Snow Load Calculator

Enter the ground snow load for your site, choose exposure, thermal and importance factors and the roof slope, and get the design roof snow load, drift surcharge and a printable load sheet.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Choose the method

    Pick ASCE 7-16 for psf or Eurocode for kN/m², and enter the roof slope.

  2. 2
    Enter the ground load

    Type pg or sk from your local authority.

  3. 3
    Set the factors

    Choose exposure, thermal and importance factors and say if the roof is slippery.

  4. 4
    Read the roof load

    See pf, Cs, the minimum load and the design load, with a chart by slope.

  5. 5
    Check drifts

    In Drift, enter the upper roof length and the height difference.

  6. 6
    Make a load sheet

    In Load sheet, enter dead load, span and spacing, then print the sheet.

About this tool

Sheds, carports, garden rooms, greenhouses and lean-to roofs often go up without an engineer, and every winter some of them collapse under snow. The first step in avoiding that is knowing how much snow the roof must carry. This calculator turns the ground snow load for your site, which you get from your building department or the national snow map, into a roof snow load using the method of ASCE 7-16 in the United States or EN 1991-1-3 in Europe. For ASCE 7 you choose the exposure factor (how windswept the roof is), the thermal factor (heated or unheated building), the importance factor and whether the roof is slippery. The tool applies the flat roof formula, the slope factor that lets snow slide off steep or slippery roofs and the minimum load for low-slope roofs. A drift tab estimates the extra snow that piles against a higher wall, and a load sheet converts everything into a load per rafter you can hand to a builder.

The ASCE 7 method

ASCE 7-16 starts from the ground snow load pg in pounds per square foot. The flat roof load is pf = 0.7 × Ce × Ct × Is × pg. The factor 0.7 reflects the fact that roofs usually hold less snow than the ground. Ce, the exposure factor, is lower for windswept roofs and higher for sheltered ones; Ct, the thermal factor, is 1.0 for heated buildings and 1.2 for unheated ones such as sheds, because snow does not melt from below; and Is, the importance factor, is 0.8 for low-risk structures and up to 1.2 for essential facilities.

Slope and slippery roofs

Snow slides off steep roofs. The slope factor Cs stays at 1 up to a slope that depends on the thermal factor and roof surface, then falls in a straight line to zero at 70°. A slippery, unobstructed metal or glass roof sheds snow at lower slopes. For roofs under 15° a minimum load applies: Is × pg when pg is 20 psf or less, and 20 × Is above that.

Drifts

Wind blows snow off a higher roof and dumps it against the wall of a lower one. ASCE 7 estimates the drift height as 0.43 × (upper roof length)^(1/3) × (pg + 10)^(1/4) − 1.5 feet and the snow density as 0.13 pg + 14 pounds per cubic foot. The drift adds a triangular surcharge up to four times its height wide. Lean-to sheds against houses are exactly this case.

Eurocode

EN 1991-1-3 uses s = μ1 × Ce × Ct × sk in kN/m², with μ1 = 0.8 up to 30°, falling to zero at 60°. Choose it if your country uses the Eurocodes and take sk from the national annex.

Worked example

An unheated shed (Ct 1.2, Is 0.8) in a partially exposed garden (Ce 1.0) where pg is 30 psf, with an 18° roof, has pf = 0.7 × 1.0 × 1.2 × 0.8 × 30 = 20.16 psf. The slope is below the 45° limit for cold roofs, so Cs = 1 and the design load is 20.2 psf, about 0.97 kN/m². If the shed is against a house whose roof is 30 ft deep and 4 ft higher, a drift of 1.86 ft adds up to 33.3 psf over 7.4 ft.

Limits

This is an educational estimate, not a structural design or professional advice. Ground snow loads, factors and code editions are set by your local building authority, and newer editions such as ASCE 7-22 change some factors. Unbalanced, sliding and rain-on-snow loads are not covered. Have a qualified engineer check any structure people use or where failure would cause harm.

Worked example

Unheated shed, pg 30 psf, Ce 1.0, Ct 1.2, Is 0.8, 18° roof: 0.7 × 1.0 × 1.2 × 0.8 × 30 = 20.2 psf design snow load.

Quick facts

Frequently asked questions

Where do I find the ground snow load?

From your local building department or the snow load map in your national code. In the US, ASCE 7 publishes maps and many counties set their own values.

Why is a shed's thermal factor higher?

Heat escaping through a heated roof melts snow from below. An unheated shed has no such melting, so ASCE 7 uses Ct = 1.2.

Does a steep roof carry no snow?

Snow slides off as the slope increases. Cs falls to zero at 70°, and slippery roofs shed snow at lower slopes.

What is a drift?

A pile of wind-blown snow against a higher wall or roof step. It adds a large triangular load to the lower roof next to the wall.

Can I use metric units?

Choose the Eurocode method to work in kN/m², or use ASCE 7 and read the kN/m² conversion shown with every result.

Is this enough to build a carport?

It tells you the snow load to design for. The rafters, posts and connections still need to be sized for it by a span table or an engineer.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages