Salinity, Specific Gravity and Conductivity: How They Relate
How to convert between ppt, specific gravity and conductivity using UNESCO seawater equations, why temperature matters and the right salinity for tanks.

Salinity, Specific Gravity and Conductivity: How They Relate
Marine aquarium keepers use hydrometers and refractometers that read specific gravity, oceanographers use conductivity meters, and fish farmers talk in parts per thousand. They are all measuring the same thing: how much salt is in the water. The salinity converter translates between them accurately.
Parts per thousand and PSU
Salinity is roughly the grams of dissolved salt in a kilogram of water. Natural sea water averages about 35 parts per thousand (ppt). Since 1978, oceanographers have defined salinity with the Practical Salinity Scale, measured from conductivity and expressed in practical salinity units (PSU). For practical purposes, PSU and ppt are the same.
Specific gravity
Specific gravity compares the density of the sample with that of pure water at the same temperature. Salty water is denser, so specific gravity rises with salinity: 35 ppt at 25 °C is about 1.0264. Because density changes with temperature, a hydrometer reading must be interpreted at the temperature it was taken or calibrated. The calculator uses the UNESCO EOS-80 equation of state, the standard formula for sea water density.
Conductivity
Dissolved salts conduct electricity. Conductivity meters read in millisiemens per centimetre; sea water at 35 ppt and 25 °C is about 53 mS/cm. Conductivity rises about 2% per degree, so meters usually correct to 25 °C. The calculator converts using the PSS-78 equations at your temperature.
Typical targets
Reef aquariums are usually kept at about 35 ppt, a specific gravity of 1.025 to 1.026. Fish-only marine tanks tolerate 30 to 35. Brackish species such as mollies and some puffers thrive around 5 to 15 ppt. Shrimp ponds often run at 10 to 25 ppt.
A worked example
A refractometer reads 1.0264 at 25 °C. The converter gives 35.0 ppt, a density of 1,023.4 kg/m³ and a conductivity of about 53 mS/cm: natural sea water strength.
Mixing and topping up
Mix salt into fresh water, let it dissolve and reach temperature, then measure and adjust. When water evaporates, the salt stays behind, so top up with fresh water.
Questions aquarium keepers ask
Which instrument is best? A calibrated refractometer or a conductivity meter is more reliable than a floating hydrometer. Why does my reading change during the day? Evaporation concentrates salt, and temperature affects the reading. How fast can I change salinity? Gradually, about 1 to 2 ppt a day for most animals. What about brackish species? They tolerate a range, but sudden changes still stress them.
Calibration
Calibrate refractometers with a 35 ppt standard solution rather than distilled water, because temperature compensation is less accurate far from the calibration point. Check conductivity meters with a standard solution every few months.
Shrimp and fish farming
Many farmed shrimp grow well at moderate salinities, and some fish are raised in brackish water to control disease. Monitoring salinity after heavy rain or during dry seasons helps avoid sudden changes.
Units at a glance
1 ppt is 1 gram of salt per kilogram of water, about 1,000 mg/L. Fresh water is below 0.5 ppt, brackish water roughly 0.5 to 30 ppt, sea water 30 to 40 ppt and hypersaline lagoons or salt ponds above 40 ppt. Specific gravity has no units, and conductivity is given in mS/cm or µS/cm (1 mS/cm = 1,000 µS/cm). For brackish aquariums and ponds, a conductivity meter with temperature compensation is the easiest way to track small changes, because hydrometers are least accurate at low salinities. Keeping a written log of readings, temperature and water changes makes trends easy to spot.
Limits
The equations are for natural sea water composition. Artificial salt mixes may differ a little.


&c=%23c2410c&k=education)