Occupancy Load Calculator

List each space with its use and area, see the occupant load from IBC load factors, check the number and width of exits, and print a maximum occupancy sign.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Set the unit

    Choose square feet or square metres and name the venue.

  2. 2
    Add spaces

    Press + Space for each room or zone and pick its use.

  3. 3
    Enter areas

    Type the net or gross area as the use requires; edit the load factor if your code differs.

  4. 4
    Check exits

    In Exits, enter the number of exits and total clear door and stair widths.

  5. 5
    Read the result

    See the occupant load, exits required and how many people your exits can serve.

  6. 6
    Print the sign

    In Sign, print a large maximum occupancy sign.

About this tool

How many people can safely be in a room? Event organisers, restaurant owners, church and community hall managers, schools and landlords all need the answer, and fire officials check it. Building codes work it out from floor area and use: a crowded standing area allows one person per 5 square feet, an office one per 150. This calculator applies the occupant load factors of the International Building Code, which many jurisdictions adopt, and lets you edit them for local codes. You add each space with its use and its net or gross area, in square feet or square metres. The tool rounds each space up to whole people, totals them, says how many exits the load requires and checks your door and stair widths against the code's inches per occupant. It also prints a large Maximum Occupancy sign showing the lower of the calculated load and what your exits can serve.

Load factors

Table 1004.5 of the IBC gives the floor area allowed per occupant for each use. Assembly areas with chairs only are 7 net square feet per person, standing space 5, and tables and chairs 15. Classrooms are 20 net, business areas 150 gross, retail sales floors 60 gross, commercial kitchens 200 gross, warehouses 500 gross. Net area excludes walls, columns, corridors, toilets and fixed fittings; gross area is measured to the outside of the walls.

From people to exits

The total occupant load sets the minimum number of exits per storey: two for up to 500 people, three for 501 to 1,000 and four above. It also sets the egress width: 0.3 inches per occupant on stairs and 0.2 inches for doors and other components, reduced to 0.2 and 0.15 inches in buildings with sprinklers and an emergency voice alarm system. If your exits are narrower than required, the permitted occupancy must be lower.

Mixed spaces

Most buildings have several uses. A hall with a dance floor, a stage and a kitchen is worked out space by space and added up. The tool keeps each space separate so you can see which one drives the total.

Worked example

A community hall has a 2,400 sq ft main hall with tables and chairs (15 sq ft each), 300 sq ft of standing space by the stage (5 sq ft each) and a 400 sq ft kitchen (200 sq ft each). That is 160 + 60 + 2 = 222 people. Two exits are required. Without sprinklers, the doors need 222 × 0.2 = 44.4 inches of clear width in total; two 36-inch doors (72 inches) are enough for 360 people, so the sign shows 222.

Limits

This is a planning estimate, not an official occupancy certificate or professional advice. Your local fire marshal or building official sets the legal maximum, applies the code edition adopted where you are and may consider fixed seating, travel distance, exit separation and other factors. Post only the occupancy approved by them.

Worked example

Hall 2,400 sq ft at 15 + stage 300 at 5 + kitchen 400 at 200 = 160 + 60 + 2 = 222 people, two exits, 44.4 in of door width.

Quick facts

Frequently asked questions

How is occupancy load calculated?

Divide the floor area of each space by the load factor for its use from the building code, round up and add the spaces together.

What is the difference between net and gross area?

Net area is the usable floor, excluding walls, corridors, toilets and fixed equipment. Gross area is measured to the outside of the walls. The code says which to use for each use.

How many exits do I need?

Under the IBC, two exits for up to 500 occupants per storey, three for 501 to 1,000 and four for more than 1,000.

How wide must the exit doors be?

At least 0.2 inches per occupant in total (0.15 in sprinklered buildings with voice alarm), plus minimum door sizes set elsewhere in the code.

Can I use square metres?

Yes. Choose square metres; the tool converts to square feet to apply the IBC factors.

Is the printed sign official?

No. It is a draft. Post the occupancy approved by your fire or building official, often on their own sign.