Battery Series and Parallel Pack Designer
Pick a cell, set how many go in series and in parallel, and see pack voltage, capacity, energy, current, weight, BMS balance leads and the wiring layout.
S'exécute dans votre navigateur. Vos fichiers ne quittent jamais votre appareil. Voir comment vérifier
…
Comment faire
- 1Pick a cell
Choose a preset or type your cell's voltage, capacity, current, mass and resistance from its datasheet.
- 2Set S and P
Use the steppers to set cells in series and in parallel, and the mass overhead.
- 3Read the pack figures
Check voltage range, Ah, Wh, current, power, mass and balance wires.
- 4Check the layout
Study the drawing of parallel groups, series links and balance taps.
- 5Work from a target
In Reach a target enter the voltage, capacity and current you need and use the suggested layout.
- 6Save and print
Save the design, export CSV or print the working with the drawing.
À propos de cet outil
E-bikes, power walls, robots, torches and solar boxes all use the same trick: many small cells joined in series to raise the voltage and in parallel to raise the capacity. This designer works out what a given arrangement gives you. Choose a cell preset (18650 and 21700 Li-ion, LiFePO4 cylinders and prismatic cells, lead-acid blocks and cells, NiMH AA) or edit every value: nominal, full and empty voltage, capacity, maximum current, mass and internal resistance. Set the series count S and the parallel count P with the steppers, or enter a target voltage, capacity and current and let the tool suggest the layout. You get pack voltage range, Ah, Wh, maximum continuous current and power, cell count, estimated mass with an allowance for strip, BMS and case, energy per kilogram, the number of balance wires and the voltage sag at full current. A drawing shows the cell grid, series links and balance taps.
Series and parallel in one sentence
Cells in series add their voltages and keep the capacity of one cell; cells in parallel keep the voltage and add their capacities and currents. A pack written 13S4P has 13 groups in series, each made of 4 cells in parallel, 52 cells in total.
What the numbers mean
Nominal voltage is the average during discharge and the figure used for energy. Full and empty voltages show the range a controller or inverter must accept; a 13S Li-ion pack swings from 54.6 V full to about 32.5 V empty. Energy in watt-hours is nominal voltage times capacity. Maximum continuous current is the cell rating times P. Pack internal resistance is S × cell resistance ÷ P, which gives the voltage sag and the heat at full load.
Balance leads and the BMS
Lithium packs need a battery management system that watches every series group. It needs a sense wire at each junction plus both ends, so a pack with S groups has S + 1 balance leads. Lead-acid and NiMH packs are usually charged as a whole, so no balance count is given for them.
Reaching a target
On the Reach a target tab, enter the voltage, capacity and current you need. S is rounded to the nearest whole number of cells at nominal voltage and P is raised until both capacity and current are met. A table of nearby P values shows how mass and energy grow, so you can trade range against weight.
Worked example
Thirteen groups of four 18650 cells rated 3.6 V, 3.0 Ah and 15 A give 13 × 3.6 = 46.8 V nominal (54.6 V full, 32.5 V empty) and 4 × 3.0 = 12 Ah, so 46.8 × 12 = 561.6 Wh. The pack can deliver 4 × 15 = 60 A, about 2.8 kW. The 52 cells weigh 2.50 kg, about 2.87 kg with 15 % for strip, BMS and case, and the BMS needs 14 balance wires. With 18 mΩ cells the pack resistance is 58.5 mΩ, so it sags about 3.5 V at 60 A.
Limits
Preset values are typical datasheet figures and real cells vary by brand and batch; use matched cells of the same model and age. Capacity falls at high current and low temperature, and the mass allowance is a rough estimate. The designer does not cover welding, fusing, thermal design or certification. Building lithium packs carries fire risk; it is not a substitute for training, a proper BMS and local safety rules.
Exemple concret
13S4P of 3.6 V 3.0 Ah 18650 cells = 46.8 V, 12 Ah, 561.6 Wh, 60 A, 52 cells, 14 balance wires.
L'essentiel
- Catégorie: Ingénierie et construction
- Fonctionne dans votre navigateur, sans inscription, sans envoi.
- Ce que vous saisissez reste sur votre appareil.
- Disponible en anglais.
- Contenu révisé pour la dernière fois:
- Source officielle: Battery University BU-302: series and parallel battery configurations
Questions fréquentes
What does 13S4P mean?
Thirteen groups in series, each group made of four cells in parallel. It is the usual layout of a 48 V e-bike pack built from 18650 cells.
How do I calculate pack voltage and capacity?
Voltage = number in series × cell voltage. Capacity = number in parallel × cell capacity. Energy = voltage × capacity in Wh.
How many balance wires does a BMS need?
One more than the number of series groups: a 13S pack needs 14 balance leads, from the negative end through every junction to the positive end.
Can I mix different cells in one pack?
It is strongly discouraged. Cells with different capacities or ages drift apart, the weakest cell limits the whole pack and can be overcharged or over-discharged.
Why does the pack voltage drop under load?
Every cell has internal resistance. Current through the pack's total resistance causes a voltage drop and heat, which the designer estimates from the cell resistance you enter.
Can I save several designs?
Yes. Save design keeps the cell, layout and name in the Saved designs tab; Save file exports everything as JSON.
