Venturi Meter Flow Calculator
Calculate flow rate, velocities and throat pressure of a Venturi tube from the pressure drop, with a cavitation check.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Step 1: Open Venturi Meter Flow Calculator and add your input
Type your numbers or text, add your file, or pick the options you need. Nothing is uploaded: everything stays in your browser.
- 2Step 2: What Venturi Meter Flow Calculator does
Calculate flow rate, velocities and throat pressure of a Venturi tube from the pressure drop, with a cavitation check.
- 3Step 3: Read the result and compare
The result appears at once. Change one value to see how the answer moves, then keep the figure that fits your case.
- 4Step 4: Copy or save it
Copy the result or download it. For an important decision, confirm it with the official source or an adviser.
About this tool
Enter the pipe and throat diameters, the measured pressure drop, the fluid density, the discharge coefficient and, optionally, the inlet pressure and vapour pressure. The calculator gives the flow rate, the velocities at both ends, the throat pressure and whether the throat pressure stays above the vapour pressure.
Formula
Q = C_d A₂ √(2ΔP ÷ (ρ(1 − β⁴))) with β = d₂ ÷ d₁, from Bernoulli's equation and continuity. C_d is typically 0.95 to 0.99 for a classical Venturi.
Cavitation
The throat pressure is p₁ − ΔP. If it falls to the vapour pressure of the liquid (2.34 kPa for water at 20 °C) vapour bubbles form and the reading is no longer valid.
Worked example
A 100 mm pipe with a 50 mm throat and a 30 kPa drop in water carries 15.41 L/s (55.5 m³/h), with 1.96 m/s in the pipe and 7.85 m/s at the throat.
Tips for best results
Check every box before you rely on a result, because one wrong digit changes the whole answer. Use the exact figures from your payslip, bill, certificate or contract, and keep a note of the date you calculated. Rates, thresholds and rules change from time to time, so for tax, fees and legal matters treat the output as an estimate and confirm with the official source named on this page. You can run as many scenarios as you like; nothing is saved or sent, and refreshing the page clears the boxes.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in many languages.
- Content last reviewed:
Frequently asked questions
What is the discharge coefficient?
A factor around 0.98 that accounts for friction losses.
What if the pressure is absolute or gauge?
Use absolute pressures for the cavitation check.
What fluids work?
Incompressible liquids; gases need a correction.
Which diameters?
The throat must be smaller than the pipe.
