Confined Space Entry Permits: What They Must Contain
Why confined spaces are so dangerous, what an entry permit must include under OSHA 1910.146, safe atmosphere limits and the roles of everyone involved.

Confined Space Entry Permits: What They Must Contain
Confined spaces such as tanks, sewers, pits, silos, vaults, manholes and vessels kill workers every year, and too often the victims include colleagues who rush in to help. The hazards are often invisible: missing oxygen, toxic gas or a flammable atmosphere. That is why entry into a permit-required confined space is controlled by a written permit. The Confined Space Entry Permit Generator produces one with the required contents. This guide explains them.
What makes a space dangerous
A confined space is large enough to enter, has limited means of entry or exit and is not designed for continuous occupancy. It becomes permit-required when it has, or could have, serious hazards:
- Oxygen deficiency: from rusting steel, microbial activity or displacement by other gases. Below about 16 % oxygen, judgement fails; below 10 %, unconsciousness comes within seconds.
- Toxic gases: hydrogen sulphide in sewers and wells, carbon monoxide from engines or combustion, solvent vapours.
- Flammable atmospheres: methane, solvent vapours and fuel gases.
- Engulfment: grain, sand, sludge or liquid flowing in.
- Other hazards: moving machinery, heat, falls and difficult rescue.
The permit's contents
OSHA 29 CFR 1910.146(f) lists what an entry permit must include:
- The space to be entered.
- The purpose of the entry.
- The date and authorised duration.
- The authorised entrants.
- The attendants.
- The entry supervisor, with the signature authorising entry.
- The hazards of the space.
- The measures to isolate the space and eliminate or control hazards: lockout and tagout of energy, blanking and bleeding of lines, purging, ventilation.
- The acceptable entry conditions.
- The results of initial and periodic tests, with the tester's name and the time.
- The rescue and emergency services and how to summon them.
- The communication method between entrants and attendants.
- The equipment provided: PPE, testing and monitoring, communication, alarms, rescue equipment.
- Other information needed for safety, and other permits, such as hot work.
The UK Confined Spaces Regulations 1997 and their approved code of practice set out a similar safe system of work.
Acceptable atmosphere
OSHA defines a hazardous atmosphere as including:
- Oxygen below 19.5 % or above 23.5 %.
- Flammable gas at 10 % or more of its lower explosive limit (LEL).
- Toxic substances above their permissible exposure limits.
Many employers set alarm levels such as 10 ppm for hydrogen sulphide and 25-35 ppm for carbon monoxide. Test with a calibrated, bump-tested multi-gas detector in the order oxygen, flammables, then toxics, and at several heights, because gases layer: hydrogen sulphide is heavier than air, methane lighter. Continue monitoring throughout the entry.
The roles
- Entry supervisor: confirms everything on the permit is in place, authorises entry, can terminate it, and cancels the permit when the job is finished or conditions change.
- Authorised entrants: know the hazards and signs of exposure, use the equipment, stay in contact and leave immediately when told or when alarms sound.
- Attendant: stays outside for the whole entry, keeps count of entrants, watches conditions and communicates with entrants. The attendant never enters to rescue: they summon help and use non-entry retrieval, such as a winch on a tripod.
Rescue
Rescue must be planned before entry. Calling the public emergency service may be too slow for spaces where oxygen is missing; many sites need a trained rescue team on standby with retrieval equipment. Rescue teams should practise in representative spaces at least once a year.
After the work
Cancel the permit, note any problems encountered and keep it. OSHA requires cancelled permits to be kept for at least a year and reviewed to improve the programme.
Summary
A confined space permit records the space, purpose, duration, people, hazards, isolation, gas tests, rescue, communication and equipment, and it is only valid while conditions remain acceptable. Prepare yours with the confined space entry permit generator, and never let anyone enter until every item is in place.