How to Open an IFC File Without BIM Software and Check What Is Inside
What an IFC model holds, how storeys, types, property sets and quantity sets fit together, and how to view one in 3D and export a schedule.

How to Open an IFC File Without BIM Software and Check What Is Inside
Sooner or later, anyone working near a building project receives a file ending in .ifc. The architect sends it to the structural engineer, the main contractor forwards it to a cladding subcontractor, or a client is told that the model is "in the shared folder". If you do not run Revit, ArchiCAD, Tekla or a similar program, the file can seem closed to you. It is not. IFC was designed as an open format, and its contents can be read and checked with a viewer that understands the structure.
What an IFC file actually is
IFC stands for Industry Foundation Classes, an international standard published by buildingSMART as ISO 16739. Most files you meet are in one of three schema versions: IFC2x3, still very common from older exports; IFC4, the current mainstream version; and IFC4x3, which adds roads, railways, bridges and other infrastructure.
Open an .ifc file in a text editor and you will find lines such as #215=IFCWALL(...). This is the STEP format. Each line is an entity with a number, and entities point at one another by those numbers. A wall points at its placement and its geometry, while separate relationship lines say which storey contains the wall, which wall type it belongs to and which property sets describe it.
Four ideas explain most of what you need to know:
- Spatial structure. A project contains a site, the site contains a building, and the building contains storeys. Elements are attached to a storey.
- Classes. Every element has a class such as IfcWall, IfcSlab, IfcDoor, IfcWindow or IfcBeam. This is what lets a model from one program be understood by another.
- Property sets. Named groups of values such as Pset_WallCommon, which holds standard fields like FireRating, IsExternal and ThermalTransmittance. Authoring programs and users can add their own sets too.
- Quantity sets. Groups whose names begin with Qto_, such as Qto_WallBaseQuantities, holding lengths, areas and volumes that the authoring program calculated at export.
Worked example
The IFC BIM Model Viewer comes with a sample house that shows all four ideas. It is an IFC4 file with a project called Sample house on a site named Plot 12, and its unit assignment declares metres.
The Storeys table lists Ground floor at elevation 0 and First floor at elevation 3, each with 9 elements. The Classes table counts 10 walls, 4 windows, 2 slabs, 1 door and 1 roof, which makes 18 elements built from 309 STEP entities.
Tap the south wall of the ground floor in the 3D view and the property panel opens. It reads Brick cavity wall 300 as the type and W1-S as the tag. From the quantity set come a length of 10, a height of 3, a net side area of 26.31 and a net volume of 8.46. The common property set gives REI 60 for fire rating, true for IsExternal and 0.18 for thermal transmittance.
Now look at the Totals table grouped by IFC class. The ten walls add up to 88 m of length, 242.04 m² of net side area and 65.28 m³ of net volume, and the two slabs to 160 m² of gross area. Switch the grouping to element type and the picture changes: the 8 external walls of type Brick cavity wall 300 total 197.82 m² of net side area, and the 2 internal partitions appear separately because the model gives them no type. That one switch is often the quickest way to spot elements that a designer forgot to assign.
To look inside the house, open Show / hide storeys and classes and untick First floor, or untick IfcSlab and IfcRoof to leave just the walls standing. Measure distance then gives the straight line between two picked points along with its vertical and horizontal parts.
Using the schedule
The Excel download holds sheets for elements, totals and storeys. Each element row keeps its GlobalId, the 22 character identifier that stays the same across exports, so you can match rows to a later revision of the model or to an issue raised in a coordination meeting. Property columns can be limited to the common sets, widened to every property, or dropped so that only quantities are left.
Common mistakes
Treating blank quantities as zero. An empty cell means the authoring program did not export a Qto set for that element. In the sample, windows, the door and the roof have no quantity sets, so they have counts but no areas. Ask for an export with base quantities switched on rather than assuming the area is nothing.
Mixing up units. The schedule reports values as stored. A model in millimetres gives a wall length of 10000 where a model in metres gives 10. Check the length unit in the summary before adding figures to a cost plan.
Reading the roof as part of the wrong storey. Elements are listed under the storey the model assigns them to. In the sample the roof belongs to First floor, which is a modelling choice, not an error in the viewer.
Sending an ifcZIP or IFC-XML file. Only plain .ifc text is read. Unzip an ifcZIP first, or ask for a standard export.
Relying on a coordination model for construction quantities. A model shows what the designer drew at a point in time. Use the schedule to check and question, then confirm figures with the responsible designer and the current drawings.
Privacy note
The model is parsed in your browser. The 3D view fetches the web-ifc engine and three.js from jsDelivr the first time it is opened, but your file is not uploaded, and the tables still work if that download is blocked.