Extension Cord Gauge and Load Calculator
List the tools on the cord, enter its length and the supply voltage, and see which AWG or mm² cord keeps voltage drop low and stays within its current rating.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Pick the system
Choose North America (AWG, 120 V) or Metric (mm², 230 V).
- 2Enter the cord
Type the length, unit, plug rating and conductor temperature.
- 3Add the tools
Use the typical-load buttons or add your own devices and watts.
- 4Tick what runs together
Only ticked devices count towards the load.
- 5Read the result
Check the minimum cord, drop, rating and heat tiles and the comparison table.
- 6Print or save
Press Report or CSV, and save the setup as a scenario.
About this tool
An extension cord that is too thin for its length and load causes two problems. The first is voltage drop: a long run of thin copper loses volts, so a saw slows down under load, a compressor struggles to start and motors run hotter than they should. The second is heat: every ampere through the resistance of the cord turns into warmth along its whole length, and if the cord is still wound on a reel that heat has nowhere to go. Packaging labels help only a little, because they rarely say how far you can go before the drop becomes a problem. This calculator starts from what you actually plug in. Add tools from a list of typical wattages or type your own, tick the ones that run together, and enter the cord length and supply voltage. It works out the current, the voltage drop on the round trip through both conductors, and the heat in the cord, for every common size: 18 to 10 AWG for North American 120 V cords and 0.75 to 4 mm² for 230 V cords. It marks the thinnest cord that stays inside both its current rating and your drop target, and warns about coiled reels.
Voltage drop
Current flows out on one conductor and back on the other, so the resistance that matters is twice the cord length. Drop = I × R, shown in volts and as a percentage of the supply. The NEC informational note suggests no more than 3 % on a branch circuit and 5 % in total; for a cord feeding a motor tool, 3 % is a good target. The conductor temperature input lets you allow for a cord that is warm in the sun or already loaded.
Current rating
Each size has a current limit. For AWG cords the tool uses the two-conductor column of NEC Table 400.5(A)(1); for metric cords, BS 7671 Table 4F3A. The plug and socket rating caps both: a 14 AWG cord with a 15 A plug is a 15 A cord. If the current is over the limit, a heavier cord is needed even when the drop is small.
Coiled reels
A cord on a reel cannot shed heat. Cable reels built to IEC 61242 carry two ratings on the label, one coiled and one fully unwound, and the coiled one is much lower. If you choose the coiled option, the tool shows the heat trapped in the drum and reminds you to unwind it.
Tool loads and motor starting
The tool list gives typical nameplate wattages for saws, grinders, vacuums, heaters, pressure washers and more. Your own tool's label is better. Motors draw several times their running current for a moment when they start, which is why a long cord that looks fine on paper can still make a saw bog down.
Limits
Not a substitute for a licensed electrician's advice or the cord maker's ratings. The marked rating on the cord and reel always takes precedence. Damaged, flat or undersized cords should be replaced, not calculated around. Outdoor use needs cords rated for outdoor conditions and RCD or GFCI protection.
Worked example
On a 120 V site a circular saw of 1,400 W and a 50 W work light run on a 100 ft cord, together drawing 12.1 A. A 16 AWG cord has 2 × 30.5 m × 13.17 Ω/km = 0.80 Ω at 20 °C and about 0.87 Ω at 40 °C, dropping 10.5 V, 8.7 %, and its 13 A rating is close, so it fails. A 14 AWG cord drops about 6.6 V, 5.5 %, also too much for a 3 % target. A 12 AWG cord drops about 4.1 V, 3.5 %, still over 3 % but under 5 %, and 10 AWG brings it to 2.2 %. For a 3 % target the choice is 10 AWG, or a shorter run of 12 AWG.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: NFPA 70 NEC Table 400.5(A)(1) and 210.19; BS 7671 Table 4F3A; IEC 61242
Frequently asked questions
What gauge extension cord do I need for 15 amps?
Up to about 25 ft, 14 AWG carries 15 A. For 50 ft use 12 AWG, and for 100 ft use 10 AWG if you want to keep the drop near 3 %. The calculator gives the exact figure for your length and load.
Why is a lower AWG number thicker?
The American Wire Gauge counts the drawing steps used to make the wire, so thinner wire has a higher number. Each step of three gauges roughly halves the area and doubles the resistance.
Does voltage matter?
Yes. The same tool draws about half the current at 230 V that it does at 120 V, so the drop in percent is about a quarter on the same cord. That is why 230 V countries use thinner cords for the same tools.
Is it dangerous to use a coiled cord reel?
It can be. A coiled reel at high load can overheat and melt its insulation. Unwind the reel fully whenever the load is above the coiled rating printed on it.
Can I join two extension cords?
It is best avoided. The total length adds to the drop, and each joint adds resistance and a weak point. Use one cord of the right length and gauge.
Are my tool lists saved?
Yes, in this browser, with named scenarios and a JSON backup. Nothing is uploaded.