Pumping Test Hydraulic Conductivity Calculator

Choose Thiem confined or unconfined, Cooper-Jacob or a Hvorslev slug test, enter the test data and get K in m/day, m/s and cm/s, plus T and S.

S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho

…

Com es fa

  1. 1
    Choose the method

    Thiem, Cooper-Jacob or Hvorslev.

  2. 2
    Enter the pumping rate

    In m³/day.

  3. 3
    Enter distances and drawdowns

    From your observation wells.

  4. 4
    Read K and T

    In several units.

  5. 5
    Compare with typical values

    In the table.

Sobre aquesta eina

Hydraulic conductivity K tells how easily water moves through soil or rock. Hydrogeologists measure it in the field by pumping a well and watching water levels fall in nearby observation wells, or by suddenly changing the water level in a single well and timing the recovery. This calculator applies the four classic analysis methods taught in every hydrogeology course: the Thiem equation for confined and unconfined aquifers at steady state, the Cooper-Jacob straight-line method for transient drawdown, and the Hvorslev slug test. It reports K in m/day, m/s and cm/s, transmissivity, storativity where available, and a typical material class.

Who this is for

Hydrogeology students, groundwater consultants, well drillers, environmental engineers and anyone checking a pumping test report.

Thiem equation (confined aquifer)

At steady state, drawdown falls off with the logarithm of distance from the pumping well. With drawdowns s₁ and s₂ measured at distances r₁ and r₂, the aquifer thickness b and the pumping rate Q:

K = Q ln(r₂/r₁) / (2π b (s₁ − s₂)), and transmissivity T = K b.

Thiem-Dupuit (unconfined aquifer)

In an unconfined aquifer the saturated thickness changes with drawdown, so heads h₁ and h₂ above the aquifer base are used: K = Q ln(r₂/r₁) / (π (h₂² − h₁²)).

Cooper-Jacob straight-line method

Plot drawdown in an observation well against the logarithm of time. After early time the points fall on a straight line. Read Δs, the drawdown change over one log cycle, and t₀, where the line crosses zero drawdown. Then T = 2.303 Q / (4π Δs) and S = 2.25 T t₀ / r². The method is valid when u = r²S / (4Tt) is less than about 0.05, so use late-time data.

Hvorslev slug test

Raise or lower the water level in a well quickly (with a slug or a pump) and record recovery. Plot the normalised head on a log scale against time and read T₀, the time to reach 37 % of the initial change. For a screen length L_e, screen radius R and casing radius r_c, with L_e/R greater than 8: K = r_c² ln(L_e/R) / (2 L_e T₀).

Typical values

| Material | K (m/day) | |---|---| | clean gravel | more than 100 | | sand | 1 to 100 | | silt, fine silty sand | 0.01 to 1 | | glacial till | 10⁻⁴ to 0.01 | | clay | below 10⁻⁴ |

Units

1 m/day = 1.157 × 10⁻⁵ m/s = 1.157 × 10⁻³ cm/s. Enter Q in m³/day; 1 L/s = 86.4 m³/day.

Common pitfalls

- Using early-time data in the Cooper-Jacob method, where u is still large. - Ignoring well losses: drawdown measured inside the pumping well includes turbulent losses, so use observation wells for Thiem. - Partial penetration, boundaries and leakage all bend the drawdown curve. - Slug tests sample only the material close to the screen, often including the gravel pack and skin.

Worked example

A well pumps 1,000 m³/day from a confined aquifer 20 m thick. Observation wells at 10 m and 100 m show steady drawdowns of 3 m and 1 m. K = 1000 × ln 10 / (2π × 20 × 2) = 9.16 m/day and T = 183 m²/day, typical of a sand aquifer.

Limits

Analytical solutions for ideal homogeneous aquifers; not a substitute for type-curve analysis, numerical models or an official hydrogeological report.

Exemple resolt

Q 1,000 m³/day, drawdowns 3 m and 1 m at 10 m and 100 m in a 20 m confined aquifer give K = 9.16 m/day.

En resum

Preguntes freqüents

What is hydraulic conductivity?

The ease with which water flows through a porous material, in length per time.

What is transmissivity?

Conductivity times saturated thickness: the flow capacity of the whole aquifer.

When is Cooper-Jacob valid?

When u = r²S/(4Tt) is below about 0.05, that is at late time.

What does a slug test measure?

Conductivity near the well screen, quickly and cheaply.

How do I convert L/s to m³/day?

Multiply by 86.4.

Is my data stored?

No. Everything is calculated in your browser.