8D Problem Solving Report Builder
Work through the eight disciplines in order: report details, team, problem description, containment, root cause with escape point and verification, permanent corrective actions with owners and dates, prevention and closure, then print a customer-ready 8D report or download it as Word.
Runs in your browser. Your files never leave your device. See how to check
…
How to do it
- 1D0
Enter the 8D number, customer, part and status.
- 2D1-D2
Name the team and describe the problem.
- 3D3-D4
Record containment and both root causes.
- 4D5-D7
List corrective and preventive actions.
- 5D8
Close, check warnings and print the report.
About this tool
The 8D Problem Solving Report Builder is a form-and-preview editor for the eight disciplines report that automotive, aerospace and general manufacturing customers ask a supplier to return after a quality complaint. Each discipline is a folding section. D0 Report details holds the 8D number, customer, part or product, the customer's complaint reference, the date opened and a status picked from Open, Containment done, Root cause found, Corrective action in place and Closed; the status is printed in bold in the report heading. D1 Team is a table of names and roles. D2 Problem description is a free-text box intended for an is / is-not and 5W2H description, with a separate number box for the quantity affected. D3 Containment lists the interim actions, one per line, and the date they were in place, which is shown in the D3 heading. D4 Root cause has three separate boxes: the cause of occurrence, why the defect escaped detection, and how the cause was verified. D5 and D6 share a table of permanent corrective actions with columns for the action, owner, due date and an implemented or verified note. D7 Prevention lists the system changes that stop recurrence on similar parts and processes, and D8 Closure holds a team recognition note and a closing date, followed by signature lines for the 8D team leader, the quality manager and the customer if required. When the closing date is empty, the report says the 8D is still open. Three checks look for the gaps that customers most often send a report back for: an empty escape cause, no evidence of how the root cause was verified, and a status of Closed while some corrective actions have no implemented note.
Who this is for
Supplier quality engineers answering a customer complaint, production and quality managers who chair 8D teams, auditors checking that corrective action records are complete, and students learning structured problem solving for IATF 16949 or AS9100 work.
How to use it
1. Fill in D0 with the 8D number, customer, part, complaint reference, opening date and status. 2. Name the team in D1 and describe the problem in D2 with the quantity affected. 3. Record containment in D3 and both root causes with their verification in D4. 4. List the corrective actions with owners and dates, then the prevention steps. 5. Add the closure note, check the warnings and print or download the report.
What the sample shows
The sample is report 8D-2026-014 for Example Motors plc, complaint reference QN-55821, opened on November 2, 2026, for steering bracket R, part 1103. The customer found 3 brackets with hole B 0.4 mm out of position against a ±0.2 mm tolerance in lot 2026-43, all from press 2 on the night shift. Containment on November 3 sorted 2,140 parts at the plant and at the customer and found 9 more rejects. The occurrence cause is a locating pin in the press 2 die worn by 0.35 mm and missing from the die maintenance plan; the escape cause is a final inspection that checked hole size but not position. Verification came from 50 parts made with a new pin, all within ±0.08 mm. Of the three corrective actions, the hardened pin is marked done and verified on 2026-11-05, while the pin wear check and the hourly control plan check are still waiting. The status reads Root cause found and the report prints as open because no closing date has been entered.
Saving, versions and downloads
The report is saved automatically in this browser. Save version keeps a dated snapshot, which is useful because an 8D is usually sent to the customer several times as it moves from containment to closure. Print / PDF, Word (.doc) and Web page (.html) export the same page you see in the preview.
Limits
There is one template, the customer complaint layout, and D5 and D6 are combined in a single table rather than separate selection and implementation sections. The quantity, dates and status are typed in and are not linked to each other, so the report will not stop you closing an 8D whose dates are in the future. Customer portals with their own 8D forms may need the text copied across. This builder records an investigation; it is not engineering or quality management advice, and the correctness of the root cause rests on your team's data and verification.
Worked example
8D-2026-014: 3 brackets out of position, 2,140 parts sorted with 9 rejects, worn locating pin as the occurrence cause, 1 of 3 actions verified.
Quick facts
- Category: Business & Work
- Works in your browser, no sign-up, no upload.
- Your input stays on your device.
- Available in English.
- Content last reviewed:
- Official source: Ford 8D (Eight Disciplines) problem solving method; VDA and AIAG 8D guidance
Frequently asked questions
What are the eight disciplines?
D0 plan and report details, D1 team, D2 problem description, D3 containment, D4 root cause, D5 choose and D6 implement permanent corrective actions, D7 prevent recurrence and D8 recognise the team and close.
Why does D4 ask for two root causes?
One explains why the defect was made and the other why it was not caught before reaching the customer. Most customers reject an 8D that fixes only the cause of occurrence.
What counts as verifying the root cause?
Evidence that switching the cause on and off changes the result, such as parts measured after the fix, a trial or a test. Write what was done and the result in the verification box.
Can I mark the 8D as Closed while actions are open?
You can select it, but a warning appears if any corrective action row has an empty Implemented / verified note. Fill that column in before sending a closed report.
Can the customer sign the report?
The D8 section ends with signature rows for the 8D team leader, the quality manager and the customer if required. They print blank so they can be signed on paper.
How do I send updates as the 8D progresses?
Save a version before each submission, change the status and fill in the next disciplines. Each saved version can be printed again later to show what the customer received.
