Sound Level Meter with Noise Log

Start the mic, calibrate against a known level if you can, then log noise second by second with charts, events above a threshold, notes and exports.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Start the microphone

    Press Start microphone and allow access; choose another microphone if you have one.

  2. 2
    Choose weighting

    Pick A, C or Z frequency weighting and Fast or Slow time weighting.

  3. 3
    Calibrate

    Enter what a trusted meter or calibrator reads and press Calibrate to this now, or type an offset.

  4. 4
    Log

    Press Start logging, set an event threshold and add notes when you hear something specific.

  5. 5
    Review

    Stop and save the log, then read Leq, Lmax, L10, L90, the chart and the event table.

  6. 6
    Export

    Download the per-second CSV or the printable HTML report; open older logs from Saved logs.

About this tool

Noise complaints, home studio checks, classroom noise, a new fridge that seems loud, or a party next door that goes on every weekend: a sound level meter puts a number on it, and a log shows when and how long it happens. Most meter apps show a needle and little else. This page measures with your device microphone and applies the A, C or Z frequency weighting defined in IEC 61672-1, the same curves used by professional meters, together with Fast (125 ms) or Slow (1 s) time weighting. It shows the live level, the equivalent continuous level Leq, the maximum and minimum, and L10 and L90, which describe the loud moments and the background. Long logging stores one row per second in your browser, autosaves every 15 seconds, keeps the screen awake where possible, and finds events where the level stayed above your threshold. Notes typed while logging are stamped with the time.

Not a calibrated instrument

A real class 1 or class 2 meter has a measurement microphone with a known sensitivity and flat response, and it is checked with an acoustic calibrator. Phone and laptop microphones are not: their sensitivity varies by device, they often roll off below 100 Hz and above 10 kHz, some apply processing the browser cannot switch off, and loud sounds above about 100 dB may clip. This tool requests raw audio with echo cancellation, noise suppression and automatic gain turned off, but it cannot guarantee the hardware obeys. Treat the readings as estimates for your own records. For legal disputes, workplace exposure or planning conditions, a council officer or acoustic consultant has to measure with certified equipment.

Calibration offset

Digital audio is measured relative to full scale (dBFS). The offset converts that to an estimated sound pressure level. The best method is to hold the device next to a trusted meter, type the meter's reading in Reference reads and press Calibrate to this now; a 94 dB acoustic calibrator over the microphone works too. Without calibration the default offset is only a rough guess.

Reading the log

The chart shows the 1-second Leq in blue and the maximum in each second in pink, with the event threshold as a dashed line. Events merge loud seconds that are less than five seconds apart and ignore bursts shorter than three seconds. The CSV export has ISO time stamps, Leq, Lmax and Lmin per second and the offset used; the HTML report summarises the log with the event table and your notes, ready to print.

Worked example

A tenant calibrates a phone against a borrowed meter at 62.0 dB in a quiet living room; the tool sets the offset to 101.4 dB. She logs from 22:30 to 01:30 with A weighting, Fast, and an event threshold of 45 dB. The report shows LAeq 41.8 dB over three hours, L90 33.2 dB background, LAmax 68.4 dB, and 14 events, the longest from 23:52 to 00:41 with an Leq of 52.6 dB, matching her note music through the wall. She keeps the CSV and the printed report as her diary.

Quick facts

Frequently asked questions

What is the difference between dBA and dBC?

A weighting follows how the ear hears quiet sounds, so it counts bass much less; it is used for most noise limits. C weighting is nearly flat down to about 30 Hz and shows bass-heavy noise such as music through walls or engines.

What do Leq, L10 and L90 mean?

Leq is the steady level with the same energy as the varying noise over the period. L10 is the level exceeded 10 % of the time (the loud moments) and L90 the level exceeded 90 % of the time (the background).

Can I use the log as evidence?

It can support a diary of when noise happened, but it is not a certified measurement. Authorities usually measure themselves with calibrated meters; ask your local council or landlord what they accept.

Why does my phone read differently from my friend's?

Microphone sensitivity and processing differ between models. Calibrate each device against the same reference before comparing results.

Does logging keep working with the screen off?

Browsers may pause the microphone when the screen locks or the tab is in the background. Keep the tab open and the device on charge; the page asks the browser to keep the screen awake.

Where are logs stored?

In this browser's storage on your device. They are not uploaded; export the CSV or report to keep a copy elsewhere.