How to Check Whether a PDF Is Really PDF/A (and Fix What Fails)
What PDF/A is, the difference between 1b, 2b and 3b, the rules files most often break, and how to validate a PDF and fix it before archiving.
&c=%230f766e&k=documents)
How to Check Whether a PDF Is Really PDF/A
Universities ask for theses in PDF/A. Courts, land registries and national archives require it. Many companies keep accounts and contracts in it. PDF/A is the version of PDF built for the long term: a file that will open and look exactly the same in thirty years, on software that does not exist yet. The trouble is that a file can be called PDF/A, or even claim to be PDF/A in its metadata, and still break the rules. Archives then reject it, often weeks later. The free PDF/A Validator checks the rules that most often fail, in your browser, before you submit.
Why PDF/A has rules
An ordinary PDF can depend on the outside world. It might use a font installed on the author's computer, describe colours in a way that depends on the printer, run JavaScript, play a video or need a password. Any of these can fail in the future. PDF/A, defined in ISO 19005, forbids such dependencies: everything needed to show the pages must be inside the file and described precisely.
The levels
- PDF/A-1b (2005) is based on PDF 1.4. No transparency, no layers and no attachments. Some institutions still insist on it.
- PDF/A-2b (2011) is based on PDF 1.7 and allows transparency, layers, JPEG 2000 compression and attachments that are themselves PDF/A. It is the usual choice today.
- PDF/A-3b (2012) also allows any attachment, as long as its relationship to the document is declared. E-invoices such as ZUGFeRD and Factur-X use it to carry the invoice data as XML inside a readable PDF.
"b" stands for basic: the visual appearance is preserved. Levels "a" (accessible, tagged) and "u" (Unicode text) add further requirements.
The rules that fail most often
Fonts not embedded. The most common failure. Every font used must be inside the file. Word, PowerPoint and InDesign embed fonts when you use their PDF/A export option.
No output intent. If pages use device colours (plain RGB or CMYK), the file must include an ICC colour profile that says what those numbers mean.
Missing or wrong identification. The XMP metadata must state the part and conformance level. Renaming a file "thesis-pdfa.pdf" does not do this.
Transparency in PDF/A-1. Drop shadows, soft edges and semi-transparent images are not allowed in level 1. Use PDF/A-2b if your archive accepts it.
JavaScript and actions. Form calculations, launch actions and multimedia are forbidden.
Annotations without appearances. Comments must have a defined look and be set to print, or be flattened into the page.
Using the validator
- Load one or more PDFs.
- Choose the level to check against. If a file declares its level, that is used unless you turn the option off.
- Read the Summary table: what each file claims and whether any rule failed.
- Open the Rules table for details: the ISO clause, the result, the pages involved and a fix hint. Failing pages are marked on the preview.
- Download the CSV report to send to whoever made the file.
Fixing failures
The most reliable fix is to export again from the source document with a proper PDF/A option: in Word, File, Save As, PDF, Options, "PDF/A compliant"; in InDesign, choose a PDF/X or PDF/A preset; in LibreOffice, tick "Archive (PDF/A)". Converting an existing PDF in Acrobat's Preflight can also work. Avoid tools that only stamp the PDF/A label on without changing the file.
Validation you can rely on
This validator concentrates on the failures seen most in practice and checks them from the file structure. A full validator such as veraPDF, the reference used by many archives, tests hundreds of detailed conditions. If an institution asks for a formal validation report, run veraPDF on the final file after fixing what this tool finds. This guide is general information, not records-management or legal advice.


&c=%23b45309&k=from-pdf)