Watts, Amps and Volts Converter
Pick DC, single-phase or three-phase, enter any two known values and get the rest with power factor, apparent and reactive power, plus a circuit load check.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Pick the system
In Converter choose DC, AC single phase or AC three phase.
- 2Choose what you know
Pick the pair you know: watts and volts, watts and amps, volts and amps, or volts and ohms.
- 3Enter values
Type the values and, for AC, the power factor from the nameplate or 1 for heaters.
- 4Use the table
Open Quick table to see amps for the same watts at common voltages and export it.
- 5List a circuit
In Circuit load check enter the voltage, breaker size and each appliance with watts and hours.
- 6Read the check
See total amps, the 125 % continuous figure, the smallest standard breaker and the energy cost.
About this tool
How many amps does a 2,000 watt heater draw? Will a kettle and a microwave trip the breaker if they run together? What current does a 10 kW three-phase motor take at 400 volts? These everyday electrical questions all come down to a few formulas, but the formulas change between direct current, single-phase alternating current and three-phase supplies, and power factor quietly changes the answer for motors and electronics. This converter handles all three systems. Enter any two of watts, amps, volts and ohms and it gives the others, with apparent power in volt-amperes and reactive power for AC. A quick table shows the current for one appliance at the voltages used around the world, and the circuit tab adds up everything plugged into one circuit to see whether the breaker can carry it.
The formulas
For DC, power P = V × I, current I = P ÷ V and resistance R = V ÷ I. For single-phase AC the real power in watts is V × I × PF, where PF is the power factor, and the apparent power is V × I in volt-amperes. For a balanced three-phase load with line-to-line voltage V, P = √3 × V × I × PF; if you know the line-to-neutral (phase) voltage instead, P = 3 × V × I × PF. The converter uses line-to-line voltage for three phase, as nameplates and supply specifications usually do. Reactive power, in var, is √(S² − P²).
Power factor
Heaters, kettles, toasters and incandescent bulbs are resistive, so their power factor is 1 and watts equal volt-amperes. Motors, compressors, transformers and some LED drivers and power supplies draw current that is out of step with the voltage, so they take more amps than their watts suggest. A 1,000 W motor with a power factor of 0.8 at 230 V draws 5.4 A, not 4.3 A. When a nameplate lists amps, use that figure directly.
Quick table
The table lists the current for the watts you enter at 12, 24 and 48 V DC and at the mains voltages used in different countries: 110-120 V in North America and parts of Latin America and Japan, 220-240 V in most of the world, and 400-480 V for three-phase supplies. It also exports as CSV.
Circuit load check
List the appliances on one circuit with their wattage, quantity and hours of use. The tool adds the wattage, converts it to amps at your voltage and compares it with the breaker or fuse. Loads that run for three hours or more are counted at 125 %, the continuous-load rule of the US National Electrical Code; other countries handle this differently, so treat it as a rule of thumb outside the US. The same list gives energy per day in kWh and the monthly cost at your electricity price.
Worked example
A 2,000 W heater on 230 V draws 8.7 A; on 120 V it draws 16.7 A, more than a 15 A circuit allows. A kitchen circuit at 230 V with a 2,200 W kettle, a 1,200 W microwave, a 150 W fridge and eight 10 W lights draws about 16.6 A with everything on at an average power factor of 0.95, slightly above a 16 A breaker, so the kettle and microwave should not run together.
Limits
This converter estimates current and load; it does not size cables, check voltage drop or design installations. Electrical work must follow your local wiring rules and is often legally restricted to qualified electricians. Real appliances can draw more at start-up than their running rating.
Worked example
2,000 W at 230 V = 8.7 A; at 120 V = 16.7 A. 10 kW three-phase at 400 V, PF 0.8 = 18.0 A.
Quick facts
- Category: Home & Life
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: IEC 60050 International Electrotechnical Vocabulary (active, apparent and reactive power) and NFPA 70 National Electrical Code 210.19-210.20
Frequently asked questions
How do I convert watts to amps?
For DC or a resistive AC load, divide watts by volts. For AC with a power factor, divide by volts × PF; for three phase, divide by √3 × line voltage × PF.
How many amps is 1,500 watts?
At 120 V it is 12.5 A, at 230 V about 6.5 A and at 240 V 6.25 A, for a resistive load such as a heater.
What is power factor?
The ratio of real power (watts) to apparent power (volt-amperes). It is 1 for heaters and lower for motors and some electronics, which draw extra current.
How do I calculate three-phase current?
I = P ÷ (√3 × V × PF), with V the line-to-line voltage. A 10 kW load at 400 V and PF 0.8 draws about 18 A per line.
Why does the circuit tab add 25 %?
The US National Electrical Code sizes circuits for continuous loads, those running three hours or more, at 125 % of their current. Tick Runs 3 h+ for such loads.
Can I convert volts and ohms to watts?
Yes. Choose Volts + ohms; the tool finds the current with Ohm's law and then the power.