Electrical Load Schedule Maker
List each circuit's points, watts, demand share and cable run; the sheet sizes breakers and cables, checks voltage drop, balances phases and totals the board.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Enter the project
Add the project name, address, board name and supply type.
- 2Add circuits
List each circuit with type, points, watts, demand share, phase and run length.
- 3Check the settings
Adjust the breaker size factor, voltage drop limit and cable table if needed.
- 4Read the warnings
Fix circuits flagged for voltage drop, overload or phase imbalance.
- 5Review panel totals
Note maximum demand, the main breaker and incoming cable.
- 6Print or download
Print the two-page schedule or download it as a Word file.
About this tool
A load schedule is the table an electrician or engineer draws up before wiring a flat, house or shop. It lists every circuit on the distribution board with the number of points, the wattage, the expected demand, the breaker, the cable size and the phase it is connected to, and it ends with the panel totals that decide the main breaker, the incoming cable and whether a three-phase supply is needed. Utilities ask for it with a new connection or load extension, and building owners need it to check a contractor's quote. This maker builds that sheet in the browser. Enter each circuit with its type, points, watts per point, demand percentage, phase and cable run in metres. For each one it works out the design current from the load and a typical power factor for that kind of circuit, picks the next standard miniature circuit breaker above the design current times a size factor, chooses the smallest copper cable whose current rating covers the breaker, then checks voltage drop over the run and moves up a size if the drop is too high. Panel totals show the connected load, maximum demand in kW and kVA, the current on each phase, a suggested main breaker and incoming cable, and an imbalance warning for three-phase boards. The result prints as two A4 pages with notes and signature lines, or downloads as a Word file.
How sizes are chosen
Each circuit type has a power factor and a smallest breaker: 6 A for lighting and fans, 10 A for small sockets, 16 A for power sockets, air conditioners and geysers, 20 A for a cooker. The breaker is the next size from 6, 10, 16, 20, 25, 32, 40, 50 and 63 A at or above design current × 1.25. The cable table uses IEC 60364-5-52 method A1 ratings for copper PVC cable in conduit in an insulated wall, with voltage drop in millivolts per amp per metre; replace it with your national code's table or your cable maker's data for other methods.
Phases and demand
Demand percentage is the share of a circuit's connected load expected at the same time; sockets rarely all run together, so 50 to 60% is common. On a three-phase board, assign each circuit to R, Y or B, and the summary shows phase currents and warns when they differ by more than 20%.
Worked example
The sample two-bedroom flat has nine circuits totalling 9.6 kW connected and 7.7 kW of demand (8.4 kVA). The kitchen power circuit of three 1,000 W points draws 13.7 A, so it gets a 20 A breaker and 4 mm² cable, because 2.5 mm² is rated only 19.5 A in this method. Lighting circuits get 6 A breakers on 1.5 mm². The highest current is 36.7 A, which suggests a 50 A double-pole main breaker and 16 mm² incoming cable.
Limits
The sheet is a first estimate, not a design approval. It does not check cable grouping and temperature derating, fault levels, breaker curves or earthing, which a licensed electrician must confirm to BNBC, IS 732, BS 7671 or your local code.
Worked example
Kitchen power: 3 × 1,000 W ÷ (230 V × 0.95) = 13.7 A × 1.25 = 17.2 A → 20 A MCB, 4 mm² copper.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: IEC 60364-5-52 cable ratings and BS 7671 voltage drop values
Frequently asked questions
What is the difference between connected load and maximum demand?
Connected load adds up every point at full rating. Maximum demand applies the demand percentage of each circuit, because not everything runs at once, and it is what sizes the main breaker.
Why does a long circuit get a bigger cable?
Voltage drop grows with current and length. If the drop exceeds the limit you set, the tool moves to the next cable size until it is within the limit.
Which power factor is used?
Typical values per circuit type: 0.9 for lighting and sockets, 0.85 for fans and air conditioners, 0.8 for motors and 1.0 for heaters and cookers.
Does it choose RCCBs?
It marks socket, geyser and pump circuits for 30 mA residual current protection, which most codes require. Choose the RCCB rating and type with your electrician.
Can I use it for a three-phase house?
Yes. Pick the three-phase supply and assign circuits to R, Y and B. The summary shows each phase's current and the imbalance.
Can I change the cable table?
Yes. Edit the sizes, ratings and voltage drop values to match your national code or cable manufacturer.