Password Policy Generator

Set minimum and maximum length, composition, change and blocklist rules, paste and hint options, lockout and MFA, and get a policy plus a table showing where it meets NIST guidance.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Enter company details

    Owner and version.

  2. 2
    Set length rules

    Minimum and maximum.

  3. 3
    Choose other rules

    Changes, blocklist, paste.

  4. 4
    Set MFA

    And allowed factors.

  5. 5
    Check against NIST

    Eight-item table.

  6. 6
    Export and sign

    Policy and acknowledgement.

About this tool

Many password policies still demand a capital letter, a number, a symbol and a new password every 90 days. Research and current government guidance say these rules make security worse, because people respond with predictable patterns such as Summer2026! followed by Autumn2026!. This generator writes a modern password and authentication policy and compares each choice you make with NIST SP 800-63B, revision 4, the United States digital identity guidelines that many organisations around the world follow. You set the minimum length, the maximum length you accept, whether character-type rules apply, when passwords must be changed, whether new passwords are checked against a blocklist of common and breached passwords, whether pasting and password managers are allowed, whether hints or security questions are used and after how many failed attempts an account is locked or slowed down. A separate section sets multi-factor authentication: required for all accounts, required for remote and admin access, or not required, with a list of allowed second factors. The minimum length rule in the comparison depends on that choice, because the guidance accepts 8 characters when another factor is in use but expects 15 when the password stands alone. A responsibilities section lists what each person must do, such as never sharing codes and using separate admin accounts. The extra page prints a table of eight items with your policy, the NIST guidance and whether you meet it, and the checks list every gap. Two templates are included: a NIST-aligned policy with MFA and a strict legacy policy for comparison.

Who this is for

IT managers, security officers, managed service providers and small business owners who need a written password rule for staff, auditors or cyber insurance questionnaires.

Length beats complexity

A long passphrase of several unrelated words is easier to remember and much harder to guess than a short string full of symbols. That is why the guidance sets a length floor and asks verifiers to accept at least 64 characters, including spaces.

Why forced changes went away

When people must change passwords on a schedule they make small, guessable edits. The guidance recommends a change only when there is evidence of compromise, which the default policy follows.

Blocklists

Checking new passwords against lists of common, breached and context-specific words, such as the company name, stops the worst choices without any composition rule. Many identity platforms offer this as a setting.

Password managers and paste

Blocking paste pushes people toward short passwords they can type. Allowing paste and an approved password manager makes unique, long passwords practical for every system.

Lockout and throttling

Limiting failed attempts stops online guessing. The comparison accepts any limit from 1 to 100, and a short delay after each failure is often kinder to users than a hard lock.

Multi-factor authentication

A second factor protects accounts even when a password leaks. Authenticator apps and hardware security keys resist phishing better than SMS codes, which the default text allows only where nothing else works.

Limits

This policy compares your choices with a summary of NIST SP 800-63B revision 4; it is not legal advice or a certification. Check the current NIST text and any sector rules that apply to you before adopting it.

Worked example

The default NIST-aligned policy sets a 12-character minimum with MFA required for all accounts, accepts up to 64 characters, has no composition rules, asks for changes only after compromise, uses a blocklist, allows paste and password managers, uses no hints and locks after 10 failed attempts, so all 8 comparison items show Yes. The strict legacy template fails 4 items: composition rules, 90-day changes, blocked paste and hints.

Quick facts

Frequently asked questions

What does NIST say about password length?

At least 15 characters when the password is the only factor, or 8 when used with MFA, and accept at least 64.

Should passwords expire every 90 days?

The guidance says no. Change them when there is evidence of compromise.

Are symbol and number rules still needed?

NIST recommends not requiring mixtures of character types. Use length and a blocklist instead.

Which revision is used?

The comparison summarises NIST SP 800-63B revision 4. Check the current text before relying on it.

Can I keep stricter rules?

Yes. The policy text follows your choices, and the comparison table simply shows where they differ.

Is this legal or compliance advice?

No. It is a draft policy and a guidance comparison, not legal advice.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages