Transformer Turns Ratio and Current Calculator
Calculate the turns ratio and the primary and secondary currents of a transformer.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Step 1: Open Transformer Turns Ratio and Current Calculator and add your input
Type your numbers or text, add your file, or pick the options you need. Nothing is uploaded: everything stays in your browser.
- 2Step 2: What Transformer Turns Ratio and Current Calculator does
Calculate the turns ratio and the primary and secondary currents of a transformer.
- 3Step 3: Read the result and compare
The result appears at once. Change one value to see how the answer moves, then keep the figure that fits your case.
- 4Step 4: Copy or save it
Copy the result or download it. For an important decision, confirm it with the official source or an adviser.
About this tool
Enter the primary and secondary voltages, the rating in kVA and the efficiency. The calculator gives the turns ratio, the primary and secondary currents and the input power.
Formulas
Turns ratio a = Np ÷ Ns = Vp ÷ Vs. Rated current I = VA ÷ V on each side. For a given load the secondary current is the load power divided by the secondary voltage, and the primary current is smaller by the ratio.
Use
The rating is the apparent power in kVA the transformer can deliver. Input power is higher than the output by the losses: input = output ÷ efficiency.
Note
Single-phase calculation. For three-phase divide the kVA by √3 × voltage.
Worked example
A 1 kVA transformer from 230 V to 12 V has a turns ratio of 19.17:1, a rated primary current of 4.35 A and a secondary current of 83.3 A. At 95% efficiency the input is 1.053 kVA.
Tips for best results
Check every box before you rely on a result, because one wrong digit changes the whole answer. Use the exact figures from your payslip, bill, certificate or contract, and keep a note of the date you calculated. Rates, thresholds and rules change from time to time, so for tax, fees and legal matters treat the output as an estimate and confirm with the official source named on this page. You can run as many scenarios as you like; nothing is saved or sent, and refreshing the page clears the boxes.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in many languages.
- Content last reviewed:
Frequently asked questions
What does the turns ratio mean?
The ratio of primary to secondary windings, equal to the voltage ratio.
Which current is larger?
The secondary current in a step-down transformer.
Is it for three-phase?
Divide by √3 for line currents.
What about regulation?
Voltage drops under load; not included.