CAPE and CIN Sounding Calculator
Enter or paste a sounding (pressure, height, temperature, dew point) and the calculator lifts a surface parcel to get CAPE, CIN and the key levels.
Berjalan dalam pelayar anda. Fail anda tidak pernah meninggalkan peranti. Lihat cara menyemaknya
…
Cara melakukannya
- 1Enter the surface row
Pressure, height, temperature, dew point.
- 2Add upper levels
One row per level.
- 3Check the order
Surface first, highest last.
- 4Read CAPE and CIN
With LCL, LFC, EL and lifted index.
Tentang alat ini
Convective Available Potential Energy (CAPE) measures how much energy a rising air parcel can gain from buoyancy, and it is the main ingredient forecasters check before thunderstorms. Convective inhibition (CIN) is the energy needed to lift the parcel to its level of free convection. This calculator lifts a surface parcel through your sounding: dry adiabatically to the lifting condensation level, then along a moist pseudo-adiabat, and integrates the buoyancy using virtual temperature, as recommended by Doswell and Rasmussen.
Who this is for
Meteorology students, storm chasers, glider pilots and forecasters checking a sounding from a radiosonde, a model or a textbook exercise.
Entering the sounding
Each row needs pressure (hPa), height (m), temperature (°C) and dew point (°C), from the surface upward. Add rows as needed; more levels give a better result. The first row is used as the surface parcel.
How the parcel is lifted
1. From the surface to the LCL, the parcel follows a dry adiabat (constant potential temperature) and keeps its mixing ratio. 2. Above the LCL it follows a pseudo-adiabat, integrated in 5 hPa steps with the moist lapse rate. 3. At each level the buoyancy (Tv,parcel − Tv,env)/Tv,env is computed with virtual temperatures, and g × buoyancy × Δz is summed.
The outputs
- **CAPE**: positive area between the LFC and the equilibrium level. - **CIN**: negative area below the LFC. - **LCL**: where the parcel saturates. - **LFC**: where the parcel first becomes warmer than its environment above the LCL. - **EL**: where it becomes cooler again (approximate thunderstorm top). - **Lifted index**: environment minus parcel temperature at 500 hPa; negative values mean instability.
Interpreting CAPE
Below 300 J/kg is weak, 300–1000 marginal, 1000–2500 moderate, 2500–4000 strong and above 4000 extreme. CAPE alone does not make storms: you also need lift to overcome CIN and, for severe storms, wind shear.
Good practice
Use a sounding from the time and place of interest; surface heating during the day can change CAPE a lot. Mixed-layer or most-unstable parcels, used by many forecast centres, give different values.
Where to find soundings
Radiosonde soundings are launched twice a day at 00 and 12 UTC at hundreds of stations, and university and government websites publish them as text tables that can be pasted here. Forecast models also provide point soundings for any time, which help to judge how afternoon heating will change the values.
Text formats differ, so check the column order before pasting.
Worked example
The sample warm-season sounding (28 °C and 21 °C dew point at 1000 hPa) gives an LCL near 903 hPa, an LFC near 815 hPa, CAPE of about 2,070 J/kg (moderate), CIN about −50 J/kg and a lifted index of −5.6.
Limits
Surface-based parcel only, no entrainment or ice processes; values differ slightly from professional software.
Contoh berselesaian
The sample sounding gives about 2,070 J/kg of CAPE and a lifted index of −5.6.
Ringkasnya
- Kategori: Matematik & sains
- Berjalan dalam pelayar, tanpa pendaftaran, tanpa muat naik.
- Maklumat yang anda masukkan kekal pada peranti anda.
- Tersedia dalam bahasa Inggeris.
- Kandungan disemak kali terakhir:
- Sumber rasmi: Parcel theory as in Bolton (1980) for the LCL and a pseudo-adiabatic lapse rate integrated in pressure; CAPE and CIN from the virtual-temperature buoyancy integral (Doswell and Rasmussen 1994); lifted index at 500 hPa (Galway 1956)
Soalan lazim
What is CAPE?
The buoyant energy available to a rising air parcel, in J/kg.
What CAPE value means thunderstorms?
Above about 1000 J/kg is moderate instability, if there is lift.
What is CIN?
The energy needed to lift a parcel to its level of free convection.
Why use virtual temperature?
Moist air is lighter; ignoring it underestimates CAPE.
What is the lifted index?
Environment minus parcel temperature at 500 hPa.
Is my data stored?
No. Everything is calculated in your browser.
