DICOM Viewer (CT, MRI and X-Ray Files)
Open the .dcm files on a hospital CD or in a download folder, scroll through each series, adjust window and level, measure lengths, angles and regions, read every tag, save anonymised copies and export a PNG or an MP4 clip. For viewing only, never for diagnosis.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Open the files
Tap Open a folder and choose the DICOM folder on the disc, or pick single .dcm files.
- 2Pick a series
Choose a series from the list; the slices are sorted by position.
- 3Scroll and adjust
Scroll with the wheel, arrow keys or slider, and drag to set window and level or tap a preset.
- 4Measure
Choose Length, Angle or Ellipse ROI and draw on the image; results are listed and can be undone.
- 5Read tags
Search the tag table for a name, a tag number such as 0028,0030 or a value.
- 6Export
Save a PNG, an MP4 of the series, or anonymised copies as a ZIP.
About this tool
After a scan, many patients leave with a CD or a download link full of files with odd names and no extension. Those are DICOM files, the standard format of CT, MRI, X-ray, ultrasound and mammography machines, and most computers have no program that opens them. This viewer reads them directly in your browser. Choose single files or point it at the whole folder from the disc: it skips index and help files, groups the images into series by their series ID and sorts the slices by their position in the body, so a CT stack scrolls from head to feet in the right order. Drag on the picture to change brightness and contrast (window and level), or tap a preset such as soft tissue, lung, bone or brain. Zoom with two fingers or the buttons, pan, rotate and flip. The length tool uses the pixel spacing stored in the file, so a line shows millimetres; the angle tool and the ellipse tool, which gives the mean and spread of the values inside it, work the same way. Every tag can be searched, and the anonymiser writes new copies with the name, ID, birth date and staff fields blanked.
What files it can read
Uncompressed images in implicit or explicit little endian, explicit big endian and deflated files, RLE lossless, lossless JPEG (the common 1.2.840.10008.1.2.4.70 syntax used on many CDs), baseline JPEG and JPEG 2000 are decoded. JPEG 2000 needs a decoder of about 420 KB that downloads once when the first such image appears. JPEG-LS and 12-bit JPEG Extended images are not decoded yet; their tags still show. Multi-frame files such as ultrasound loops and cine MRI scroll frame by frame.
Window, level and values
CT values are shown in Hounsfield units after the rescale slope and intercept in the file. The window width sets how wide a range of values spans black to white and the level sets its centre. The hover read-out shows the pixel value under the pointer.
Anonymising
The copies keep the pixel data and transfer syntax untouched and change the patient name and ID to your text, blank the birth date, addresses, phone, institution and staff names, can drop private vendor tags and can replace the study, series and image UIDs with new ones that still keep the series together. Text burned into the pixels is not removed.
Limits
This is a file viewer for patients, students and teachers. It is not a medical device and not for diagnosis: the screen, the compression of exports and missing calibration make it unsuitable for clinical reading, and nothing here interprets an image. Ask the radiologist or your doctor about the report.
Worked example
A patient receives a CD after a knee MRI. The folder DICOM holds 412 files without extensions. Opening the folder gives four series: localiser (3 images), sagittal PD (28), coronal T1 (24) and axial T2 (30); 327 other files are reports and index files and are skipped. On the sagittal series, image 14 of 28, the pixel spacing is 0.3125 × 0.3125 mm, so a line drawn across the kneecap reads 41.6 mm. The patient saves image 14 as PNG and an MP4 of the 28 slices at 8 frames per second, then makes an anonymised ZIP with the name ANONYMOUS and the ID CASE001 to share with a physiotherapy class.
Quick facts
- Category: Images
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: DICOM standard PS3.5 (encoding) and PS3.15 Annex E (basic de-identification profile), NEMA; a file viewer, not for diagnosis
Frequently asked questions
Can I use this to find out what is wrong?
No. It only displays the pictures and the information stored with them. Reading a scan needs a trained radiologist, the full set of images on a calibrated screen and your history. Use the written report from the hospital and ask your doctor.
Why does the CD show more files than images?
Discs also carry a DICOMDIR index, a viewer program, structured reports and sometimes presentation states. Files that are not images are skipped or show only their tags. The count of skipped files appears under the series list.
Is anything uploaded?
No. The files are read with JavaScript in this browser tab. The only downloads are the program itself, the JPEG 2000 decoder when such images appear and the video encoder when you export an MP4.
Why are my lengths in pixels?
The file has no Pixel Spacing or Imager Pixel Spacing tag. Some secondary captures and screenshots stored as DICOM lose it. Without spacing the tool cannot convert to millimetres, so it shows pixels.
Does anonymising remove the name printed on the picture?
No. Older ultrasound, endoscopy and screen captures sometimes have the name burned into the pixels. The anonymiser only edits tags. Look through every image and crop or blank such text before you share the files.
Which window should I use for a CT?
The presets are common starting points: soft tissue 40 and 400, lung -600 and 1500, bone 400 and 1800, brain 40 and 80. Drag to fine-tune. The From file button returns to the window the scanner stored.