RC and LC Filters Explained: Cutoff Frequency and Bode Plots
How RC, RL and LC filters work, how to calculate cutoff and resonant frequency, what Q means, how to read a Bode plot and how many poles a filter needs.

RC and LC Filters Explained: Cutoff Frequency and Bode Plots
Filters shape which frequencies pass through a circuit. A simple resistor and capacitor can smooth a noisy sensor, an inductor and capacitor can pick out one radio frequency, and a higher-order filter can keep unwanted signals away from an analogue-to-digital converter. The free Filter Cutoff and Bode Plot Calculator calculates cutoff and resonant frequencies and draws the Bode plots that show a filter's behaviour across frequency.
First-order RC and RL filters
The simplest low-pass filter is a resistor in series with the signal and a capacitor to ground. Low frequencies pass; high frequencies are shunted away by the capacitor. Swap the parts and you get a high-pass filter.
The cutoff frequency, where the output has fallen by 3 dB (to about 70.7% of the input voltage), is:
- RC filter: fc = 1 / (2πRC)
- RL filter: fc = R / (2πL)
For 1.6 kΩ and 100 nF, fc is about 995 Hz. The time constant, τ = RC, also sets how quickly the filter responds to a step: the 10–90% rise time is 2.2τ.
Reading a Bode plot
A Bode plot has frequency on a logarithmic axis and two graphs:
- Magnitude in decibels. A first-order low-pass is flat below fc and falls at 20 dB per decade (6 dB per octave) above it.
- Phase in degrees. A first-order low-pass shifts the phase from 0° at low frequencies to −90° at high frequencies, passing −45° at fc.
The calculator also shows group delay, the time delay each frequency experiences. Constant group delay preserves the shape of pulses; a peak in group delay near the cutoff causes overshoot and ringing in square waves.
LC resonance and Q
An inductor and capacitor together resonate at f0 = 1 / (2π√(LC)). In a series RLC circuit the quality factor is Q = (1/R)√(L/C) and the bandwidth is f0/Q. High Q gives a sharp, selective peak, as in radio tuning; low Q gives a broad, damped response.
How many poles?
Each extra filter order adds 20 dB per decade of roll-off. To size a filter, specify:
- the passband edge and the maximum loss allowed there;
- the stopband edge and the minimum attenuation required.
The Butterworth order needed is n ≥ log10((10^(As/10) − 1) / (10^(Ap/10) − 1)) ÷ (2 log10(fs/fp)), rounded up. Butterworth filters have the flattest passband; Chebyshev filters are steeper for the same order but ripple, and Bessel filters keep pulses cleanest.
Practical tips
- A load on an RC filter's output changes its cutoff; buffer it with an op-amp follower.
- Capacitors often have 5 to 20% tolerance and change with temperature and voltage. Use C0G/NP0 types for small values in filters.
- Put anti-aliasing filters before ADCs, with the cutoff well below half the sample rate.
A worked example
Suppose a temperature sensor's signal is disturbed by 50 Hz mains hum, and the useful signal changes no faster than once a second. A low-pass filter with a cutoff around 5 Hz passes the temperature changes and reduces the hum by about 20 dB. With a 10 µF capacitor, the resistor needed is about 3.2 kΩ, giving a time constant of 32 ms. If 20 dB is not enough, a second-order filter gives 40 dB.
Step by step
- Choose RC, RL, LC or a Butterworth specification.
- Enter component values with their units.
- Read the cutoff or resonant frequency, Q and time constant.
- Study the magnitude, phase and group delay plots.
- Adjust values until the response meets your needs.
The calculator runs in your browser.