How Decibels Work: Adding Levels, Ratios and dB References
Why decibels are logarithmic, how to add and average sound levels, the difference between 10 log and 20 log, and what dB SPL, dBm, dBV and dBu mean.

How Decibels Work: Adding Levels, Ratios and dB References
Two vacuum cleaners at 70 dB each do not make 140 dB; they make 73 dB. Decibels confuse many people because they are logarithmic. Once you see why, adding, averaging and converting levels becomes straightforward. This guide explains the rules, and you can apply them with the decibel calculator.
Why logarithms?
Human hearing spans an enormous range of sound intensity, from about 10⁻¹² W/m² at the threshold of hearing to 1 W/m² at the threshold of pain: a factor of a trillion. A logarithmic scale compresses this into 0 to 120 decibels. Our perception of loudness is also roughly logarithmic, so the scale fits.
Power quantities: 10 log
For quantities proportional to power or energy (power, intensity, energy density):
L = 10 log₁₀(P / P₀) dB.
- +3 dB doubles the power,
- +10 dB multiplies it by 10,
- +20 dB by 100.
Amplitude quantities: 20 log
Sound pressure, voltage and field strength are amplitudes; power is proportional to their square. So:
L = 20 log₁₀(A / A₀) dB.
- +6 dB doubles the amplitude,
- +20 dB multiplies it by 10.
Both formulas give the same decibel value for the same physical change. That is the point of the definitions.
Adding sound levels
Sound from independent sources adds by energy. Convert each level to energy, add, and convert back:
L_total = 10 log₁₀ (10^(L₁/10) + 10^(L₂/10) + ...).
Rules of thumb:
| Difference between two levels | Add to the higher |
|---|---|
| 0 dB | 3 dB |
| 1 dB | 2.5 dB |
| 3 dB | 1.8 dB |
| 6 dB | 1.0 dB |
| 10 dB | 0.4 dB |
Ten equal sources are 10 dB louder than one. Three machines at 85, 88 and 90 dB make 92.9 dB together.
Averaging
To average levels over time or space, average the energies, not the decibel numbers. The energy average of 80 dB and 90 dB is 87.4 dB, not 85 dB. Loud periods dominate, which is why workplace noise exposure (L_Aeq) and environmental noise limits are energy averages.
Subtracting background noise
When measuring a machine in a noisy place, measure the total and the background separately. The machine alone is 10 log₁₀(10^(L_t/10) − 10^(L_b/10)). If the difference is less than 3 dB, the measurement is unreliable.
Common references
| Unit | Reference |
|---|---|
| dB SPL | 20 µPa sound pressure |
| dB re 1 pW | sound power |
| dB re 1 pW/m² | sound intensity |
| dBm | 1 milliwatt |
| dBW | 1 watt |
| dBV | 1 volt |
| dBu | 0.7746 volt |
A decibel without a reference is only a ratio. Always state the reference.
From sound power to sound pressure
Sound power is a property of the source; sound pressure depends on where you are. In free space, a point source with sound power level L_W gives L_p = L_W − 20 log₁₀ r − 11 dB at distance r metres. Doubling the distance lowers the level by 6 dB. On a hard floor, add 3 dB.
Using the calculator
- Enter a decibel value to see power and amplitude ratios.
- List levels to add and average them.
- Enter background noise to subtract it.
- Enter source power and distance for sound power and pressure levels.
- Enter voltage and pressure for dBV, dBu and SPL.
A-weighting
Sound level meters usually apply A-weighting, which reduces low and very high frequencies to match human hearing. dB(A) and dB(C) values should not be mixed.
Limits
The calculator assumes incoherent sources and free-field spreading. Rooms add reflections that raise levels. Official noise assessments need calibrated instruments and the relevant standards.