Three-Phase Power Calculator
Calculate real, apparent and reactive power of a three-phase load from voltage, current and power factor.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Step 1: Open Three-Phase Power Calculator and add your input
Type your numbers or text, add your file, or pick the options you need. Nothing is uploaded: everything stays in your browser.
- 2Step 2: What Three-Phase Power Calculator does
Calculate real, apparent and reactive power of a three-phase load from voltage, current and power factor.
- 3Step 3: Read the result and compare
The result appears at once. Change one value to see how the answer moves, then keep the figure that fits your case.
- 4Step 4: Copy or save it
Copy the result or download it. For an important decision, confirm it with the official source or an adviser.
About this tool
Enter the line-to-line voltage, the line current and the power factor. The calculator gives the apparent power in kVA, the real power in kW, the reactive power in kvar and the phase angle.
Formulas
Apparent power S = √3 × V × I. Real power P = S × power factor. Reactive power Q = √(S² − P²). The phase angle is arccos(power factor).
Use
The formulas apply to a balanced three-phase load with V the line-to-line voltage and I the line current. Generators, transformers and cables are rated in kVA; energy is billed in kWh of real power.
Note
Unbalanced loads need each phase calculated on its own.
Worked example
At 400 V and 50 A with a power factor of 0.85, the load draws 34.64 kVA, 29.45 kW and 18.25 kvar at a phase angle of 31.8°.
Tips for best results
Check every box before you rely on a result, because one wrong digit changes the whole answer. Use the exact figures from your payslip, bill, certificate or contract, and keep a note of the date you calculated. Rates, thresholds and rules change from time to time, so for tax, fees and legal matters treat the output as an estimate and confirm with the official source named on this page. You can run as many scenarios as you like; nothing is saved or sent, and refreshing the page clears the boxes.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in many languages.
- Content last reviewed:
Frequently asked questions
Which voltage do I use?
The line-to-line voltage, such as 400 V in Europe.
What is power factor?
The ratio of real power to apparent power.
Is it for single phase?
No. Single-phase power is V × I × PF.
Why kVA and kW?
kVA includes reactive power that does no useful work but loads the supply.