Door Rough Opening Calculator

Build a door schedule and get every rough opening, header and stud count, barn door and track sizes, warnings and a lumber list for framing.

Tarayıcınızda çalışır. Dosyalarınız cihazınızdan asla çıkmaz. Nasıl kontrol edeceğinizi görün

…

Nasıl yapılır

  1. 1
    Add doors

    In Doors, add each door with mark, type, slab size, quantity, header and jacks per side.

  2. 2
    Mark bearing walls

    Tick Bearing for doors in load-bearing walls to get header warnings.

  3. 3
    Set the wall

    Under Allowances and wall, enter wall height, plates, stud size and spacing.

  4. 4
    Check allowances

    Replace default allowances with your door maker's rough-opening numbers.

  5. 5
    Review openings

    Open Rough openings for sizes, headers, cripples and notes, and Framing sketch for any door.

  6. 6
    Order and print

    Read the Lumber list, then print the framing sheet or export CSV.

Bu araç hakkında

Framing a doorway too tight means planing a jamb or recutting studs; framing it too loose means a lot of shims and a door that never sits right. The rough opening is the framed hole, and it depends on the type of door. A prehung interior unit typically needs about 2 inches more than the slab width and about 2.5 inches more than its height, a pocket door frame kit needs a little more than twice the door width, and a barn door needs no opening change at all but a door wider than the opening and a track twice its width. This calculator keeps all of that in one schedule. Add each door with its mark, type, slab size and quantity, choose a header and the jack studs per side, and tick bearing for doors in load-bearing walls. The tool returns the rough opening width and height, the header length including the jack studs, the jack and king stud count, the number and length of cripple studs above the header for your wall height, and warnings when a header will not fit under the top plate or a bearing wall needs more support. A framing sketch shows any door to scale, and a lumber list totals headers and studs for the whole job.

Allowances you control

Every door type has a width multiplier, a width allowance and a height allowance. The defaults are common framing numbers: 2 and 2.5 inches for prehung interior doors, 2 and 2 for exterior units, a little more for a slab hung in a new jamb, twice the slab plus 1 inch and 4.5 inches of height for pocket door kits. Door and frame makers print their own rough openings, and those always win; type them into the allowance table and the whole schedule updates. A finished-floor allowance raises every opening for tile or hardwood still to come.

Headers and cripples

Header length is the rough opening plus the jack studs on each side. Cripple length is the wall height minus the top plates, the opening height and the header depth, and the count follows your stud spacing. Choose flat 2x4 headers for non-bearing partitions or deeper lumber and LVL where loads need them.

Barn and pocket doors

For a barn door you enter the finished opening and the tool adds your overlap to size the door, doubles the door width for the track and tells you how much clear wall the door slides over. Pocket doors also list the clear wall needed beside the opening.

Limits

The calculator does not size headers for loads. Headers in bearing walls must come from your building code span tables or an engineer, based on span, snow load, floors above and species. Fire doors, egress sizes and accessibility clearances follow separate rules that are not checked here.

Çözümlü örnek

A basement plan has two 32 by 80 inch bedroom doors. As prehung interior units they need rough openings of 34 by 82-1/2 inches. With one jack per side and a flat 2x4 header, the header is 37 inches long, and in a wall of 97-1/8 inches (92-5/8 inch studs on a single bottom plate and double top plate) the cripples are 10-1/8 inches long, two per door. A 30 inch pocket door needs 61 by 84-1/2 inches and 30 inches of clear wall for the pocket. A pantry with a 36 by 84 inch finished opening and 1 inch overlap takes a 38 by 85 inch barn door on a 76 inch track.

Kısaca

Sık sorulan sorular

What is the rough opening for a 36 inch prehung door?

With the common allowances it is 38 inches wide by 82-1/2 inches high for an 80 inch door. Exterior units vary more by maker, so check the installation sheet for the exact frame size.

Why is a pocket door opening so wide?

The door slides into the wall beside the opening, so the frame kit needs the door width twice plus a little for the split jambs. Most kits list a rough opening of twice the door width plus about 1 inch.

How many jack studs do I need?

Many interior openings use one per side. Wider openings in bearing walls usually need two, and your code's header table states the number. The tool warns when a bearing opening over 6 feet has only one.

Does a barn door need a rough opening?

Not a new one. It hangs on a track over a finished opening, so you size the door from the opening plus overlap and make sure there is solid backing and clear wall for the full track length.

What does the finished floor allowance do?

It adds the thickness of flooring to be installed later, so the door still clears the finished floor. Enter the total of underlayment and floor covering.

Can I work in millimetres?

Yes. Switch the units to millimetres and every size, allowance and wall setting is converted. Stock lengths change to metres.

Tamamen ücretsizÜcret yok, kayıt yok
Dosyalar gizli kalırHer şey tarayıcınızda çalışır
Kendi dilinizde kolayBirçok dilde mevcut