RMS vs Average vs Peak: Understanding AC Waveforms
What RMS really means, how to convert peak to RMS for sine, square, triangle and PWM waves, why cheap meters misread them, and how to calculate power.

RMS vs Average vs Peak: Understanding AC Waveforms
UK and European mains is 230 V, but an oscilloscope shows the voltage swinging up to about 325 V and down to −325 V. Both are correct. They describe the same waveform in different ways: one is the RMS value, the other the peak. The free AC Waveform RMS and Average Calculator converts between RMS, average and peak for common waveforms and calculates the power they deliver.
What RMS means
RMS stands for root mean square: square the waveform, take the average, then the square root. The result is the steady DC voltage that would heat a resistor by the same amount. That is why mains voltage, amplifier power and heater ratings use RMS: it tells you how much work the waveform does.
Converting peak to RMS
The ratio depends on the waveform's shape:
- Sine: RMS = peak ÷ √2 ≈ 0.707 × peak. 325 V peak is 230 V RMS.
- Square (switching between +peak and −peak): RMS = peak.
- Triangle and sawtooth: RMS = peak ÷ √3 ≈ 0.577 × peak.
- Half-wave rectified sine: RMS = peak ÷ 2.
- PWM (switching between 0 and peak with duty cycle D): RMS = peak × √D, average = peak × D.
Average versus RMS
The average of a symmetrical AC waveform is zero, so "average" usually means the rectified average, the average of the absolute value. For a sine wave it is 0.637 × peak. The ratio of RMS to rectified average is the form factor: 1.111 for a sine.
Why meters disagree
Inexpensive multimeters measure the rectified average and multiply by 1.111, which gives the right RMS only for pure sine waves. On a square wave they read 11% high; on a triangle about 4% low; on the distorted waveforms from dimmers, inverters and switch-mode power supplies they can be far off. True-RMS meters calculate the real value and are worth having for anything other than clean mains.
Crest factor
The crest factor is peak ÷ RMS: 1.414 for a sine, 1 for a square wave, much higher for spiky waveforms like the current drawn by a phone charger. Amplifiers, converters and meters specify the highest crest factor they handle accurately.
DC offset and PWM
When a waveform has a DC offset, the total RMS combines both parts: √(DC² + AC RMS²). With PWM, the average voltage is what a motor's speed or a filtered output follows, while the RMS sets the heating in resistors, LEDs and motor windings. A 10 V PWM signal at 25% duty averages 2.5 V but has an RMS of 5 V.
Power
Power into a resistor is RMS voltage squared divided by resistance. 230 V RMS across 100 Ω dissipates 529 W. Always use RMS, never peak, when sizing resistors, fuses and cables.
A worked example
A 12 V LED strip driven by PWM at 25% duty looks a quarter as bright as at full power, because brightness follows the average current. But the RMS voltage is half the supply, 6 V, so a series resistor heats as if it carried half the current continuously, not a quarter. Sizing resistors from the average would underestimate their heat by a factor of four.
Measuring correctly
To measure non-sinusoidal waveforms, use a true-RMS meter or an oscilloscope's RMS measurement over a whole number of cycles. Check the meter's bandwidth too: a meter rated for 50 Hz may not respond correctly to a 20 kHz PWM signal.
Step by step
- Choose the waveform.
- Enter the peak voltage and, for PWM, the duty cycle.
- Add any DC offset.
- Enter the load resistance.
- Read RMS, averages, factors and power, and check the plot.
Mains voltages are dangerous; only measure them with suitable equipment and training. The calculator runs in your browser.