Vision Check Suite
Calibrate your screen with a bank card, then check distance and near acuity, colour vision, contrast and the Amsler grid, scored and saved per eye.
Funziona nel tuo browser. I tuoi file non lasciano mai il dispositivo. Scopri come verificarlo
…
Come si usa
- 1Calibrate
Match the on-screen box to a bank card and set your viewing distances.
- 2Choose an eye
Cover one eye, wear your usual glasses, and pick right, left or both.
- 3Distance test
Stand at the set distance and tap the letters or E directions you see.
- 4Near test
Hold the screen at reading distance and repeat with smaller letters.
- 5Colour and contrast
Read the dot plates, order the hues and identify fading letters.
- 6Track
Use the Amsler grid, then review and download your results history.
Informazioni su questo strumento
Eye problems often creep up slowly, and many people only notice when they struggle to read a road sign or a menu. A quick home check between eye examinations can show whether one eye has become weaker, whether your near vision has changed or whether something needs a professional look sooner. This suite brings the standard screening tests together and makes them accurate on your own screen. It starts with calibration: hold any standard bank or ID card against the screen and drag until the box matches it, so the tool knows exactly how many pixels make a millimetre. You then choose your viewing distance, such as 3 metres for distance vision and 40 centimetres for near vision, and every letter is drawn at the correct physical size for that distance. The acuity test uses logMAR lines of five Sloan letters, the design used on modern clinical charts, or a tumbling E for children and people who do not read the Latin alphabet. You tap the letter or direction you see, and the test steps down a line at a time until you make three mistakes on a line. It is scored letter by letter, and the result is shown as logMAR, a Snellen fraction such as 6/6 or 20/20, a decimal value and, for near vision, an approximate N print size. The colour section shows generated dot plates with numbers hidden along red-green and blue-yellow confusion lines plus a hue-ordering task. The contrast test shows letters that fade in 0.15 log-unit steps. The Amsler grid lets you tap any squares that look wavy or missing. Every result is saved with the date and the eye tested, so you can track changes over time.
Who this is for
Adults who want to keep an eye on their vision between eye tests, parents who want to check a child's distance vision, people monitoring an existing condition between appointments as their clinician advises, and drivers who want a rough idea of whether they meet a typical standard.
Reading your acuity result
| logMAR | Snellen (metres) | Snellen (feet) | What it usually means | |---|---|---|---| | −0.1 | 6/4.8 | 20/16 | Better than average | | 0.0 | 6/6 | 20/20 | Typical adult vision | | 0.3 | 6/12 | 20/40 | Common minimum for driving in many countries | | 0.5 | 6/19 | 20/63 | Moderately reduced | | 1.0 | 6/60 | 20/200 | Severely reduced |
Getting an accurate result
Calibrate carefully, measure the viewing distance with a tape, use full screen brightness in a well-lit room, wear your usual glasses or contact lenses and cover one eye with your palm without pressing. Test each eye separately. A small phone screen cannot show the largest letters at 3 m, and a low-resolution screen may not show the smallest lines; the calibration page tells you the limits.
Colour and contrast
Colour vision differences are common, affecting about 1 in 12 men and 1 in 200 women of Northern European descent, usually in the red-green range. The generated plates and hue task can suggest a difference but cannot classify it, because screens are not colour calibrated. Contrast sensitivity, the ability to see faint shapes, can fall with cataract and other conditions even when the letter chart is normal.
Worked example
Testing the right eye at 3 m, a person reads all five letters on the logMAR 0.3 and 0.2 lines and two letters on the 0.1 line before making three mistakes. The score is 0.3 + 0.1 − 12 × 0.02 = 0.16 logMAR, about 6/8.7 or 20/29. The left eye scores 0.00 (6/6), so the right eye is slightly weaker, which is worth mentioning at the next eye test.
Limits
This is a home screening aid, not a diagnosis and not a substitute for an examination by an optometrist or ophthalmologist, which also checks eye health and pressure. Results depend on your screen, lighting and distance. Seek urgent care for sudden loss of vision, new distortion, flashes, a shower of floaters or a painful red eye. Results stay in this browser.
Esempio svolto
Right eye at 3 m: lines 0.3 and 0.2 complete, 2 letters at 0.1 → 0.16 logMAR (about 6/8.7, 20/29).
In breve
- Categoria: Salute e fitness
- Funziona nel browser, senza registrazione né caricamento.
- Le informazioni che inserisci restano sul tuo dispositivo.
- Disponibile in inglese.
- Contenuto rivisto l'ultima volta il:
- Fonte ufficiale: ISO 8596 / logMAR letter chart design (Bailey-Lovie, ETDRS principles); Pelli-Robson contrast scoring; Amsler grid
Domande frequenti
How accurate is a screen eye test?
With careful calibration and a measured distance, letter sizes are correct, so acuity results are a reasonable screening estimate. Clinical tests control lighting and contrast more precisely, so treat results as a guide.
Why do I need a bank card?
Screens have different pixel densities. Matching a standard card, which is 85.6 mm wide, lets the tool draw letters at exactly the right physical size.
What distance should I use?
Three metres or more for distance vision, and 40 cm for near vision. Shorter distances work if your screen is small, but letters at the bottom of the chart may become too small to draw.
Can it diagnose colour blindness?
No. The plates are generated for screening on uncalibrated screens. An optometrist can confirm and classify a colour vision difference with calibrated tests.
What is the Amsler grid for?
It helps detect distortion in central vision, which can be a sign of macular problems. New or changing distortion needs a prompt professional check.
Are my results private?
Yes. Calibration and results are saved only in this browser.