Confined Space Entry Permit
Fill in the space, purpose, duration, entrants, attendants and entry supervisor, hazards and isolation measures, atmospheric test readings, rescue arrangements and equipment, and get a permit that checks the gas readings against acceptable limits.
ブラウザ内で動作します。ファイルは端末の外に出ません。 確認方法を見る
…
使い方
- 1Describe the space and work
Purpose and duration.
- 2Name the people
Entrants, attendants, supervisor.
- 3List hazards and isolation
Lockout, ventilation.
- 4Enter gas readings
O2, LEL, H2S, CO.
- 5Add rescue and equipment
Then print and sign.
このツールについて
Tanks, sewers, pits, silos, vaults and vessels can kill quickly: oxygen can be missing, toxic or flammable gas can build up, and people can be engulfed or trapped. Many of those who die in confined spaces are would-be rescuers. That is why entry into a permit-required confined space is controlled by a written permit, issued by an entry supervisor after hazards are isolated and the atmosphere tested. This generator creates a permit with the contents OSHA 1910.146(f) requires and checks the gas readings against the acceptable entry limits, flagging any that fail.
Who this is for
Entry supervisors, safety officers, utility and water companies, maintenance contractors, tank cleaners and training providers.
What a permit must contain
OSHA 1910.146(f) requires the space, the purpose of entry, the date and authorised duration, the authorised entrants, the attendants, the entry supervisor, the hazards, the measures used to isolate the space and eliminate or control hazards (lockout, purging, ventilation), the acceptable entry conditions, test results with the tester's identity and time, the rescue and emergency services and how to summon them, the communication method, the equipment provided, and any other permits such as hot work.
Acceptable atmosphere
| Test | Acceptable | |---|---| | Oxygen | 19.5-23.5 % | | Flammable gas | below 10 % LEL | | Hydrogen sulphide | below 10 ppm (typical alarm level) | | Carbon monoxide | below 25 ppm (typical alarm level) | Test in the order oxygen, then flammables, then toxics, at several levels in the space, because gases layer. Monitor continuously during entry.
Before entry
Isolate energy and process lines (lock and tag), drain and purge, ventilate with forced air, test the atmosphere with a calibrated, bump-tested detector, set up rescue equipment such as a tripod and winch, and confirm the attendant and communication arrangements.
During and after entry
The attendant stays outside, keeps count of entrants and never enters to rescue. The supervisor cancels the permit when the work is done or if conditions change. OSHA requires cancelled permits to be kept for at least one year for review.
Roles
The **entry supervisor** checks that the permit conditions are met, signs the permit, terminates entry if conditions change and cancels the permit at the end. **Authorised entrants** know the hazards, use the equipment and leave immediately when told or when an alarm sounds. The **attendant** remains outside for the whole entry, keeps an accurate count of entrants, monitors conditions, communicates with entrants and summons rescue without entering. Everyone needs training for their role before the first entry, and rescue teams should practise retrievals from representative spaces at least once a year.
Common mistakes
- Testing only at the opening. - Relying on ventilation without continuous monitoring. - Planning rescue as "call the fire service" for spaces where minutes count. - Letting the attendant enter to help.
Limits
A permit template; it does not replace your confined space programme, training or competent supervision. This is not professional advice.
計算例
Wet well entry 08:00-12:00: O2 20.8 %, LEL 0, H2S 1 ppm, CO 2 ppm, all acceptable.
ポイント
- カテゴリ: ドキュメント
- ブラウザ内で動作し、登録もアップロードも不要です。
- 入力した情報は端末内にとどまります。
- 英語で利用できます。
- 内容の最終確認日:
- 公式情報源: Entry permit contents in OSHA 29 CFR 1910.146(f) (permit-required confined spaces), acceptable entry conditions in 1910.146(b): oxygen 19.5-23.5 %, flammable gas below 10 % of the lower explosive limit; UK Confined Spaces Regulations 1997 and HSE L101 Safe work in confined spaces
よくある質問
What must a confined space permit include?
Space, purpose, duration, people, hazards, isolation, tests, rescue, communication and equipment.
What oxygen level is acceptable?
Between 19.5 % and 23.5 %.
What flammable gas level is acceptable?
Below 10 % of the lower explosive limit.
Can the attendant enter to rescue?
No: attendants summon rescue and use non-entry retrieval.
How long are permits kept?
At least one year under OSHA.
Is my data stored?
Permit entries are filled into the document only.