Radiation Dose and Shielding Calculator
Enter deposited energy, mass and radiation type, a shielding material and thickness, and a dose rate at a distance to get dose, transmission, HVL and new dose rates.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Enter energy and mass
Deposited energy and body mass.
- 2Choose radiation type
Neutron energy if needed.
- 3Choose shielding
Material or custom μ, and thickness.
- 4Enter dose rate and distances
For the inverse-square law.
- 5Read the results
Dose, transmission and rates.
About this tool
Radiation protection uses three quantities: absorbed dose in gray (energy per kilogram), equivalent dose in sievert (weighted for the type of radiation) and effective dose (weighted for the organs exposed). Protection relies on time, distance and shielding. This calculator computes absorbed and equivalent dose with the ICRP 103 weighting factors, including the energy-dependent factor for neutrons, the transmission of gamma rays through common shielding materials, and the effect of distance.
Who this is for
Students of radiation physics, radiography and nuclear medicine, radiation protection trainees and teachers.
Absorbed dose
D = E / m, in gray (1 Gy = 1 J/kg). 0.5 J deposited in a 70 kg body is about 7 mGy.
Equivalent dose
H = w_R × D, in sievert. ICRP 103 radiation weighting factors: - photons, electrons and muons: 1, - protons: 2, - alpha particles and heavy ions: 20, - neutrons: a continuous function of energy, peaking at about 20.7 near 1 MeV.
Effective dose
Effective dose sums equivalent doses to organs weighted by tissue factors w_T (for example 0.12 for lung and red marrow, 0.04 for thyroid). For uniform whole-body exposure, effective dose equals equivalent dose.
Shielding
A narrow gamma beam is attenuated exponentially: I = I₀ e^(−μx). At 662 keV (Cs-137), linear attenuation coefficients are about 1.25 cm⁻¹ for lead, 0.58 for steel, 0.20 for aluminium, 0.18 for concrete and 0.086 for water. The half-value layer (HVL) is ln 2 / μ, the tenth-value layer (TVL) ln 10 / μ. Broad beams include scattered photons (build-up), so real shields transmit more than this narrow-beam estimate.
Distance
For a point source the dose rate falls with the square of distance: tripling the distance cuts it to one ninth.
Typical doses
Natural background is about 2.4 mSv per year worldwide. A chest X-ray gives about 0.02 mSv, a CT scan of the abdomen around 8 to 10 mSv. The ICRP public dose limit is 1 mSv per year from practices, the occupational limit 20 mSv per year averaged over five years.
Good practice
Keep units consistent; dose rates in µSv/h are convenient for surveys. Use your institution's approved methods for real shielding design.
Time, distance and shielding are the three basic protection rules, applied together with the principle of keeping doses as low as reasonably achievable.
Worked example
0.5 J of gamma radiation in 70 kg gives 7.14 mGy and 7.14 mSv. Two centimetres of lead transmit 8.2 % of 662 keV gamma rays (HVL 0.55 cm). A dose rate of 100 µSv/h at 1 m falls to 11.1 µSv/h at 3 m, and to 0.91 µSv/h with the lead as well.
Limits
Narrow-beam attenuation without build-up; not an official shielding design or dose assessment.
Worked example
2 cm of lead transmits about 8 % of Cs-137 gamma rays.
Quick facts
- Category: Math & Science
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: ICRP Publication 103 (2007): absorbed dose D = E/m in gray, equivalent dose H = w_R·D with w_R = 1 for photons and electrons, 2 for protons, 20 for alpha particles and the continuous neutron function; narrow-beam attenuation I = I₀e^(−μx) with linear attenuation coefficients at 662 keV from NIST XCOM mass attenuation data; half- and tenth-value layers ln2/μ and ln10/μ; inverse-square law for a point source
Frequently asked questions
What is the difference between gray and sievert?
Gray measures absorbed energy; sievert weights it for radiation type.
What is the weighting factor for alpha particles?
20 under ICRP 103.
What is a half-value layer?
The thickness that halves a narrow gamma beam: ln2/μ.
How does distance reduce dose?
By the square of the distance for a point source.
What is the public dose limit?
1 mSv per year from practices (ICRP).
Is my data stored?
No. Everything is calculated in your browser.