Wheelchair Access Checker (Ramps, Doors, Turning Space)
Enter the height to climb and the ramp slope, plus door, corridor and turning widths, and see ramp length, landings, handrail needs and any shortfall.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Measure the rise
Height to climb.
- 2Choose the slope
1:12 or gentler.
- 3Read ramp length
Runs and landings.
- 4Measure doors and halls
Clear widths.
- 5Check results
And fix shortfalls.
About this tool
Step-free access lets wheelchair users, people with walking aids and parents with buggies get in and around a building. The US 2010 ADA Standards give clear numbers that are widely used as good practice: ramps no steeper than 1:12, no more than 30 inches (760 mm) of rise per run, level landings at least 60 inches (1,525 mm) long, doors with at least 32 inches (815 mm) of clear width, 36 inch (915 mm) wide routes, and a 60 inch (1,525 mm) turning circle. This checker turns those rules into ramp lengths and pass or fail checks for your measurements.
Who this is for
Homeowners adapting a house, small businesses, architects and builders, occupational therapists and accessibility auditors.
Ramp length
Ramp run = rise × slope ratio. At 1:12, a 450 mm rise needs 5.4 m of ramp. Gentler slopes, such as 1:15 or 1:20, are easier for many users but longer.
Runs and landings
Each run can rise at most 760 mm (30 in). Higher rises need intermediate level landings at least 1,525 mm (60 in) long. Landings are also needed at the top and bottom and where a ramp changes direction.
Handrails and edges
Ramps that rise more than 150 mm (6 in) need handrails on both sides, at 865 to 965 mm (34 to 38 in) high. Edge protection stops wheels slipping off.
Doors, corridors and turning
Doorways need at least 815 mm (32 in) clear width with the door open at 90 degrees. Accessible routes need at least 915 mm (36 in). A 1,525 mm (60 in) diameter circle, or a T-shaped space, lets a wheelchair user turn around.
A worked example
A 450 mm rise to a front door at 1:12 needs one 5.4 m run with level landings at each end and handrails on both sides. An 800 mm doorway is 15 mm short of the 815 mm minimum.
Other countries
Many countries have similar rules, such as the UK's Approved Document M and Australia's AS 1428.1, with slightly different figures. Check the rules that apply where you are.
## Surfaces and gradients Ramp surfaces should be firm, stable and slip-resistant in wet weather. Cross slopes should be minimal, at most 1:48 under ADA, so wheelchairs do not drift sideways. Avoid sudden changes in level; thresholds should be low and bevelled.
## Bathrooms Accessible toilets need space beside the toilet for transfer and grab bars about 840 to 915 mm high.
## Portable and temporary ramps Portable ramps help with one or two steps but should follow the same slope limits and be secured so they cannot slip.
## Lighting and signs Good lighting and clear signs help everyone find the accessible route.
Limits
A planning check using ADA figures, not a substitute for a professional access audit or local building approval. Not legal advice.
Worked example
A 450 mm rise at 1:12 needs a 5.4 m ramp with landings and handrails.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: 2010 ADA Standards for Accessible Design (US Department of Justice)
Frequently asked questions
What is the maximum ramp slope?
1:12 under the ADA standards.
How long a ramp for a 300 mm step?
About 3.6 m at 1:12.
How wide should a door be?
At least 815 mm (32 in) clear opening.
How much turning space is needed?
A 1,525 mm (60 in) circle.
When are handrails needed?
When a ramp rises more than 150 mm (6 in).
Is my data stored?
No. All of it stays in your browser.