Steam Table Calculator

Type pressure and temperature, or pressure with quality, enthalpy or entropy, and get the full state of water or steam from IAPWS-IF97: region, specific volume, density, enthalpy, internal energy, entropy, specific heats and speed of sound. Print saturation tables, see linear interpolation worked out next to the exact value and chain states for a cycle.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Pick the units

    Choose bar, MPa, kPa or psia and °C, K or °F at the top of the tool.

  2. 2
    Choose the known pair

    Select pressure and temperature, quality, enthalpy or entropy, depending on what your problem gives.

  3. 3
    Read the state

    Check the region, then read volume, enthalpy, entropy and the saturation values listed beside them.

  4. 4
    Make a table

    On the Saturation table tab set the range and step, then print or save the table as CSV.

  5. 5
    Practise interpolation

    Enter two table rows and a value between them to see each interpolation step and its error.

  6. 6
    Chain process states

    Add inlet and outlet states on the Process tab to get enthalpy changes and isentropic efficiency.

About this tool

Steam tables are the everyday reference for boiler operators, process engineers and thermodynamics students. Printed tables give values only at round numbers, so every real problem ends with interpolation, and superheated tables jump in big pressure steps. This calculator works out the properties directly from the industrial formulation that the International Association for the Properties of Water and Steam published in 1997, known as IAPWS-IF97, which is the same basis used by the steam tables in most engineering textbooks and plant software. It covers compressed water (region 1), superheated steam (region 2), the near-critical region (region 3), the saturation line (region 4) and the boundary between regions 2 and 3, from 0 °C to 800 °C and up to 1000 bar. You can enter any common pair of known values: pressure and temperature, pressure and quality, temperature and quality, pressure and enthalpy, or pressure and entropy. The last two are what you need for throttling and turbine problems. Pressure units are bar, MPa, kPa or psia, and temperatures can be °C, K or °F.

What you get

For each state the tool shows the region, specific volume and density, specific enthalpy and internal energy, specific entropy, cp, cv and the speed of sound in single-phase states, or the dryness fraction in the wet region. For any pressure below the critical point it also lists the saturated liquid and vapour values and says how many degrees the state is subcooled or superheated. The Saturation table tab prints a table by temperature or by pressure with vf, vg, hf, hfg, hg, sf and sg, which you can save as CSV for a spreadsheet.

Interpolation steps

The Interpolation tab is for exam practice. Enter two table temperatures and the temperature you need, and the tool performs the textbook straight-line interpolation for pressure, vg, hf, hfg, hg and sg, then shows the exact IF97 value beside it and the error. You will see that enthalpy interpolates almost perfectly, while pressure and specific volume, which curve strongly, can be off by a percent or more.

Process states

On the Process tab you can list states such as turbine inlet, turbine exhaust and condensate, see the change in enthalpy and entropy between them, and get the isentropic efficiency of the expansion from the first two states.

Accuracy and limits

The formulation was checked against every computer-program verification value in the IAPWS release, from compressed water at 80 MPa to near-critical states. It does not include region 5 (above 800 °C), metastable states, viscosity or thermal conductivity. Results are for pure water, not for boiler water with additives, and they are not a substitute for the design codes that govern pressure equipment.

Worked example

A student needs the properties of steam at 40 bar and 400 °C entering a turbine and leaving at 0.1 bar with 92 % quality. The calculator gives region 2 with h = 3214.4 kJ/kg and s = 6.7712 kJ/(kg·K) at the inlet. At 0.1 bar the saturation temperature is 45.81 °C, and with x = 0.92 the exhaust enthalpy is 2392.5 kJ/kg. The work per kilogram is about 821.9 kJ. The isentropic end state at 0.1 bar with the inlet entropy has h2s = 2144.5 kJ/kg, so the turbine efficiency is about 76.8 percent.

Quick facts

Frequently asked questions

Which steam table standard does this use?

The IAPWS Industrial Formulation 1997 (IAPWS-IF97) in its 2012 revision, regions 1 to 4 and the region 2 to 3 boundary. It is the internationally agreed basis for industrial steam calculations.

How do I find the state of wet steam?

Choose pressure and quality or temperature and quality, then type the dryness fraction from 0 for saturated liquid to 1 for dry saturated steam. Enthalpy, entropy and volume are mixed in proportion to the quality.

Can it do throttling calculations?

Yes. Throttling keeps enthalpy constant, so find h at the inlet, then use pressure and enthalpy at the outlet pressure. The tool tells you whether the result is wet or superheated and gives the quality or the temperature.

Why does my textbook value differ slightly?

Older tables were based on the 1967 formulation or were rounded. IF97 values can differ in the last digit or two, and interpolated table values differ more where properties curve.

Does it include the critical region?

Yes, region 3 near the critical point at 373.946 °C and 220.64 bar is solved from its own density-based equation. Very close to the critical point small changes in input give large changes in volume, so expect sensitivity there.

Can I use psia and °F?

Yes. Pick psia and °F at the top. Enthalpy and entropy stay in kJ/kg and kJ/(kg·K); divide enthalpy by 2.326 for Btu/lb if you need it.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser