Forklift Daily Pre-Use Inspection Checklist

Pick the truck, enter the operator and hour meter, tick any of the 14 checks that failed, describe the defect and add photos, mark the truck safe or out of service, print a DO NOT USE tag, and print a weekly check sheet for each truck.

Runs in your browser. Your files never leave your device. See how to check

…

How to do it

  1. 1
    Truck

    Choose the truck and enter the hour meter.

  2. 2
    Check

    Walk round and tick any failed item.

  3. 3
    Defect

    Describe it and add photos.

  4. 4
    Decide

    Mark safe or out of service.

  5. 5
    Print

    Print the tag or the weekly log.

About this tool

The Forklift Daily Pre-Use Inspection Checklist records the short check an operator makes at the start of each shift before driving a lift truck. UK guidance in HSE L117 and the US rule in OSHA 29 CFR 1910.178(q)(7) both expect trucks to be examined before use, with defects reported and unsafe trucks taken out of service. The checklist has fourteen items covering the main visual and operational points: forks, carriage and chains free of cracks or damage, mast and hydraulic hoses free of leaks, tyres and wheels, brakes and parking brake, steering, horn, lights, beacon and reversing alarm, seat belt and seat, overhead guard and load backrest, controls returning to neutral, fluid levels, fuel (LPG cylinder secure with no smell of gas, or diesel level), the battery for electric trucks (charged, connector undamaged, no electrolyte leaks), a readable data plate and the fire extinguisher where one is fitted. The operator ticks only the checks that failed, adds defect details and photos, and chooses whether the truck is safe to use or out of service. A repaired field records when and by whom the defect was fixed. The truck list starts with an electric counterbalance, an LPG truck, a diesel truck and an electric reach truck. Each check prints as a red DO NOT USE out-of-service tag showing the truck, the defect, who reported it and when, and a line for the repairer to sign.

Who this is for

Warehouse and logistics managers, forklift operators, transport and yard supervisors, maintenance teams who need a defect trail, and small businesses that have replaced paper check books.

How to use it

1. Set the site name and add your trucks to the truck list. 2. At the start of the shift, choose the truck and enter the operator and hour meter. 3. Walk round the truck and tick any check that failed. 4. Describe the defect, add photos and decide whether the truck is safe to use. 5. Print the out-of-service tag for a defective truck and the weekly log each Friday.

What the sample shows

The example covers two trucks at Warehouse B over two days. On 2 November FLT-01, an electric truck, passed every check at 4,120 hours. The same morning S. Ali found the reversing alarm on LPG truck FLT-02 not working, ticked the horn, lights, beacon and alarm check and marked the truck out of service; the repair was signed off on 3 November by a service engineer. On 3 November both trucks passed. The stat cards show 4 checks, 0 trucks out of service once the repair is recorded and 1 check with faults. If no check has been entered for a truck today, the insights panel says so.

Weekly log

The Summary tab groups checks by week and truck, starting on a Monday, so the sample gives one group for each truck for the week of 2 November. Each group prints a weekly check sheet with the fourteen checks down the side, one column per day marked with a tick or a cross, and the operator's name under each day. Keep the printed sheet with the truck or file it with your maintenance records.

Warnings

When a check records failed items but the truck is still marked safe to use, the insights panel asks you to confirm the decision with a supervisor. A missing check for any truck is also listed, which helps supervisors see at a glance which trucks have not been checked.

Limits

A daily pre-use check does not replace the thorough examination required under LOLER and PUWER, or planned servicing by a competent engineer; record those separately. The checklist items are a general list, so add the points from your truck manufacturer's handbook and attachments. Data stays in this browser, so export the CSV or JSON backup regularly. This checklist is not legal or safety advice.

Worked example

FLT-02 (LPG), 2 November: reversing alarm failed, marked out of service, repaired 3 November. Sample totals 4 checks, 1 with faults, 0 trucks still out of service.

Quick facts

Frequently asked questions

How often should a forklift be checked?

Before use at the start of every shift, or every day for trucks used on one shift. OSHA requires an examination at least daily, and after each shift for round-the-clock use.

Does it cover gas, diesel and electric trucks?

Yes. The fuel check covers LPG cylinders and diesel levels, and the battery check covers electric trucks. Mark the item that does not apply as passed or note it in the details.

What should happen when a check fails?

Report the defect, decide with a supervisor whether the truck is safe, and if not, mark it out of service and fix the printed DO NOT USE tag until it is repaired.

What does the weekly log show?

One sheet per truck per week with every check down the side and a tick or cross for each day, plus the operator's name.

Is this the same as a thorough examination?

No. The thorough examination is a periodic inspection by a competent person under LOLER, usually every 6 or 12 months. A pre-use check is the operator's daily walk-round.

Can operators use it on a phone?

Yes. The form works in a mobile browser and photos can be taken directly. Records are saved in that phone's browser, so use one shared device or merge exports.

Guides for this tool

Completely freeNo cost, no sign-up
Files stay privateEverything runs in your browser
Easy in your languageAvailable in many languages