Carton Compression and Stacking Calculator (McKee)
Enter the board's edge crush test value and thickness, the box size and its gross weight, then choose humidity, storage time and stacking pattern to estimate box compression strength and how many boxes can safely be stacked.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1Enter board data
ECT and caliper.
- 2Enter box size
Length, width, height.
- 3Enter box weight
Gross kg.
- 4Choose conditions
Humidity, time, pattern.
- 5Read BCT and layers
Safe stack height.
About this tool
A corrugated box's job in a warehouse is to carry the weight of the boxes above it. Its laboratory box compression test (BCT) strength can be estimated from the edge crush test (ECT) of the board, the board thickness and the box perimeter with the McKee formula, which has been the industry's standard estimate for six decades. A box rarely sees laboratory conditions, though: humidity softens the paper, long storage causes creep, and misaligned or interlocked stacking moves the load away from the strong corners. This calculator multiplies BCT by those factors and works out how many layers can safely stand on the bottom box.
Who this is for
Packaging engineers, warehouse managers, exporters, box buyers and students of packaging technology.
The McKee formula
BCT = 5.874 × ECT × √(t × Z) with ECT in kN/m (N/mm), board caliper t and box perimeter Z = 2(L + W) in mm, giving BCT in newtons. The same constant works with lb/in and inches to give pounds-force. It applies to regular slotted cases; height has little effect between roughly 200 and 700 mm.
Typical board
| Board | Caliper | ECT | |---|---|---| | Single wall B flute | 3 mm | 4-6 kN/m | | Single wall C flute | 4 mm | 5-8 kN/m | | Double wall BC flute | 7 mm | 8-14 kN/m | In US terms, 32 ECT (lb/in) is 5.6 kN/m and 44 ECT is 7.7 kN/m.
Real-world factors
| Condition | Factor | |---|---| | Relative humidity 50 / 60 / 70 / 80 / 90 % | 1.00 / 0.91 / 0.81 / 0.68 / 0.50 | | Storage 1 / 10 / 30 / 100 / 365 days | 0.70 / 0.63 / 0.60 / 0.55 / 0.50 | | Column aligned / misaligned / interlocked / overhang | 0.90 / 0.75 / 0.50 / 0.65 | Multiplying them gives the share of BCT the box keeps; the inverse is the safety factor, often 3-5.
Worked example
A 400 × 300 × 300 mm box of 4 mm board with ECT 7 kN/m has a BCT of about 3,080 N (314 kgf). At 70 % RH, 30 days storage and column stacking, the factors give 0.44, so the box can carry 1,350 N. With 12 kg per box, 11 boxes can rest on the bottom one, a stack of 12 layers and 3.6 m.
Improving stack strength
- Stack in columns with corners aligned; interlocking halves strength. - Avoid pallet overhang, which leaves the box walls unsupported. - Use a higher ECT or double-wall board where storage is long or humid. - Let products share the load: rigid contents such as bottles carry part of the weight.
Common mistakes
- Using the burst (Mullen) rating, which measures puncture resistance rather than stacking strength. - Ignoring humidity: a box stored in a 90 % RH tropical warehouse has half its laboratory strength. - Forgetting the weight of pallets and boxes stacked above in multi-high pallet storage. - Applying McKee to trays, die-cut boxes or very tall boxes outside its range.
Limits
Estimates for regular slotted cases; test critical packages to ISO 12048 or ASTM D642. This is not professional packaging advice.
Worked example
400 × 300 mm box, 4 mm board, ECT 7 kN/m: BCT about 3,080 N; 12 layers of 12 kg boxes.
Quick facts
- Category: Engineering & Construction
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: McKee, Gander and Wachuta (1963) simplified formula BCT = 5.874 × ECT × √(caliper × perimeter); environmental and stacking factors from the Fibre Box Handbook and Kellicutt and Landt; ECT test to ISO 3037 and TAPPI T 839
Frequently asked questions
What is the McKee formula?
BCT = 5.874 × ECT × √(caliper × perimeter).
What is ECT?
Edge crush test, the board's compressive strength per length.
How much does humidity reduce strength?
About 19 % at 70 % RH and 50 % at 90 % RH.
Why does interlocked stacking weaken boxes?
Loads land between corners, where walls are weakest.
What safety factor is typical?
Between 3 and 5 for warehouse storage.
Is my data stored?
Box data is not recorded; it stays on this device.