Septic Tank and Drain Field Size Calculator

Enter bedrooms or occupants and your perc test result to estimate tank volume, absorption area, trench lines, rock or chambers and pump-out timing.

ทำงานในเบราว์เซอร์ของคุณ ไฟล์ไม่ออกจากอุปกรณ์ ดูวิธีตรวจสอบ

…

วิธีทำ

  1. 1
    Choose the flow basis

    Pick bedrooms or occupants and enter the design flow per bedroom or person.

  2. 2
    Set the tank rule

    Choose days of flow with a minimum, or a base size plus an amount per extra bedroom.

  3. 3
    Enter the soil

    In Soil and field, enter the percolation rate and check the loading-rate table.

  4. 4
    Lay out trenches

    Set trench width, longest line, spacing, reserve and gravel or chambers.

  5. 5
    Check the plan

    Open Field plan to see trench lines and the reserve area.

  6. 6
    Cost and log

    Enter prices for the cost list and record inspections and pump-outs in the log.

เกี่ยวกับเครื่องมือนี้

A septic system has two parts that are sized separately. The tank holds wastewater long enough for solids to settle and scum to float, and the drain field (leach field) spreads the clarified effluent into soil that can absorb and treat it. Health departments size both from a design flow, usually counted per bedroom rather than per person because a house may later hold more people, and from how fast water soaks into the soil in a percolation test. This calculator walks through that method. Choose bedrooms or occupants and a design flow, pick a tank rule (a number of days of flow with a minimum size, or a base size plus an amount for each extra bedroom), and add the extra volume many codes require for a kitchen garbage disposal. Enter the percolation rate in minutes per inch and the tool finds the loading rate from an editable table, the absorption area, the total trench length, the number of lines within your longest-line limit, the field footprint and a reserve area. It also estimates drain rock or leaching chambers, rough costs and a pump-out interval, and keeps a maintenance log.

Design flow and tank

Many codes assume about 150 US gallons per bedroom per day. With the default rule the tank holds two days of design flow with a 1,000 gallon minimum, and the first compartment takes about two thirds. The alternative rule mimics codes that set a base tank for up to three bedrooms and add a fixed amount for each extra bedroom. Change any number to match your local code.

Soil and field

The loading rate is the gallons per square foot per day the soil can accept. The default table follows the example rates in an EPA design manual: faster soils accept more, slow clays less, and soils faster than 1 minute per inch or slower than the last band need a special design. Trench bottom area is what counts, so area divided by trench width gives total trench length.

Pump-out estimate and log

Solids build up at roughly 15 to 25 US gallons per person per year. The tool estimates when they reach a third of the tank. Log inspections with sludge and scum depths and pump-outs with costs; the next due date follows the last pump-out. Import or export the log as CSV.

Limits

This is a planning estimate, not a design. Only a licensed designer or the health department can size and permit a system after a site evaluation, soil tests and setback checks from wells, water and property lines. Mound, pressure-dosed and advanced treatment systems follow different rules that are not covered.

ตัวอย่างพร้อมวิธีทำ

A 3-bedroom house at 150 gallons per bedroom has a design flow of 450 gallons a day. Two days of flow is 900 gallons, so the 1,000 gallon minimum applies, with about 670 gallons in the first compartment. A perc test of 20 minutes per inch falls in the 16 to 30 band at 0.6 gallons per square foot per day, so the field needs 750 square feet of trench bottom. With 3 foot trenches that is 250 feet, laid as 3 lines of about 83 feet with 6 feet between trenches, a footprint of 83 by 21 feet plus an equal reserve area. At 12 inches of rock the trenches take about 28 cubic yards. Four people adding 18.5 gallons of solids a year fill a third of the tank in about 4.5 years.

สรุปสั้น ๆ

คำถามที่พบบ่อย

How big a septic tank do I need for 3 bedrooms?

Many codes require at least 1,000 US gallons for up to three bedrooms. With 150 gallons per bedroom and two days of storage the rule also gives 900 gallons, so the minimum controls.

What is a percolation rate?

It is how many minutes the water level in a test hole drops by one inch after soaking. Fast-draining sand might be 3 minutes per inch, dense clay 60 or more. Your health department specifies how to run the test.

Why does the tool size by bedrooms?

Occupancy changes when a house is sold or a family grows, so codes use bedrooms as a stable proxy for the most people likely to live there. Switch to occupants if your code allows it.

How often should a septic tank be pumped?

EPA guidance says household tanks are typically pumped every three to five years and inspected by a professional at least every three years. Measuring sludge and scum is the real test; the estimate is only a starting point.

What is a reserve area?

Land kept free for a replacement field if the first one fails. Many codes require an area equal to the original field; set 0 if yours does not.

Can I use litres and metres?

Yes. Switch to metric and flows, tank sizes, trench sizes and loading rates (litres per square metre per day) are converted. Percolation stays in minutes per inch because most test forms use it.

ฟรีทั้งหมดไม่มีค่าใช้จ่าย ไม่ต้องสมัคร