Tolerance Stack-Up Analysis: Worst Case versus RSS
How to set up a tolerance stack-up loop, calculate worst-case and RSS results, handle asymmetric tolerances, and use guard bands when measuring assemblies.

Tolerance Stack-Up Analysis: Worst Case versus RSS
Parts are never made to exact size. When several parts are assembled, their small deviations add up, and the critical gap or overall length of the assembly can end up out of specification even though every part is within tolerance. Tolerance stack-up analysis predicts this. This guide explains the two main methods and how to choose, and you can analyse a chain with the tolerance stack-up calculator.
Setting up the loop
- Identify the requirement: a gap, a clearance or an overall dimension.
- Draw a loop from one side of it to the other, following the dimensions on the parts.
- Give each dimension a direction: + if it makes the requirement larger, − if smaller.
Asymmetric tolerances
A dimension such as 10 +0.2 / −0.0 is not centred. Convert it to its mean (10.1) with a symmetric tolerance (± 0.1). The stack is computed with means and symmetric half-widths, so the mean result can differ from the nominal sum.
Worst-case method
Add all tolerances:
T_wc = Σ |t_i|.
If every part is within tolerance, every assembly is guaranteed within the worst-case limits. This is the safe choice for safety-critical fits, small batches and processes you do not control.
Root-sum-square method
If dimensions vary independently and are normally distributed and centred, extreme combinations are rare. The statistical tolerance is:
T_rss = √Σ t_i².
With tolerances set at ± 3 sigma, about 99.73 % of assemblies fall within T_rss. Because it is always smaller than worst case, RSS lets designers loosen part tolerances and save cost.
Example
| Dimension | Tolerance | Direction |
|---|---|---|
| 10 | ± 0.10 | + |
| 20 | ± 0.20 | + |
| 5 | ± 0.05 | − |
Nominal result 25. Worst case ± 0.35; RSS ± 0.23, about 65 % of the worst case. If the requirement is 25 ± 0.3, only the statistical method meets it.
When RSS is risky
- Few parts in the stack: the statistical benefit is small.
- Processes that are not centred or not capable (Cpk below 1.33).
- Dimensions that are correlated, for example made in the same fixture.
- Very small production runs.
Some companies use a compromise such as a Bender factor of 1.5 times the RSS value, or Monte Carlo simulation with real process distributions.
Measuring the assembly: guard bands
When you measure the finished assembly, the measurement uncertainty U blurs the decision. ISO 14253-1 recommends narrowing the acceptance zone by U for proving conformity. With a requirement of ± 0.30 and U = 0.02, accept only within ± 0.28.
Bias and drift
Gauges also have systematic errors. Bias is the difference between the average reading and the reference value. Drift is how a reading changes over time, and helps set calibration intervals.
Good practice
- Keep the loop diagram with the drawing.
- Check that geometric tolerances (position, flatness) that affect the loop are included.
- Re-run the stack when tolerances change.
Using the calculator
- Enter each dimension: nominal, plus tolerance, minus tolerance and direction.
- Enter the allowed variation of the result.
- Enter the measurement uncertainty, measured and reference values, and two readings over time.
- Read worst-case and RSS ranges, the requirement check, guard-banded limits, bias and drift.
Monte Carlo simulation
For complex assemblies, Monte Carlo simulation draws thousands of random part sizes from realistic distributions, including skewed or shifted ones, and builds a histogram of the result. It is the most realistic method but needs good process data.
Reducing a critical stack
If the stack fails, look for the largest tolerance in the loop, shorten the loop by changing the design, or add an adjustment such as a shim or slotted hole.
Limits
The calculator handles one-dimensional linear stacks. Angular stacks and 3D geometric tolerances need specialised software.