How to Design a Battery Pack: Series, Parallel and the S-P Layout

How to Design a Battery Pack: Series, Parallel and the S-P Layout

Whether it powers an e-bike, a camping power station or a robot, a battery pack is a grid of identical cells. How you arrange that grid decides the voltage, the capacity, the current the pack can deliver and how much it weighs. This guide explains the arithmetic and the practical checks, and shows how to try layouts quickly with the free battery series and parallel pack designer.

Series raises voltage, parallel raises capacity

Join cells end to end, positive to negative, and their voltages add while the capacity stays that of one cell. Join cells side by side, all positives together and all negatives together, and the voltage stays the same while capacities and current ratings add. A pack is described by both counts: 13S4P means 13 groups in series, each group being 4 cells in parallel, 52 cells in all.

For 18650 cells of 3.6 V and 3.0 Ah, 13S gives 46.8 V nominal and 4P gives 12 Ah. Energy is voltage times capacity: 561.6 Wh.

Start from what you need

Most projects begin with a target. A controller or inverter fixes the voltage, the range or runtime fixes the energy and the motor fixes the current. In the Reach a target tab, enter all three. The designer rounds the series count to the nearest whole cell at nominal voltage, then raises the parallel count until both capacity and current are met. A table of nearby parallel counts shows how energy and mass grow with each extra cell per group, so you can trade range against weight.

Check the voltage range, not just the nominal

A lithium-ion cell swings from about 4.2 V full to about 2.5-3.0 V empty, so a 13S pack runs from 54.6 V down to around 32.5 V. Your controller, inverter or charger must accept the full range. LiFePO4 cells sit between 3.65 V and 2.5 V, with a flat curve around 3.2 V, which is why four in series make a convenient 12.8 V battery.

Current, resistance and heat

The pack's maximum continuous current is the cell rating times the parallel count. Pack internal resistance is the cell resistance times S, divided by P. At full current this resistance causes a voltage drop and heat. With 18 mΩ cells, a 13S4P pack has 58.5 mΩ, so at 60 A it sags about 3.5 V and turns roughly 210 W into heat. If that is too much, add parallel cells or choose cells with lower resistance. The designer warns when the C-rate passes 3C.

Balance leads and the BMS

Lithium cells must never be overcharged or over-discharged individually, so a battery management system watches every series group. It needs a sense wire at each junction between groups and at both ends: S + 1 wires. A 13S pack needs 14, and the BMS itself must be a 13S model. The layout drawing labels the taps B0 to B13 so you can check the wiring order before soldering.

Weight and energy density

Cell mass times cell count gives the bare weight. Nickel strip, the BMS, wiring, insulation and a case add more; the designer uses an editable allowance of 15 %. The result in watt-hours per kilogram is a quick way to compare cells: 21700 cells usually beat 18650 cells, and lead-acid sits far below lithium.

Rules worth knowing

Packs above 100 Wh have limits on aircraft under IATA guidance, and above about 60 V DC stricter electrical safety rules usually apply. The designer points these out when your design crosses them.

Try it with the presets

Presets include common 18650 and 21700 Li-ion cells, LiFePO4 cylindrical and prismatic cells, lead-acid blocks and 2 V cells, and NiMH AA cells. Every field can be edited to match your exact cell datasheet. Save design keeps a list of options to compare, and Print gives the figures with the layout drawing.

Practise the arithmetic

The Practice tab asks for the voltage, capacity and energy of random S-P layouts, a quick way to make the rules automatic.

Limits

Datasheet figures are measured under ideal conditions; real capacity drops at high current and low temperature, and cells from different batches differ. Never mix cells of different models, capacities or ages. The designer does not cover spot welding, fusing, cooling or certification. Lithium packs can burn violently when built or charged badly, so get proper training and use a suitable BMS and charger.