Column Buckling Calculator (Euler and Johnson)

Enter modulus, second moment of area, area, length and end conditions to get the critical buckling load, slenderness ratio, buckling regime and the safety factor for your load.

Chạy trong trình duyệt của bạn. Tệp không bao giờ rời khỏi thiết bị. Xem cách tự kiểm tra

…

Cách thực hiện

  1. 1
    Enter E, I and A

    From a table or the section tool.

  2. 2
    Set length and ends

    Choose design or theoretical K.

  3. 3
    Add the yield strength

    Selects Euler or Johnson.

  4. 4
    Enter your load

    To get the safety factor.

  5. 5
    Check the length sweep

    How capacity drops with length.

Giới thiệu công cụ này

A slender column fails by buckling long before the material yields. Euler's formula P = π²EI/(KL)² gives the elastic critical load, where K is the effective length factor that depends on how the ends are held. For shorter, stockier columns the Euler load would exceed the yield load, and the Johnson parabola gives a more realistic critical stress. This calculator finds the radius of gyration, the slenderness ratio KL/r, the transition slenderness √(2π²E/fy), and picks the right formula. You can use the theoretical K values or the higher values recommended for design, which allow for imperfect end fixity. A what-if table shows how the critical load falls as the column gets longer.

Who this is for

Structural and mechanical engineers, students, machine designers checking struts and push rods, and anyone sizing a post or leg.

End conditions and K

| Ends | Theoretical K | Recommended design K | |---|---|---| | Pinned-pinned | 1.0 | 1.0 | | Fixed-pinned | 0.7 | 0.8 | | Fixed-fixed | 0.5 | 0.65 | | Fixed-free (flagpole) | 2.0 | 2.1 | The design values come from the AISC commentary and reflect that real connections are never perfectly rigid.

Euler or Johnson

The transition slenderness is λc = √(2π²E/fy). Above λc, the elastic Euler formula applies. Below it, the Johnson parabola σcr = fy − (fy²/(4π²E))·λ² is used, which meets the Euler curve at λc and reaches fy at zero length.

Inputs

E in GPa, I in mm⁴ (about the weak axis for an unbraced column), area A in mm², length L in mm, yield strength fy in MPa and the applied load P in kN. Get I and A from the section properties calculator or a steel table.

Worked example

An IPE 300 (Iz = 604 cm⁴ about the weak axis, A = 53.8 cm²) as a 4 m pinned column: r = 33.5 mm and λ = 119. For S355, λc = 105, so Euler applies: Pcr ≈ 745 kN. About the strong axis (Iy = 8356 cm⁴), λ = 32 and the Johnson formula gives about 1,820 kN.

Design codes

Eurocode 3 and AISC 360 use column curves that include residual stresses and initial crookedness, which give lower capacities than Euler and Johnson, and partial safety factors. Use this tool for understanding and preliminary checks, then apply the code.

Improving buckling resistance

- Shorten the unbraced length with intermediate bracing: halving the length quadruples the Euler load. - Fix the ends: going from pinned to fixed ends reduces K from 1.0 to 0.65 in design. - Move material away from the axis: a tube or box has a much larger radius of gyration than a solid bar of the same area. - Use a stiffer material only for slender columns; for stocky columns, a higher yield strength helps more.

Limits

Assumes a straight, prismatic, centrally loaded column. Local, lateral-torsional and flexural-torsional buckling are not checked. This is not professional engineering advice.

Ví dụ có lời giải

A 4 m pinned IPE 300 about its weak axis buckles at about 745 kN (Euler).

Tóm tắt

Câu hỏi thường gặp

What is the slenderness ratio?

KL/r: effective length divided by radius of gyration.

When should I use the Johnson formula?

When the slenderness is below √(2π²E/fy).

Which axis should I check?

The weaker one (smallest r), unless the column is braced in that direction.

Why are design K values higher?

Real end connections are never fully rigid.

Does it include safety factors?

No. It gives the theoretical critical load; apply your code's factors.

Is my data stored?

Only on your device, and only if you save a scenario.

Hoàn toàn miễn phíKhông phí, không đăng ký
Tệp luôn riêng tưMọi thứ chạy trong trình duyệt của bạn
Dễ dùng bằng ngôn ngữ của bạnCó nhiều ngôn ngữ