Keeping a Useful Record of Engine Ground Runs
What to write down on every engine ground run, how to check readings against limits, and why trends matter, with an EGT exceedance example.

Keeping a Useful Record of Engine Ground Runs
Engine ground runs are routine for a powerplant team: leak checks after a component change, power assurance checks, vibration surveys and troubleshooting runs. Because they are routine, the record is often thin, a line in the technical log saying "ground run satisfactory". A slightly fuller personal record pays off when a reading creeps up over months, or when someone asks what the oil pressure was on the last run.
Before the run
Every run starts with the engine manual's procedure, not with memory. The essentials are usually the same:
- Authorisation: only people trained and authorised for that type and power setting run engines.
- Area: intake and exhaust danger areas clear, chocks in, brakes set, fire cover and an observer in place where required.
- Limits to hand: start, transient and steady-state limits for EGT or ITT, N1 or rpm, oil pressure and temperature, and vibration.
- Communications agreed with the observer, including the abort signal.
What to record
A useful run record holds:
- Aircraft, engine position, date and reason for the run.
- Run time and the highest power setting reached.
- Peak EGT or ITT and peak N1 or rpm.
- Oil pressure at power and oil temperature.
- Vibration readings if measured.
- Findings, including any leak and where it was.
- Who ran the engine and who provided fire cover.
Peak values matter most because they are what limits are written against. Write the figure you saw, not "normal".
Checking against limits
Most engine manuals give several limits for the same parameter: a start limit, a time-limited transient limit and a steady-state maximum, and some include a table of actions for each band of exceedance. When you check a run, compare each peak reading with the right limit for the phase in which it occurred. If a reading goes over, it is an exceedance and the manual's action applies, which may be anything from a logbook entry to an inspection or engine removal.
A worked example
Two runs are logged with the limits set at 750°C EGT, 25 to 100 psi oil pressure and 101% N1.
- G-ABCD, single engine, leak check after a fuel pump change: 12 minutes, partial power, peak EGT 690°C, 96% N1, oil pressure 62 psi, oil temperature 78°C. No leaks. Within limits.
- ZZ201, engine 1, vibration survey: 25 minutes up to take-off power, peak EGT 758°C, N1 100.5%, oil pressure 70 psi, vibration 0.8 units.
The second run's EGT is 8°C above the steady limit used for the check, so it is flagged as an EGT exceedance. Now the manual's full table matters: if 758°C occurred for a few seconds during acceleration and the transient limit is higher, it may be acceptable with a record; if it was a stabilised reading, an exceedance procedure probably applies. The total run time for the two runs is 37 minutes, or 0.6 hours, which some operators also track against engine time.
Look at the trend
A single run inside limits says the engine was fine that day. A series of runs at similar power, with peak EGT rising from 700 to 715 to 730°C over a few months, says something is changing: compressor fouling, a sensor drifting, or a hot section issue developing. Plotting the peaks by aircraft makes that drift easy to see long before a limit is reached.
Common mistakes
- Writing "satisfactory" instead of the actual readings.
- Comparing a start peak with the steady-state limit, or the other way round.
- Not naming the person who ran the engine or provided fire cover.
- Forgetting the reason for the run, which makes the record hard to interpret later.
- Treating a reading just under the limit as nothing to note.
- Logging leaks without saying where they were.
This is general training content, not powerplant advice; the engine maintenance manual's procedures and limits always apply.
Using the engine ground run log
The shobfree.com Engine Ground Run Log keeps runs by tail and engine position, including APU. Set your EGT or ITT limit, oil pressure band and maximum N1 or rpm, and each run is marked within limits or exceeded with the parameter named. It totals runs, run time and exceedances, charts peak EGT per tail against the limit, prints a run record with signature lines, and exports CSV or a JSON backup. It is a personal log in your browser, not an approved maintenance record.