Study and Productivity

Radiation Dose Units and Shielding: Gray, Sievert and Half-Value Layers

Understand absorbed, equivalent and effective dose, ICRP radiation weighting factors, how shielding attenuates gamma rays, HVL, and the inverse-square law.

Saizul Amin
Saizul Amin30 Oct 2026 · 3 min read
Radiation Dose Units and Shielding: Gray, Sievert and Half-Value Layers

Radiation Dose Units and Shielding: Gray, Sievert and Half-Value Layers

Radiation doses appear in news about medical scans, flights and nuclear incidents, often in confusing units. This guide explains what gray and sievert measure, how different radiation types are weighted, and how time, distance and shielding reduce exposure. You can calculate examples with the radiation dose and shielding calculator.

Absorbed dose: gray

Absorbed dose is the energy deposited per kilogram of matter:

D = E / m, in gray (Gy), where 1 Gy = 1 J/kg.

It is a physical quantity and applies to any material.

Equivalent dose: sievert

Different radiations cause different biological damage for the same energy. Alpha particles, which deposit their energy densely, are much more damaging than gamma rays. The equivalent dose weights absorbed dose:

H = w_R × D, in sievert (Sv).

ICRP Publication 103 sets the weighting factors:

Radiationw_R
Photons (X-rays, gamma)1
Electrons, muons1
Protons2
Alpha particles, heavy ions20
Neutrons2.5 to about 20.7, by energy

Effective dose

Organs differ in sensitivity. Effective dose sums equivalent doses to each organ multiplied by tissue weighting factors (for example 0.12 for lung, stomach, colon, breast and red bone marrow; 0.04 for thyroid). It is used to compare risks from different exposures. For uniform whole-body exposure, effective dose equals equivalent dose.

Putting numbers in context

ExposureTypical effective dose
Dental X-ray0.005 mSv
Chest X-ray0.02 mSv
Transatlantic flightabout 0.05 mSv
Natural background per yearabout 2.4 mSv (world average)
Abdominal CT scanabout 8–10 mSv
Occupational limit (ICRP)20 mSv per year averaged

Shielding gamma rays

A narrow beam of gamma rays is attenuated exponentially:

I = I₀ e^(−μx),

with μ the linear attenuation coefficient. For 662 keV gamma rays from caesium-137:

Materialμ (cm⁻¹)HVL
Lead1.250.55 cm
Steel0.581.2 cm
Aluminium0.203.4 cm
Concrete0.183.9 cm
Water0.0868.1 cm

The half-value layer (HVL) halves the intensity; the tenth-value layer (TVL) reduces it to 10 percent. In real broad-beam geometry, scattered photons add a build-up factor, so shields transmit more than the narrow-beam calculation suggests.

Distance

For a point source, dose rate falls with the square of distance. Moving from 1 m to 3 m reduces it to one ninth. Distance is often the cheapest protection.

Time

Dose is dose rate times time. Halving the time spent near a source halves the dose.

Using the calculator

  1. Enter the deposited energy and mass.
  2. Choose the radiation type and, for neutrons, the energy.
  3. Choose a shielding material or enter μ, and the thickness.
  4. Enter a dose rate and two distances.
  5. Read absorbed and equivalent dose, transmission, HVL, TVL and new dose rates.

Example

100 µSv/h at 1 m behind 2 cm of lead (8.2 percent transmission) and moved to 3 m becomes about 0.9 µSv/h.

Shielding other radiation

  • Alpha particles are stopped by a sheet of paper or the outer layer of skin; they are dangerous mainly when inhaled or swallowed.
  • Beta particles are stopped by a few millimetres of plastic or aluminium. Heavy metals are avoided because they produce secondary X-rays (bremsstrahlung).
  • Neutrons are slowed by hydrogen-rich materials such as water, polyethylene or concrete, and then absorbed by boron or cadmium.

Limits

The calculator uses narrow-beam attenuation without build-up and whole-body exposure. Real radiation protection decisions require qualified experts and approved methods.

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages