PAT Testing and Portable Appliance Inspection Register

Record each appliance's inspections and test readings, check them against limits, get the next due date for its environment and print labels and registers.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Set up the site

    Enter the organisation, main environment and the limits your instrument and procedure use.

  2. 2
    Add each appliance

    Record the ID, description, location, category and class the first time you inspect it.

  3. 3
    Enter the results

    Choose the inspection type, record the visual result and any earth, insulation and leakage readings.

  4. 4
    Check the status

    See pass or fail with the reason and the next due date for each appliance.

  5. 5
    Deal with failures

    Withdraw failed items, record repairs as a new entry and watch the overdue list.

  6. 6
    Print labels and registers

    Print pass and do-not-use labels, the register by location and the overdue list.

About this tool

The Electricity at Work Regulations 1989 require employers to keep electrical equipment safe, and for portable appliances that means a mix of user checks, formal visual inspections and, for some items, combined inspection and testing, often called PAT testing. The law does not set a fixed interval. HSE guidance and the IET Code of Practice suggest starting points that depend on the environment and the kind of appliance: a kettle in an office can go two years between tests, while a drill on a building site needs testing every few months. Whatever interval you choose, you need a register that shows each appliance, when it was last inspected, what was found and when it is next due. This register gives every appliance an ID and records each inspection against it, so the history builds up over the years. Choose a category such as hand-held, portable or IT and a class such as I (earthed), II (double insulated) or III (battery or SELV), and the tool suggests the next formal visual inspection or test date. Readings for earth continuity, insulation resistance and leakage are checked against limits you can change, failed items are flagged until they are repaired or withdrawn, and pass or do-not-use labels print in a few clicks.

Intervals by environment

The suggested intervals come from a table of six environments, from offices and shops through hotels, schools, equipment used by the public and commercial kitchens to 110 V construction sites. Each gives a formal visual interval and a combined test interval for class I and class II equipment. Hand-held items get half the interval, stationary and IT equipment double, and class III or battery items need visual inspection only. These are example starting points: lengthen them if years of results show few faults, or shorten them for equipment that is moved and abused. You can type your own interval on any entry.

Test limits

For class I appliances the tool checks earth continuity against 0.1 Ω plus an allowance for the lead, which you can enter for longer flexes. Insulation resistance at 500 V DC should be at least 1 MΩ for class I and 2 MΩ for class II, protective conductor current no more than 3.5 mA for class I and touch current no more than 0.25 mA for class II. Extension leads also get a polarity check. Any failure marks the appliance “do not use” until a later entry shows a repair and pass, or it is withdrawn or disposed of.

Worked example

The sample office has ten inspection entries for eight appliances in five locations. The kettle passed in October 2024 and again on 14 October 2026, so the older entry is marked superseded and the next test is October 2028. The microwave reads 0.12 Ω, within its 0.13 Ω limit once the lead's 0.03 Ω is added, and as stationary equipment is next due in October 2030. The four-way extension lead reads 0.22 Ω against a limit of 0.15 Ω and the fan heater has insulation resistance of only 0.6 MΩ, so both are flagged as failed and in use. The hairdryer with a cracked case has been withdrawn. A laptop charger last inspected on 3 June 2022 had a 48-month interval and became overdue on 3 June 2026. The summary shows five appliances in date, one overdue, two failed and one withdrawn.

Limits

The register is a record-keeping aid, not legal advice and not a substitute for a competent person. It does not take readings, does not know the instructions for your test instrument and cannot tell whether an interval suits your premises. Fixed wiring is covered by electrical installation condition reports, not by this register.

Worked example

8 appliances: 5 in date, 1 overdue charger, a failed extension lead (0.22 Ω vs 0.15 Ω) and fan heater (0.6 MΩ), and 1 hairdryer withdrawn.

Quick facts

Frequently asked questions

Is PAT testing a legal requirement?

The law requires electrical equipment to be maintained so it is safe, but it does not require PAT testing at fixed intervals. Inspection and testing is a common way to show you have done that, and many insurers and landlords expect records.

What is the difference between a visual inspection and a test?

A formal visual inspection checks the plug, fuse, cable, cable grip and case without instruments, and finds most faults. A combined inspection and test adds instrument readings such as earth continuity and insulation resistance.

How often should I test?

It depends on the equipment and how it is used. The tool suggests example starting intervals by environment, category and class, based on the IET Code of Practice and HSE guidance. Review them against your own results.

Do class II appliances need testing?

They need regular visual inspection, and an insulation or touch current test at longer intervals. They have no earth, so there is no earth continuity test. Class III and battery equipment generally need only a visual check of the charger.

Who can do the tests?

A competent person: someone with the right knowledge, training and equipment. Many small businesses train a member of staff to do visual inspections and use a contractor for testing.

What should a label show?

The appliance ID, the date of the inspection or test, the next due date and who did it. Failed items should be labelled clearly as not to be used and taken out of service.