Pile Capacity Calculator

Enter pile diameter and length with soil strength or friction parameters to get shaft and base resistance, ultimate and allowable capacity, or the efficiency of a pile group.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Choose the soil

    Clay, sand or group.

  2. 2
    Enter pile size

    Diameter and embedded length.

  3. 3
    Add soil parameters

    cu, γ′, β and Nq.

  4. 4
    Set the safety factor

    For the allowable load.

  5. 5
    Read capacities

    Shaft, base and total.

About this tool

A pile carries load by friction along its shaft and by bearing at its base. In clay, shaft friction is usually estimated with the alpha (total stress) method: fs = α·cu, where the adhesion factor α falls as the clay gets stronger relative to the overburden pressure. The base resistance in clay is about 9·cu. In sand, the beta (effective stress) method gives fs = β·σ′v along the shaft and q = Nq·σ′v at the base, often with limiting values. This calculator applies both methods for a pile in a single layer, gives the ultimate capacity and the allowable load with your factor of safety, and a group mode estimates the efficiency of a rectangular pile group with the Converse-Labarre formula.

Who this is for

Geotechnical and structural engineers, piling contractors, students and engineers making preliminary designs.

Clay: alpha method

- Mean vertical effective stress at mid-length: σ′v = γ′·L/2. - API RP 2GEO: ψ = cu/σ′v; α = 0.5·ψ^−0.5 for ψ ≤ 1, 0.5·ψ^−0.25 for ψ > 1, at most 1. - Shaft resistance Qs = α·cu·π·D·L. - Base resistance Qb = 9·cu·π·D²/4.

Sand: beta method

- Shaft friction fs = β·σ′v, with β typically 0.25-0.4 for bored piles and 0.3-0.8 for driven displacement piles. - Base resistance q = Nq·σ′v at the toe, with Nq from 20 to 60 depending on the friction angle and installation, often limited to 5-12 MPa. Values depend strongly on installation method; use local correlations or load tests.

Factor of safety

Working stress design often uses a global factor of 2 to 3 on the ultimate capacity. Eurocode 7 instead applies partial factors and model factors and rewards load testing.

Group efficiency

Piles close together interact. The Converse-Labarre formula gives η = 1 − θ·[(n − 1)m + (m − 1)n]/(90·m·n), with θ = atan(D/s) in degrees. A 3 × 3 group of 0.6 m piles at 1.8 m spacing has η = 73 %. Groups in sand driven at normal spacing often show efficiencies near or above 1; in clay, block failure must also be checked.

Worked example

A 0.6 m bored pile, 15 m long in clay with cu = 50 kPa and γ′ = 8 kN/m³: σ′v = 60 kPa, α = 0.55, Qs = 774 kN, Qb = 127 kN, ultimate 902 kN and allowable 361 kN with FS = 2.5.

Example uses

A designer compares a 0.6 m and a 0.75 m pile for a bridge pier.

Limits

Single homogeneous layer, axial compression only; negative skin friction, settlement, tension and lateral loads are not checked. This is not professional engineering advice.

Worked example

0.6 m pile, 15 m in clay with cu 50 kPa: ultimate 902 kN, allowable 361 kN at FS 2.5.

Quick facts

Frequently asked questions

What is the alpha method?

A total stress method where shaft friction equals α times the undrained shear strength.

What is the beta method?

An effective stress method where shaft friction equals β times the vertical effective stress.

Why is end bearing in clay 9·cu?

It is the bearing capacity factor Nc for deep foundations.

What factor of safety is used?

Often 2 to 3 on the ultimate capacity.

Do pile groups carry less than single piles?

In clay often yes; in sand the efficiency can be close to 1.

Is my data stored?

No. Clearing the page clears everything.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages