Dew Point, Relative Humidity and Wet Bulb: How They Fit Together
Understand dew point, relative humidity, wet bulb and absolute humidity, the Magnus formula behind them, and how to convert between them with examples.

Dew Point, Relative Humidity and Wet Bulb: How They Fit Together
Weather apps show relative humidity, aviation reports give the dew point, an old sling psychrometer gives a wet-bulb reading, and an HVAC engineer talks about grams of water per kilogram of air. They all describe the same thing: how much water vapour is in the air. This guide explains how the measures are linked and how to convert between them with the humidity and dew point calculator.
Saturation vapour pressure: the key quantity
Air at a given temperature can only hold a certain amount of water vapour before it condenses. The pressure that vapour exerts at that limit is the saturation vapour pressure, es. It rises steeply with temperature: about 6.1 hPa at 0 °C, 12.3 hPa at 10 °C, 23.4 hPa at 20 °C and 42.5 hPa at 30 °C. Warm air can hold far more water.
Meteorologists usually calculate es with the Magnus formula. The coefficients published by Alduchov and Eskridge in 1996 are among the most accurate:
es = 6.1094 × exp(17.625 T / (T + 243.04)) hPa, with T in °C.
Between −40 and +50 °C this matches reference tables within about 0.3 percent. Other versions, such as Tetens (1930) or Buck (1981), give almost the same numbers; the calculator shows all of them side by side.
Relative humidity
Relative humidity (RH) is the actual vapour pressure e divided by the saturation vapour pressure, as a percentage: RH = 100 × e / es. Because es depends on temperature, RH changes during the day even when the amount of water stays the same. Cool morning air may show 90 percent; the same air warmed in the afternoon may show 45 percent.
Dew point
The dew point is the temperature to which the air must be cooled, at constant pressure and moisture, to reach saturation. It is found by inverting the Magnus formula for e. Unlike RH, the dew point does not change when air warms or cools without gaining or losing moisture. That makes it the best everyday measure of how humid the air feels.
Wet-bulb temperature
A thermometer wrapped in a wet wick cools by evaporation. The drier the air, the more it cools. The wet-bulb temperature lies between the dew point and the air temperature. The World Meteorological Organization psychrometer equation links them: e = es(Tw) − γ p (T − Tw), where p is pressure and γ a psychrometric constant. Because the equation cannot be solved directly for Tw, the calculator solves it numerically. It also shows the Stull (2011) formula, a popular shortcut for sea-level conditions.
Absolute humidity, mixing ratio and specific humidity
- Absolute humidity is the mass of water vapour per cubic metre: 216.7 × e / T(K) grams per cubic metre.
- Mixing ratio is grams of vapour per kilogram of dry air: 622 e / (p − e).
- Specific humidity is grams of vapour per kilogram of moist air: 622 e / (p − 0.378 e).
The mixing ratio stays constant as air rises without condensation, so meteorologists use it to follow air parcels.
Worked example
At 25 °C and 50 percent RH at sea level:
- es = 31.6 hPa and e = 15.8 hPa,
- dew point = 13.9 °C,
- wet bulb = 18.0 °C,
- absolute humidity = 11.5 g/m³,
- mixing ratio = 9.9 g/kg.
If the same air cools overnight to 14 °C, dew forms on grass and cars.
How humid does it feel?
Dew point is a good comfort guide: below 10 °C feels dry, 10 to 16 °C comfortable, 16 to 18 °C slightly humid, 18 to 21 °C humid, 21 to 24 °C very humid, and above 24 °C oppressive. Tropical air often has dew points above 24 °C.
Practical uses
- Building and painting: coatings and concrete should not be applied when surfaces are within about 3 °C of the dew point, because condensation spoils the finish.
- Indoor health: keeping RH between 40 and 60 percent limits mould growth and dust mites.
- Museums: stable humidity protects wood, paper and paintings.
- Weather: the gap between temperature and dew point predicts fog and cloud base.
Measuring well
Hygrometers drift over time; calibrate them with saturated salt solutions or a reference instrument. Psychrometers need airflow of at least 3 m/s over a clean, wet wick. At altitude, enter the actual station pressure.
Using the calculator
- Enter the air temperature.
- Choose whether you know RH, dew point or wet-bulb temperature.
- Enter that value and the air pressure.
- Read every other humidity measure and the comparison of formulas.
Limits