Gauge R&R Calculator (MSA)

Paste the study data (operator, part, trial readings), the tolerance and reference readings to get EV, AV, GRR, PV, %GRR, ndc and gauge capability indices.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Run the study

    Operators measure parts several times.

  2. 2
    Paste the data

    Operator, part, readings per line.

  3. 3
    Enter the tolerance

    For % of tolerance.

  4. 4
    Enter reference readings

    For Cg and Cgk.

  5. 5
    Read the results

    %GRR, ndc and decision.

About this tool

Before trusting measurements for process control, manufacturers check whether the measurement system itself is good enough. A gauge repeatability and reproducibility (R&R) study has several operators measure the same parts several times. The variation is split into repeatability (equipment), reproducibility (operators) and part-to-part variation. This calculator applies the AIAG average and range method and adds the gauge capability indices Cg and Cgk from repeated measurements of a reference part.

Who this is for

Quality engineers, metrologists, Six Sigma practitioners and automotive suppliers following IATF 16949 and the AIAG core tools.

Study design

A typical study uses 10 parts, 3 operators and 2 or 3 trials. Enter one line per operator and part: operator number, part number, then the readings. The calculator supports 2 or 3 trials, 2 or 3 operators and 2 to 10 parts.

The components

- **EV (equipment variation, repeatability)** = R̄ × K₁, from the average range of repeat readings. - **AV (appraiser variation, reproducibility)** = √((x̄_diff × K₂)² − EV²/(n r)), from the difference between operator averages. - **GRR** = √(EV² + AV²). - **PV (part variation)** = R_p × K₃, from the range of part averages. - **TV (total variation)** = √(GRR² + PV²). K₁, K₂ and K₃ are the AIAG constants for the numbers of trials, operators and parts.

Acceptance

| %GRR | Decision | |---|---| | < 10 % | Acceptable | | 10–30 % | Marginal, may be acceptable depending on use and cost | | > 30 % | Unacceptable | The number of distinct categories ndc = 1.41 × PV / GRR should be at least 5.

Percent of tolerance

When the gauge is used to accept or reject parts, compare 6 × GRR with the tolerance (precision-to-tolerance ratio, P/T).

Cg and Cgk

Type 1 gauge studies (VDA 5, Bosch Booklet 10) measure one reference part about 25–50 times. Cg = 0.2 T / (6 s) compares 20 % of the tolerance with the gauge spread; Cgk also accounts for bias. Both should be at least 1.33.

Good practice

Choose parts that span the real process range, randomise the measurement order and hide part identities from operators.

Improving a measurement system

If repeatability (EV) dominates, look at the gauge: wear, fixturing, resolution, cleanliness, temperature. If reproducibility (AV) dominates, look at the people: training, clear instructions, consistent clamping force and reading technique. Re-run the study after changes to confirm the improvement.

Resolution rule of thumb

The gauge should resolve at least one tenth of the tolerance or of the process spread (the 10-to-1 rule).

Keep the study records with the gauge's calibration file.

Worked example

Three operators measure five parts twice. EV = 0.038 (16.9 % of TV), AV = 0.035 (15.2 %), GRR = 0.052 (22.7 %, marginal) and PV = 0.222. ndc = 6, so the system distinguishes parts adequately. Against a tolerance of 1.0, 6·GRR is 31 % of the tolerance. Ten readings of a reference part with tolerance 0.05 give Cg = 1.76 and Cgk = 1.65.

Limits

Average and range method only; the ANOVA method also separates operator-part interaction. Not an official PPAP document.

Worked example

Three operators, five parts and two trials give %GRR = 22.7 % and ndc = 6.

Quick facts

Frequently asked questions

What is gauge R&R?

A study of measurement variation from equipment and operators.

What %GRR is acceptable?

Below 10 %; 10–30 % may be acceptable depending on use.

What is ndc?

The number of distinct categories the gauge can separate; at least 5.

What are Cg and Cgk?

Gauge capability indices from repeated measurements of a reference.

How many parts should I use?

Usually 10, covering the process range.

Is my data stored?

No. Everything is calculated in your browser.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages