Gauge R&R Calculator (MSA)
Paste the study data (operator, part, trial readings), the tolerance and reference readings to get EV, AV, GRR, PV, %GRR, ndc and gauge capability indices.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Run the study
Operators measure parts several times.
- 2Paste the data
Operator, part, readings per line.
- 3Enter the tolerance
For % of tolerance.
- 4Enter reference readings
For Cg and Cgk.
- 5Read the results
%GRR, ndc and decision.
About this tool
Before trusting measurements for process control, manufacturers check whether the measurement system itself is good enough. A gauge repeatability and reproducibility (R&R) study has several operators measure the same parts several times. The variation is split into repeatability (equipment), reproducibility (operators) and part-to-part variation. This calculator applies the AIAG average and range method and adds the gauge capability indices Cg and Cgk from repeated measurements of a reference part.
Who this is for
Quality engineers, metrologists, Six Sigma practitioners and automotive suppliers following IATF 16949 and the AIAG core tools.
Study design
A typical study uses 10 parts, 3 operators and 2 or 3 trials. Enter one line per operator and part: operator number, part number, then the readings. The calculator supports 2 or 3 trials, 2 or 3 operators and 2 to 10 parts.
The components
- **EV (equipment variation, repeatability)** = R̄ × K₁, from the average range of repeat readings. - **AV (appraiser variation, reproducibility)** = √((x̄_diff × K₂)² − EV²/(n r)), from the difference between operator averages. - **GRR** = √(EV² + AV²). - **PV (part variation)** = R_p × K₃, from the range of part averages. - **TV (total variation)** = √(GRR² + PV²). K₁, K₂ and K₃ are the AIAG constants for the numbers of trials, operators and parts.
Acceptance
| %GRR | Decision | |---|---| | < 10 % | Acceptable | | 10–30 % | Marginal, may be acceptable depending on use and cost | | > 30 % | Unacceptable | The number of distinct categories ndc = 1.41 × PV / GRR should be at least 5.
Percent of tolerance
When the gauge is used to accept or reject parts, compare 6 × GRR with the tolerance (precision-to-tolerance ratio, P/T).
Cg and Cgk
Type 1 gauge studies (VDA 5, Bosch Booklet 10) measure one reference part about 25–50 times. Cg = 0.2 T / (6 s) compares 20 % of the tolerance with the gauge spread; Cgk also accounts for bias. Both should be at least 1.33.
Good practice
Choose parts that span the real process range, randomise the measurement order and hide part identities from operators.
Improving a measurement system
If repeatability (EV) dominates, look at the gauge: wear, fixturing, resolution, cleanliness, temperature. If reproducibility (AV) dominates, look at the people: training, clear instructions, consistent clamping force and reading technique. Re-run the study after changes to confirm the improvement.
Resolution rule of thumb
The gauge should resolve at least one tenth of the tolerance or of the process spread (the 10-to-1 rule).
Keep the study records with the gauge's calibration file.
Worked example
Three operators measure five parts twice. EV = 0.038 (16.9 % of TV), AV = 0.035 (15.2 %), GRR = 0.052 (22.7 %, marginal) and PV = 0.222. ndc = 6, so the system distinguishes parts adequately. Against a tolerance of 1.0, 6·GRR is 31 % of the tolerance. Ten readings of a reference part with tolerance 0.05 give Cg = 1.76 and Cgk = 1.65.
Limits
Average and range method only; the ANOVA method also separates operator-part interaction. Not an official PPAP document.
Worked example
Three operators, five parts and two trials give %GRR = 22.7 % and ndc = 6.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: AIAG Measurement Systems Analysis (MSA, 4th edition) average and range method: EV = R̄·K₁, AV = √((x̄_diff·K₂)² − EV²/(nr)), GRR = √(EV² + AV²), PV = R_p·K₃, TV, %GRR, ndc = 1.41·PV/GRR; acceptance < 10 %, 10–30 %, > 30 %; gauge capability Cg = 0.2T/(6s) and Cgk = (0.1T −
Frequently asked questions
What is gauge R&R?
A study of measurement variation from equipment and operators.
What %GRR is acceptable?
Below 10 %; 10–30 % may be acceptable depending on use.
What is ndc?
The number of distinct categories the gauge can separate; at least 5.
What are Cg and Cgk?
Gauge capability indices from repeated measurements of a reference.
How many parts should I use?
Usually 10, covering the process range.
Is my data stored?