Rain Gutter Capacity Calculator

Enter each roof slope with length, plan depth and pitch, pick a gutter profile and rainfall intensity, and see the flow, gutter capacity, outlets and downpipes needed and when it would overflow.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Add roof slopes

    In Roof, add each slope with gutter length, plan depth and pitch.

  2. 2
    Pick a gutter

    In Gutter and rain, choose a half-round size, a box gutter or a custom area.

  3. 3
    Set outlets

    Tick whether outlets are in the middle of runs and set a long-gutter reduction if needed.

  4. 4
    Set rainfall

    Enter the design intensity and a heavy storm intensity to test.

  5. 5
    Read the result

    Sizing result shows effective area, flow, outlets per run and the overflow intensity.

  6. 6
    Export

    Export the sizing table to CSV for your builder or roofer.

About this tool

Overflowing gutters soak walls, rot fascias and send water into foundations, and the cause is often simple: too small a gutter or too few downpipes for the roof. This calculator sizes eaves gutters with the method of the European standard BS EN 12056-3. For each roof slope you enter the length of gutter, the horizontal depth from gutter to ridge and the pitch. The tool works out the effective catchment area, which for pitched roofs adds half the height of the slope to allow for wind-driven rain, and the design flow in litres per second at the rainfall intensity you choose. It calculates the capacity of half-round, box or custom gutters from their cross-section, decides how many outlets and downpipes each run needs with end or centre outlets, and shows the rainfall intensity at which the system would overflow, checked against a heavy storm figure you enter.

Effective roof area

Rain does not fall vertically in a storm, so a pitched roof catches more than its plan area. BS EN 12056-3 uses an effective area of plan length × (plan width + half the rise). A slope 10 m long and 4.5 m deep at 35° rises 3.15 m, so its effective area is 10 × (4.5 + 1.58) = 60.8 m², a third more than the plan area.

Flow and rainfall intensity

The design flow in litres per second is the effective area times the rainfall intensity in millimetres per hour, divided by 3,600. A common UK design intensity is 75 mm/h (0.021 litres per second per m²); short tropical or summer storms can reach 150-200 mm/h. Local building codes and rainfall maps give the right figure for your site and the level of risk you accept.

Gutter capacity

For a level eaves gutter that discharges freely at an outlet, the standard gives a nominal capacity of 2.78 × 10⁻⁵ × A^1.25 litres per second, where A is the cross-sectional area of the gutter in square millimetres. A 112 mm half-round gutter has about 4,926 mm² and carries about 1.15 L/s to one end outlet. An outlet in the middle of a run lets water flow from both sides, roughly doubling what the run can carry. Very long runs carry less, which the reduction factor allows for.

Worked example

Each 10 m slope above has an effective area of 60.8 m² and, at 75 mm/h, a flow of 1.27 L/s. A 112 mm half-round gutter with an end outlet carries 1.15 L/s, so each run needs two outlets, four downpipes for the house. With central outlets each run needs only one. One outlet per run would overflow above about 68 mm/h.

Limits

This is a design aid, not a certified drainage design or professional advice. The capacity formula assumes level, free-discharging gutters without sharp bends; falls, angles, outlet size, debris and snow change real performance. Use manufacturer capacity tables for your exact system, and follow BS EN 12056-3 or your local plumbing code and a qualified designer for buildings where failure matters.

Worked example

Slope 10 m × 4.5 m at 35°: effective area 60.8 m², flow 1.27 L/s at 75 mm/h; a 112 mm half-round gutter (1.15 L/s) needs two end outlets.

Quick facts

Frequently asked questions

How do I measure plan depth?

Measure horizontally from the gutter line to the ridge or the top of the slope, for example on a plan drawing, not along the sloping roof.

Why does pitch increase the area?

Wind drives rain onto the sloping face, so a pitched roof collects more than its footprint. BS EN 12056-3 adds half the vertical rise to the plan depth.

What rainfall intensity should I use?

Use the design value from your building code or national rainfall maps. 75 mm/h is common in the UK; tropical regions need much higher values.

How many downpipes do I need?

One for each outlet. The tool counts outlets for each run from the flow and the gutter capacity.

Do central outlets help?

Yes. With an outlet in the middle, water flows to it from both directions, so one outlet can drain roughly twice the length.

Can I size a box gutter?

Choose Box and enter its width and depth, or enter a known cross-section area. The same capacity formula is applied.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages