India Electricity Connected Load Calculator

List your appliances to work out the connected load and expected maximum demand, compare it with the sanctioned load on your bill, and see the suggested load, connection type, extension fee and fixed charges.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    List appliances

    Watts and quantity.

  2. 2
    Add hours

    For monthly kWh.

  3. 3
    Set diversity

    Share used together.

  4. 4
    Enter sanctioned load

    From your bill.

  5. 5
    Read the result

    Load and phase.

  6. 6
    Compare charges

    Now and suggested.

About this tool

Every electricity connection in India has a sanctioned load, the number of kilowatts your distribution company (discom) has agreed to supply, printed on your bill. It decides your fixed charges each month, the size of your meter and service cable, and whether you get a single-phase or three-phase connection. As homes add air conditioners, geysers, induction cooktops, water pumps and now electric vehicle chargers, many families end up using far more than their sanctioned load. With smart meters recording the maximum demand every 15 or 30 minutes, discoms increasingly bill a penalty or raise the sanctioned load automatically when it is exceeded. Others ask for more load than they need and pay higher fixed charges every month for nothing. Two numbers are often confused. Connected load is the total rated power of everything wired into the house, as if it all ran at once. Maximum demand is what is actually drawn at the busiest moment, which is lower because not everything runs together; the ratio between them is called the diversity factor. Discoms usually look at both. This calculator adds up your appliances, with their wattage, quantity and hours of use, to give the connected load and monthly energy. It applies a diversity factor to estimate the maximum demand in kW and kVA, suggests a sanctioned load rounded up to the next kilowatt, tells you whether a single-phase connection is enough under your discom's limit and works out the load extension needed with its fee. It also compares the fixed charges at your current and suggested load, so you can decide whether to apply for an increase or a reduction.

Who this is for

Households adding an AC or EV charger, people who received a load penalty, landlords and builders planning connections, and electricians explaining a load survey to a customer.

Typical appliance ratings

| Appliance | Watts | |---|---| | LED bulb | 9-12 | | Ceiling fan | 50-75 | | 1.5 ton split AC | 1,500-1,800 | | Geyser | 2,000-3,000 | | Induction cooktop | 1,500-2,000 | | Home EV charger | 3,300-7,400 |

Diversity factor

Homes rarely use more than 50% to 70% of their connected load at once. Raise the factor if you often run ACs, geysers and the EV charger together.

Single-phase or three-phase

Many discoms allow single-phase supply up to 5 to 8 kW and require three-phase above that. A three-phase connection also balances heavy loads such as several ACs.

Applying for a change

Under the Electricity (Rights of Consumers) Rules, 2020, load changes can be applied for online with set timelines. The discom may inspect the wiring and charge a fee per kW.

Limits

Ratings, diversity and tariffs here are estimates; your discom's tariff order and supply code decide the rules. This is not an electrician's load survey or official advice.

Worked example

A home with two 1.5 ton ACs, two geysers, an induction cooktop, a pump and a 3.3 kW EV charger: 15.8 kW connected, about 9.5 kW maximum demand, so a 10 kW three-phase load instead of the current 5 kW.

Quick facts

Frequently asked questions

What is the difference between connected load and sanctioned load?

Connected load is everything you have wired in; sanctioned load is what the discom agreed to supply.

What happens if I exceed my sanctioned load?

Many discoms charge a penalty or revise the load and fixed charges based on the recorded maximum demand.

How much load does an EV charger need?

A typical 3.3 kW home charger adds about 3.3 kW; a 7.4 kW charger often needs three-phase supply.

Do fixed charges depend on sanctioned load?

Yes. Most tariffs charge fixed charges per kW of sanctioned load each month.

How do I increase my sanctioned load?

Apply on your discom's website or office, pay the fee and allow an inspection.

Is anything uploaded?

No. It runs in your browser.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages