look non-conforming or the reverse. Guard banding narrows the acceptance limits by U (ISO 14253-1 for conformity), reducing the risk of accepting bad parts.
Bias and drift
Bias is the difference between a gauge's reading and the reference value, often given as a percentage. Drift is the change of a reading over time, used to set calibration intervals.
Good practice
Use RSS only for large production volumes with capable processes (Cpk ≥ 1.33). Consider a correction factor (Bender's 1.5) when distributions are uncertain.
Keep the loop diagram with the drawing so that design reviews can check every link.
Worked example
Dimensions of 10 ± 0.1 and 20 ± 0.2 (positive) and 5 ± 0.05 (negative) give a nominal of 25. Worst case is ± 0.35, RSS ± 0.229, 65 % of the worst case. With a requirement of ± 0.3, only the RSS method meets it. With U = 0.02, acceptance limits are ± 0.28.
Limits
One-dimensional linear stacks; angular and geometric tolerances need 3D analysis. Not a substitute for official drawing standards.
Worked example
10 ± 0.1 + 20 ± 0.2 − 5 ± 0.05 stacks to 25 ± 0.35 worst case or ± 0.23 RSS.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: Linear tolerance stack-up: worst case T = Σ
Frequently asked questions
What is a tolerance stack-up?
The accumulation of part tolerances along a chain of dimensions.
What is the difference between worst case and RSS?
Worst case adds all tolerances; RSS adds them statistically.
When should I use RSS?
For large volumes with capable, centred processes.
How do I handle asymmetric tolerances?
Convert to the mean dimension and a symmetric half-width.
What is a guard band?
A reduction of acceptance limits by the measurement uncertainty.
Is my data stored?
No. Everything is calculated in your browser.