Hearing Conservation Noise Dose Calculator

List each noisy task with its level and duration, pick NIOSH or OSHA criteria and your hearing protection, and see the daily dose before and after protection.

S'executa al teu navegador. Els fitxers mai no surten del dispositiu. Mira com comprovar-ho

…

Com es fa

  1. 1
    Choose criterion

    NIOSH or OSHA.

  2. 2
    Set protection

    Type and NRR.

  3. 3
    List tasks

    Level and minutes.

  4. 4
    Read dose

    Unprotected and protected.

  5. 5
    Act

    Rotate tasks or double up.

Sobre aquesta eina

The Hearing Conservation Noise Dose Calculator works out how much of a day's safe noise allowance a mix of tasks uses up, which matters a great deal on a flight line, in a hangar or on a test cell. Enter each exposure as a row with a source, a level in dBA and the minutes spent there. The calculator finds the allowed time at each level under the criterion you choose, adds up the fractions as a daily dose, and converts the total to an 8-hour equivalent level. It then repeats the sum with your hearing protection worn, using a derated attenuation rather than the full figure on the packet, because real-world fit is rarely as good as the laboratory test. Three criteria are offered: the NIOSH style 85 dBA with a 3 dB exchange rate (close to the approach used in the EU), the OSHA permissible exposure limit of 90 dBA with 5 dB, and the OSHA 85 dBA action level with 5 dB. A reference table lists the allowed daily time at ten levels from 85 to 120 dBA.

Who this is for

Aircraft technicians and line engineers, ground handling and marshalling teams, safety and bioenvironmental staff preparing a toolbox talk, supervisors planning task rotation, and students learning how noise dose and exchange rates work.

How to use it

1. Two example days are loaded: a flight line technician under NIOSH with ear muffs, and the same tasks under the OSHA PEL with foam plugs. 2. Choose the criterion that applies to your workplace. 3. Pick the protection worn: none, ear muffs, foam plugs, other plugs, or plugs and muffs together. 4. Enter the NRR from the packet; for double protection, enter the higher of the two. 5. Choose the derating method, NIOSH percentages or the OSHA (NRR - 7) / 2 formula. 6. Edit the exposure rows with your own tasks, levels and minutes, adding or removing rows as needed. 7. Read the five figures, then the exposure table, which shows the allowed time, dose, protected level and protected dose for every task.

How the dose is calculated

Allowed time at a level L is 8 hours divided by 2 raised to (L minus the criterion) divided by the exchange rate. Under NIOSH, 85 dBA allows 8 hours, 88 dBA 4 hours and 100 dBA only about 15 minutes. Each task's dose is its duration divided by its allowed time, and the daily dose is the sum. The 8-hour equivalent is the criterion plus the exchange rate times log base 2 of the dose, so a 200% dose under NIOSH is 88 dBA.

How protection is estimated

With the NIOSH method, the NRR is cut by 25% for ear muffs, 50% for foam plugs and 70% for other plugs, then 7 dB is taken off for A-weighted levels. The OSHA method subtracts 7 and halves the result. Wearing plugs and muffs together adds 5 dB to the higher protector. The default NRR of 25 for muffs gives about 11.8 dB of estimated protection.

The default example

A technician spends 20 minutes at 110 dBA during an engine run, 90 minutes at 95 dBA beside a running APU, 4 hours at 85 dBA in the hangar and 2 hours in a 65 dBA crew room. Under NIOSH the unprotected dose is about 1,583%, an 8-hour level near 97 dBA. Even with the muffs, the protected dose is about 105%, so the notes suggest cutting time near the engine, adding plugs under the muffs or reducing noise at source.

Data handling

Exposure lists are stored only in this browser, and you can export or print them for a hearing conservation file.

Comparing options

Add a second work day with the + button to test a change, such as splitting the engine run between two people or swapping muffs for plugs and muffs together, then open Compare all to see both doses next to each other. The comparison table exports as CSV for a risk assessment.

Limits

Levels must come from a proper noise survey, and the result assumes protection is worn for the whole of every exposure. Impulse noise, ototoxic chemicals and individual susceptibility are not included. Use it to plan, not as occupational health advice; your occupational health or bioenvironmental team and local regulations set the controls.

Exemple resolt

20 min at 110 dBA, 90 min at 95, 4 h at 85 and 2 h at 65 gives about 1,583% dose (97 dBA) under NIOSH, falling to about 105% with NRR 25 muffs derated to 11.8 dB.

En resum

Preguntes freqüents

What is a noise dose?

The share of a day's allowed noise exposure you have used; 100% is the limit.

Why do NIOSH and OSHA give different answers?

NIOSH uses 85 dBA with a 3 dB exchange rate; the OSHA PEL uses 90 dBA with 5 dB, which is less protective.

Why is the NRR reduced?

Laboratory ratings overstate real-world protection, so derating allows for imperfect fit.

How is double protection handled?

The higher protector is derated and 5 dB is added.

Can I enter several tasks?

Yes, add as many exposure rows as you need.

Where do I get the dBA levels?

From a noise survey by your occupational health or bioenvironmental team.

Totalment gratisSense cost, sense registre
Els fitxers es mantenen privatsTot funciona al teu navegador
Fàcil en el teu idiomaDisponible en molts idiomes