Reading a FASTQ Quality Report: Per-Base Quality, Adapters and Duplication
What each module of a FASTQ quality report means, how the pass, warn and fail flags are set, and a worked example with real numbers from a test file.

Reading a FASTQ Quality Report: Per-Base Quality, Adapters and Duplication
The first thing anyone does with fresh sequencing reads is look at their quality. A FASTQ file holds every read as four lines: a name starting with @, the bases, a plus line, and a string of characters where each one encodes the confidence in one base. A quality report turns millions of those strings into a few charts that show whether the run is usable and what needs trimming.
Phred scores and encodings
Each quality character is a Phred score plus an offset. A score Q means an error chance of 10 to the power −Q/10, so Q20 is one error in 100 and Q30 one in 1,000. Modern files add 33 to the score, so "I" is Q40 and "#" is Q2. Old Illumina pipelines (1.3 to 1.7) added 64 instead. The FASTQ Quality Report Viewer decides from the extremes: a lowest character below ";" means Phred+33, while a lowest of "@" or more together with a highest above "J" means Phred+64.
The modules
- Per-base quality: the mean, median, lower quartile and 10th percentile at each position, against lines at Q20 and Q28. Quality usually falls towards the end of reads.
- Per-read quality: how many reads have each mean score. A second bump at low scores often means a bad tile or bubbles.
- GC content: a histogram of GC percentage per read. A clean library of one organism gives one smooth hump.
- Read length: a single bar for untrimmed short reads, a spread after trimming.
- Base content: A, C, G, T and N at each position. Random libraries give flat lines after the first few bases.
- Adapter content: the share of reads that contain one of six known adapter sequences at or before each position.
- Duplication and over-represented sequences: how often identical starts repeat.
How the flags are set
The viewer gives each check a pass, warn or fail with fixed rules. Per-base quality fails when any position's lower quartile is under Q10 and warns when any median is under Q20. Adapter content fails above 10% by the last position and warns above 5%. N content fails above 20% at any position. A duplication level over 50% is a fail and over 20% a warning. Over-represented sequences fail when one passes 1% of the sample.
Worked example
A small test file of 100 reads makes the flags easy to follow. Every read is 50 bases. The first 40 quality characters are "I" (Q40) and the last ten "#" (Q2). Ninety reads share one sequence; ten others carry the Illumina Universal adapter AGATCGGAAGAG starting at base 11, and every read is padded out with C.
The summary shows 100 reads, 5,000 bases, read length 50 and Phred+33. Per-base quality is a fail: positions 41 to 50 have a lower quartile of Q2, so the detail reads "10 positions with lower quartile under Q10". Adapter content reaches exactly 10.0% at the last position, which is a warning rather than a fail because the fail line is above 10%. All that C padding gives a mean GC of 70.2%. With only two distinct starts among 100 reads, duplication is 98.0%, a fail, and the over-represented table lists both sequences at 90% and 10%, the second marked as a possible Illumina Universal adapter.
For a real run, the same picture would say: trim the last ten bases, remove the adapter, and expect a very low-complexity library.
Saving the report
HTML report writes one file with the summary, the flag table, every chart and the over-represented list, which can be attached to a lab notebook or an email. Print / PDF gives the same on paper, and Per-base CSV puts the numbers behind the quality chart into a spreadsheet. The file never leaves the browser.
Common mistakes
- Treating every fail as a problem. Amplicon, small RNA and bisulfite libraries fail base content or duplication by design.
- Reading a long-read file as if every position were covered. The per-position charts stop at base 500.
- Forgetting the read limit. The default is 500,000 reads; the report says when it stopped early, and the figures describe only those reads.
- Checking only one file of a pair. Open the R1 and R2 files one after the other; quality is often worse in R2.
- Trusting exact adapter matching alone. Adapters with sequencing errors in their first bases are not counted, so a trimmer may still find more.
A quick look like this does not replace a full pipeline, but it answers the first question, whether the reads are worth the next step, in a minute.



