Dose-Response IC50 and EC50 Calculator
Paste concentrations with replicate responses for one or more compounds, fit four-parameter logistic curves on a log scale, read IC50 or EC50 with 95% confidence intervals, Hill slope, top, bottom and R², compare potency between compounds and download the graph and table.
Działa w Twojej przeglądarce. Twoje pliki nigdy nie opuszczają urządzenia. Zobacz, jak to sprawdzić
…
Jak to zrobić
- 1Choose units
And IC50 or EC50.
- 2Paste data
Concentration plus replicates.
- 3Add curves
One per compound.
- 4Read results
IC50, CI, Hill slope.
- 5Export
Graph and CSV.
O tym narzędziu
The half-maximal inhibitory concentration, IC50, and its activating counterpart, EC50, are the most common way to describe how potent a drug, toxin or inhibitor is. They are found by fitting a sigmoidal curve to responses measured over a range of concentrations. This calculator fits the standard four-parameter logistic model on log10 concentration, the same approach used in assay development guides. Paste one row per concentration with any number of replicate responses, usually normalised to percent of control. Add more curves to compare compounds, cell lines or conditions on one graph, each in its own colour, with dashed lines marking each IC50.
Who this is for
Pharmacology and biology students analysing a cell viability or enzyme inhibition assay, researchers screening compounds, toxicologists estimating effective concentrations and anyone who needs an IC50 with a confidence interval rather than a value read off a graph by eye.
Entering data
Each row starts with the concentration, followed by replicate responses separated by tabs, commas or spaces, so you can paste straight from a plate reader spreadsheet. Concentrations must be above zero because the model works on a log scale; handle vehicle controls in your normalisation. Choose the concentration unit and whether to report IC50 or EC50.
The model
Response = Bottom + (Top − Bottom) / (1 + 10^((logIC50 − log concentration) × Hill slope)). The four parameters are the lower plateau, the upper plateau, the logIC50 and the Hill slope. Inhibition curves have a negative slope in this form, activation curves a positive one.
Constraints
If your data does not reach a plateau at one end, the fit can wander. Constrain the top to 100 and the bottom to 0 when the data is normalised to controls; this gives an absolute IC50 and steadier estimates.
Confidence intervals
The 95 percent interval comes from the standard error of logIC50 and Student's t, then is converted back to concentration, so it is asymmetric on the linear scale. Non-overlapping intervals between compounds suggest a real potency difference, and the ratio of IC50 values is shown.
Export
Download the graph as SVG or a high-resolution PNG and the results table as CSV, including logIC50, Hill slope, plateaus, R² and the number of points.
Tips
- Use 8 to 12 concentrations spaced evenly on a log scale. - Make sure the range covers both plateaus. - Run at least three replicates per concentration.
Common mistakes
- Entering zero concentration as a data point. - Comparing IC50 values from assays with different incubation times.
Limits
The tool fits each curve separately; it does not test whether curves share parameters. Results describe your assay, not clinical potency. Not for diagnostic or regulatory use.
Przykład z rozwiązaniem
With the sample data, Compound A has IC50 = 4.49 µM (95% CI 3.94 to 5.11) and Hill slope −1.06; Compound B has IC50 = 15.68 µM (14.13 to 17.39), so B is 3.49 times less potent than A.
W skrócie
- Kategoria: Matematyka i nauka
- Działa w przeglądarce, bez rejestracji i wysyłania.
- Wpisane informacje zostają na Twoim urządzeniu.
- Dostępne po angielsku.
- Treść ostatnio sprawdzona:
- Oficjalne źródło: NCBI Assay Guidance Manual: assay operations and dose–response curve fitting
Najczęstsze pytania
What model is used?
The four-parameter logistic on log10 concentration: bottom, top, logIC50 and Hill slope.
Can I enter replicates?
Yes. Put each replicate in its own column after the concentration.
Does it give a confidence interval?
Yes, a 95% interval from the standard error of logIC50.
Can I compare compounds?
Yes. Add curves and they are fitted and plotted together with a potency ratio.
What about EC50?
Switch the report to EC50 for activation curves; the fit is the same.
Should I constrain top and bottom?
When data is normalised to controls, constraining to 100 and 0 often gives steadier fits.