Proctor Compaction Test Calculator
Work out a standard or modified Proctor compaction test: pick the ASTM, BS or IS method or enter your own mould and rammer, record mould and soil masses with moisture tins, and get wet and dry densities, the compaction curve with maximum dry density and optimum moisture content, zero air voids and saturation lines, an oversize correction and field relative compaction results.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Pick the method
Choose ASTM, BS or IS standard or modified effort, or enter your own mould and rammer.
- 2Enter the points
For each compacted specimen type the mould mass, the mould with soil and the moisture or tin weighings.
- 3Set Gs
Enter the specific gravity for the zero air voids and saturation lines.
- 4Read MDD and OMC
Check the fitted curve, the peak and any warnings about bracketing or saturation.
- 5Correct and check
Apply the oversize correction if needed and enter field densities for relative compaction.
- 6Print
Print the report with the curve and tables, or export CSV and SVG.
About this tool
The Proctor test finds the moisture content at which a soil compacts to its highest dry density under a standard effort. Soil is mixed at several moisture contents, compacted in layers into a mould of known volume with a set number of rammer blows, weighed and sampled for moisture. Too dry and the particles resist being pushed together; too wet and the water takes up space that soil could fill. Between the two lies the optimum moisture content, and the dry density there is the maximum dry density that earthworks specifications refer to when they ask for 95 percent compaction. For each point the bulk density is the mass of compacted soil divided by the mould volume, and the dry density is the bulk density divided by one plus the moisture content. The tool fits a quadratic or cubic curve through the points and takes its peak inside the tested range as MDD and OMC, and warns when the peak is not bracketed by points on both the dry and wet side. The zero air voids line, ρd = Gs ρw / (1 + w Gs), shows the density the soil would reach if every pore were full of water; no test point should lie above it. Lines for 90 and 80 percent saturation are drawn too, and each point lists its degree of saturation and air voids. Presets cover ASTM D698 standard and D1557 modified effort in the 4 and 6 inch moulds, BS 1377-4 light and heavy compaction and IS 2720 Parts 7 and 8, and the compactive effort in kJ/m³ is computed from the mould, rammer, drop, layers and blows.
Oversize and field checks
When the sample contained oversize particles that were removed before the test, ASTM D4718 corrects the density and moisture for the whole material from the percent oversize, its bulk specific gravity and moisture. The field tab compares in-place dry densities from sand cone or nuclear gauge tests with the MDD, gives the relative compaction and the difference from optimum moisture, and marks each test pass or fail against your required percentage.
Units and output
Densities can be shown in g/cm³ (the same as Mg/m³), kN/m³ or lb/ft³. The curve, the point table and the field results print together on one report or export as CSV and SVG.
Limits
The fitted curve is a mathematical smoothing of your points and is not part of any standard; check that it follows the points. The tool does not cover vibrating hammer tests, the moisture condition value or one-point field methods. Verify with a qualified engineer.
Worked example
A road subgrade sample is tested by ASTM D698 in a 944 cm³ mould with a 4182 g mould mass. Five points at 8.4, 10.6, 12.8, 14.9 and 17.1 percent moisture give mould plus soil masses of 5924, 6058, 6146, 6158 and 6102 g, and dry densities of 1.702, 1.797, 1.844, 1.822 and 1.737 g/cm³. The cubic fit gives a maximum dry density of 1.843 g/cm³ at an optimum moisture content of 13.2 percent; the quadratic fit gives almost the same, 1.842 at 13.1. The compactive effort is 593 kJ/m³. With Gs = 2.68 the zero air voids density at optimum is 1.978 g/cm³, and the points range from 39 to 85 percent saturation. Two field tests at 1.79 and 1.71 g/cm³ give relative compaction of 97.1 percent (pass) and 92.8 percent (fail) against a 95 percent requirement.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: ASTM D698 and D1557 (laboratory compaction), ASTM D4718 (oversize correction), BS 1377-4:1990 clause 3, IS 2720 (Parts 7 and 8)
Frequently asked questions
What is the difference between standard and modified Proctor?
Modified Proctor (ASTM D1557, BS heavy, IS heavy) uses a heavier rammer, a higher drop and five layers, about 2700 kJ/m³ against 600 for standard. It gives a higher MDD at a lower OMC and is used for roads and airfields.
How is dry density calculated?
Divide the mass of compacted wet soil by the mould volume for bulk density, then divide by one plus the moisture content as a decimal. For example 2.0 g/cm³ at 12 percent moisture gives 1.786 g/cm³ dry.
Why do I need points on both sides of optimum?
The peak of the curve can only be found reliably if it is bracketed by at least two points drier and two wetter than optimum. The tool warns when the fitted peak falls outside the tested range.
What is the zero air voids line?
It is the dry density at full saturation for each moisture content and the specific gravity entered. Real compacted soil always has some air, so test points should plot below the line; a point above it means a weighing or Gs error.
What specific gravity should I use?
Use a measured value from a specific gravity test. Typical values are about 2.65 for quartz sands and 2.7 to 2.8 for clays; a wrong Gs moves the zero air voids line but does not change MDD or OMC.
What is relative compaction?
It is the field dry density divided by the laboratory maximum dry density, as a percentage. Specifications often require 95 percent of standard or modified MDD within a moisture window around optimum.
